Equinox Systems VORTEX User manual

Category
Stroboscopes & disco lights
Type
User manual
Order code: EQLED073
Vortex
User Manual
www.prolight.co.uk Vortex User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE INITIAL START-UP!
• Beforeinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.
www.prolight.co.uk Vortex User Manual
3
Product overview & technical specications
Boastingacombined120WLEDoutput,the3x40WRGBWLEDscoupledwithazoomfeatureandacontinuous
front-lensrotationoffersmobileDJsandentertainersauniquemovingheadthatcreatessuperbmid-aireffects.
The4pushbuttonOLEDmenuallowsforeasyaccesstothefunctionsincludingDMX,auto,soundactiveand
master/slavemodes.Loadedwithadvancedinternalprogrammingincludinga180degreeforwardfacingshow
whichfurtherenhancesthesoundactiveandautomodesdeliveringstunninglightshows.
•3x40Wquad-colourLEDs(RGBW)
•Adjustablebeamangle:5°-60°
•10,380Lux@2m(fullon)
•Motorisedzoom
•Pan:540°,Tilt:190°
•DMXchannels:10or17selectable
•Auto,soundactiveandmaster/slavemodes
•0-100%dimmingandvariablestrobe
•Suppliedwithquickreleaseomegaclamp
•4pushbuttonmenuwithOLEDdisplay
•PowerCONinput/output
•3-PinXLRinput/output
•Fancooled
Vortex
Specications Vortex
Powerconsumption 150W
Fuse F2A250V
Powersupply 100~240V,50/60Hz
Dimensions 360x265x175mm
Weight 6kg
Ordercode EQLED073
0m 1m 2m 3m 4m 5m
60°
5° - Lux
FULL ON
R
G
B
W
29860
5370
9809
2560
14540
120000
21500
39200
10200
58000
13300
2390
4360
1140
6440
7480
1340
2450
640
3630
4780
859
1570
410
2320
60° - Lux
FULL ON
R
G
B
W
2738
534
900
235
1270
11000
2140
3600
940
5080
1220
237
400
104
564
685
134
225
58.8
318
438
85.4
144
37.6
203
175mm
360mm
265mm
www.prolight.co.uk Vortex User Manual
4
Technical specications
01-OLEDdisplay
02-Functionbuttons
03-Microphone
04-3-PinDMXinput
05-3-PinDMXoutput
06-PowerCONinput
07-PowerCONoutput
08-FuseF2A250V
09-Fancoolingvents
Inthebox:1 x xture,
1 x omega clamp,
1 x power cable
& 1 x user manual
MENU
MIC
DOWN UP ENTER
DMX INPUT DMX OUTPUT
FUSE:
F2A 250V
POWER INPUT:
100-240V~50/60Hz
POWER OUTPUT:
100-240V~50/60Hz
www.prolight.co.uk
POWER CONSUMPTION: 150W
09
01 0203 04 05
08
06 07 09
09
www.prolight.co.uk Vortex User Manual
5
Operating instructions
Control Panel Menu:
TheOLEDcontrolpanelsituatedonthefrontofthextureallowstheusertoaccessthemenusystemto
adjustthexturessettings.Whentheunithasbeenpoweredonitwillshow“Equinox Vortex Resetting”.
Thexturewillthenreturntoitshomescreen.Toaccessthemainmenupressthe“ENTER”buttonand
usethe“UP”and“DOWN” buttonsuntilthemenurequiredishighlighted.Pressingthe“ENTER”button
ononeoftheseoptionsallowsyoutoaccessthesubmenuwhereyouusethe“UP”and“DOWN”
buttonstoselecttheoption/valuerequired.
Oncetheoption/valuehasbeenselectedpressthe“ENTER”buttononcemoretoconrmthesetting.
Main Menu Sub Menu Options/Values Description
(Default Settings in BOLD)
1.DMXAddress 001-512 DMXAddressSetting
2.RunningMODE
DMX 17 Ch(17channelmode)
DMXChannelSetting
DMX10Ch(10channelmode)
Auto AutoMode
Sound SoundMode
Slave SlaveMode
3.AutoProg Prog1-Prog04 AutoModeBuilt-inPrograms
4.Settings
PanRev
OFF
PanInverseSetting
ON
TiltRev
OFF
TiltInverseSetting
ON
DisplayRev
OFF
DisplayInverseSetting
ON
Sensitivity 000-100 SoundSensitivitySetting
SpeedMode
FASTSpeed
Pan/tiltSpeed
SlowSpeed
Calibration
AlltoOrigin
Calibration
AdjustPan 000-120
AdjustTilt 000-120
AdjustZoom 000-120
AdjustRot 000-120
AdjustRed 000-255
AdjustGreen 000-255
AdjustBlue 000-255
AdjustWhite 000-255
FactorySet
ON
FactoryReset
OFF
ResetMotor MotorReset
5.SystemInfo
SoftwareVx.xx SoftwareVersion
Mode FixturesCurrentMode
Address FixturesDMXAddress
www.prolight.co.uk Vortex User Manual
6
Operating instructions
Channel
Value Function
10 17
1 1 000-255 Panadjustment0-540°
2 000-255 Panneadjustment
2 3 000-255 Tiltadjustment0-190°
4 000-255 Tiltneadjustment
5 000-255 Pan/tiltspeed(fast-slow)
3 6 000-255 Masterdimmer(0-100%)
4 7
000-004 LEDoff
005-250 Strobe(slow-fast)
251-255 LEDon
5 8 000-255 Reddimmer(0-100%)
6 9 000-255 Greendimmer(0-100%)
7 10 000-255 Bluedimmer(0-100%)
8 11 000-255 Whitedimmer(0-100%)
9 12 000-255 Zoom(narrow-wide)
10 13
000-100 Effectlensindexing
101-133 Effectlensshake(slow-fast)
134-194 Effectlensanti-clockwiserotation(fast-slow)
195-255 Effectlensclockwiserotation(slow-fast)
14
000-010 Nofunction
011-020 Red
021-030 Green
031-040 Blue
041-050 White
051-060 PastelRed
061-070 PastelGreen
071-080 PastelBlue
081-090 Yellow
091-100 Cyan
101-110 Magenta
111-120 PastelYellow
121-130 PastelCyan
131-140 PastelMagenta
141-150 White(RGBW)
151-200 Colourchange(slow-fast)
201-247 Colourfade(slow-fast)
248-255 Colourchange(soundactivated)
DMX channel modes:
www.prolight.co.uk Vortex User Manual
7
Operating instructions
Channel
Value Function
10 17
15
000-009 Nofunction
010-039 Zoomprogram1
040-069 Zoomprogram2
070-099 Zoomprogram3
100-129 Zoomprogram4
130-159 Zoomprogram5
160-189 Zoomprogram6
190-219 Zoomprogram7
220-255 Zoomprogram8
16
000-007 Nofunction
008-060 Pan/tiltprogram1
061-100 Pan/tiltprogram2
101-140 Pan/tiltprogram3
141-180 Pan/tiltprogram4
181-255 Pan/tilt(soundactivated)
17
000-050 Nofunction
051-100 Fastspeed(10S)
101-150 Nofunction
151-200 Slowspeed(10S)
201-255 Reset(10S)
DMX channel modes cont:
www.prolight.co.uk Vortex User Manual
8
Installation
Installation:
1)BolteachclamptotheOmegabracket(s)withtheboltandlockingnutthroughoutthe
holeinthebracket.
2)FastentheOmegabracket(s)tothebottomofthemovingheadbasebyinsertingthe
quicklockfastenersintothereceivingholesinthebaseandtighten.
3)Hangthexturetothesupportthroughtheclampandsecurewiththelockingnuts.
Fastenthesafetycablethroughthebottomofthebaseandoverthesupport.
Attention:
•Alwaysensurethatthestructuretowhichyouareattachingthextureissecureandable
tosupportaweightof10timesthexturesweight.
•Alwaysuseasafetycablethatcabhold12timestheweightofthexturewheninstalling.
•Makesurethatthextureisrmlyattachedinawaythatnovibrationsormovementcould
occurduringoperation.
•Theequipmentmustbeinstalledbyprofessionalsandmustbeinstalledinanareawhere
itisoutofreachofpeopleandnoonecanpassbyorunderit.
www.prolight.co.uk Vortex User Manual
9
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
www.prolight.co.uk Vortex User Manual
10
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
www.prolight.co.uk Vortex User Manual
11
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
www.prolight.co.uk Vortex User Manual
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Equinox Systems VORTEX User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI