10
Ft7000 Controller PC Power SuPPly remove and rePlaCement ProCedureS
SyStem Start uP and oPeratIonal teStIng of the ft7000 Pc controller
System Start UP
Switch “On” the UPS and Power Supply to power up the terminal.
After Windows, Prism, and Kalignite load, select Option 1, Management Functions from the Pow-
er Up ATM Startup Options menu (or press Ctrl + 1 on the Rear Service Panel (RSP) keyboard).
Log into Management Functions.
IF THE CONFIGURATION PARAMETER FILE WAS NOT PREVIOUSLY “SAVED” DUE TO AN INTERNAL
CONTROLLER PC POWER SUPPLY FAILURE, PROCEED TO THE “oPerational teStinG oF tHe Ft7000”
PROCEDURE.
Restore Conguration Parameter File
Select Option 1, Display Conguration Summary and then print and verify all conguration
parameters with the previously “saved” copy. If it is necessary to restore the “saved” copy of the
conguration parameter le, move on to the next step, otherwise proceed to “Operational Testing
of the FT7000”.
Select Option 8, Terminal Status.
Select Option 3, Restore Parameters from External Storage. Make sure the USB external
storage device with the Saved Parameters has been installed at one of the Controller PC’s USB
ports.
Select Option 1, Display Conguration Summary and then print and verify all conguration pa-
rameters with the previously “saved” copy.
Operational Testing Of the FT7000
Select Option 2, Diagnostics. Run all diagnostic menu selections. Verify no error conditions ex-
ist.
Press the Ctrl key on the Rear Service Panel (RSP) keyboard and select Option 2, Exit Manage-
ment Functions to run Health Check and enter Customer Transactions.
Perform a complete online performance test from Customer Transactions.
1.
2.
3.
•
1.
2.
3.
4.
1.
2.
3.
**IMPORTANT**
As part of the FT7000 PC Power Supply Remove and Replace process, the steps
below direct the technician to copy the previously “Saved” conguration Param-
eter le from the external USB device (e.g. thumb drive) to the terminal. It may not
be necessary to copy this le back to the terminal unless the original was lost or
corrupted while servicing the FT7000.