Page 6
Gather and identify the faucet pieces.
WATTS Premier (Top Mount) Monitor Faucet Installation
Step 2
Step 3
Step 4
Step 5
Step 6
Note:
Tubing Connections
The BLUE Tube from the faucet should be connected
to the clean water source, such as from the RO system,
clean water storage tank, or from the final filter. This is
the line that supplies the faucet with clean water when the
faucet is turned to the “ON” position. You may need to use
a 3/8” to 1/4” union (Watts p/n: 125037) to attach this line.
This is also the only line to connect if your
faucet does not have an air gap.
The RED Tube from the faucet should be connected to the
waste water output port on the RO system.
The BLACK Tube from the faucet should be connected to the drain. This is a gravity fed line, if there is any bend or dip in the tube the
rinse water will not flow into the drain properly. Water may back up and come out the air gap hole in the back of the faucet base.
Check all connections for any signs of leaking over a 24 hour period.
Step 7
Watts Premier
1-800-752-5582 (USA only)
1725 W.Williams Drive C-20
623-931-1977
Phoenix, AZ 85027
Step 1
Minimum Maximum
Mounting Hole Size 1.00” 1.25”
Torque on Toggle Bolt 5lb.in. (max)
Remove the faucet battery from the plastic bag. Locate the faucet battery compartment drawer on the base of the faucet. Using a small
screwd�
drawer.
NOTE: The + side of the battery faces up. The compartment drawer will not slide in if the battery is installed upside down.
Once the battery is in place, slide the battery compartment drawer back into the base until it is flush.
When the battery is first installed, both the red and green lights will flash to indicate that both lights are functional. Thereafter, it will flash
green only when the faucet handle is turned to the “ON” position. When your system is ready to be serviced (approximately six months)
you will see the light flash red when the handle is turned to the “ON” position. Refer to the Six Month Maintenance section of your
system’s manual for filter replacement.
NOTE: If your water usage is high the red light may activate sooner than six months indicating the need for filter replacement.
Faucet Battery Installation
Watts Monitor Faucet
P/N: 116074 (Chrome Monitor with Air Gap)
P/N: 116075 (Chrome Monitor)
Remove faucet base & faucet spout from their respective
plastic bags. From above the sink, feed the faucet tubing &
toggle bolt down through the 1.00” to 1.25” mounting hole
in the sink. Ensure that the soft rubber gasket is uniformly
positioned in between the base and the top of the sink.
Align the faucet base so that the handle is on the right
side and the base is sitting flush on the sink top. Turn the
handle down (towards you) to the “ON” position to reveal the
tightening screw (located where the spout will be inserted).
Using a phillips head screwdriver, turn the screw clockwise
until the toggle bolt secures the faucet base snug onto the
sink top, do not over torque toggle bolt (5lb.in. max.).
Once the faucet base is securely fastened to the sink top,
insert the faucet spout into the faucet base until it is fully
seated. Turn the handle up (away from you) to the “OFF”
position.
Step 8
This faucet provides an electronic monitor that will tell you when it is time to replace the filters in your water treatment device. The light
indicator will be green for the life of the filter, turning red once the life of the filter has been reached. This can occur after six months of
use, or sooner for heavy water usage. To reset the electronic monitor during replacement of filters, simply slide out the battery from the
faucet and reinsert. The battery life is expected to last one year, however, for heavy use the battery may need to be replaced sooner. For
replacement, look for battery number CR2354 (Watts p/n:116082) which is available at your local battery store or contact Watts Premier at
800-752-7782. You can also order online at www.wattspremier.com.