Astor-Bannerman CTM3 Installation Instructions Manual

Type
Installation Instructions Manual
CTM3: Manual Changing Table
Installation instructions
Advice for safe Installation
The wall must be of solid construction and load bearing, capable of
supporting 250Kg
Safe Working Load of Changing Table. (SWL) :150 kg
Select the correct Anchors before installation,
DO NOT ATTEMPT TO INSTALL USING PLASTIC WALL PLUGS AND
WOODSCREWS
Please Note: Due to the complexity of different building methods
Astor Bannerman does not supply installation xings and anchors
N.B The Changing table cannot be installed on a Gypframe™
wall with metal studs
version 3
Noggins.
For partition walls,
reinforce with 2off
noggins made from two
pieces of 4" x 2" placed
back to back, screwed
(not Nailed) in place
N.B picture shows optional guard rail
CTM3 Change
Table Installation
Position
Stud Walls with
wood supports
CTM3 Change Table
Advised installation position
To release the bed pull the
black knob outwards
Coach Screw (75mm long.)
Through Anchor
Rawl Bolt (shield anchor)
Bolts are 8mm Diameter
Installation process.
1. Unpack the unit.
2. Determine the position of the unit on the wall ensuring that the lower mounting fixing points are
at least 438mm from the floor. The range of travel for the stretcher is 290mm. If the lower fixing points
are drilled at 438mm from floor level the stretcher will operate from 790mm to 1080mm.
3. Mark the hole positions for the upper blocks carefully ensuring that the two sets of marks are level. Fix
the unit to the wall.
4. Hinge the unit upwards or remove from the fittings, then mark hole position for the lower fixings.
5. Drill full-depth holes at all four marked positions to accept your Anchors.
6. For fixing to ply only. Drill full depth pilot holes at all 4 marked positions. (8MM Ø Coach screws are
usually used for plywood).
7. Fit the CTM2 frame onto the wall and secure.
Unit 11f, Coln Park, Andoversford, Gloucestershire, GL54 4HJ
Tel 01242-820820 Fax01242-821110, e mail: [email protected]
Gap 40mm Min
Distance = 1/2 Bed Length -295mm
Hole Centres = 595mm
Hole Centres = 797mm
1262mm Recommended
1162mm Minimum