Ledj LEDJ211 User manual

Category
Stroboscopes & disco lights
Type
User manual

This manual is also suitable for

Order code: LEDJ211
Q Colour HEX
User Manual
www.prolight.co.uk Q Colour HEX User Manual 2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
Before your initial start-up, please make sure that there is no damage caused during transportation.
Should there be any damage, consult your dealer and do not use the equipment.
To maintain the equipment in good working condition and to ensure safe operation, it is necessary
for the user to follow the safety instructions and warning notes written in this manual.
Please note that damages caused by user modications to this equipment are not subject to warranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or property.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
Never let the power cable come into contact with other
cables. Handle the power cable and all mains voltage
connections with particular caution!
Never remove warning or informative labels from the unit.
Do not open the equipment and do not modify the unit.
Do not connect this equipment to a dimmer pack.
Do not switch the equipment on and off in short intervals,
as this will reduce the system’s life.
Only use the equipment indoors.
Do not expose to ammable sources, liquids or gases.
Always disconnect the power from the mains when
equipment is not in use or before cleaning! Only handle
the power-cable by the plug. Never pull out the plug by
pulling the power-cable.
Make sure that the available mains supply voltage is
between 100~240V AC, 50/60Hz.
Make sure that the power cable is never crimped or
damaged. Check the equipment and the power cable
periodically.
If the equipment is dropped or damaged, disconnect the
mains power supply immediately and have a qualied
engineer inspect the equipment before operating again.
If the equipment has been exposed to drastic
temperature uctuation (e.g. after transportation),
do not connect power or switch it on immediately.
The arising condensation might damage the equipment.
Leave the equipment switched off until it has reached
room temperature.
If your product fails to function correctly, stop use
immediately. Pack the unit securely (preferably in the
original packing material), and return it to your Pro Light
dealer for service.
Only use fuses of same type and rating.
Repairs, servicing and power connection must only be
carried out by a qualied technician. THIS UNIT CONTAINS
NO USER SERVICEABLE PARTS.
This lighting xture is for professional use only - it is
not designed for or suitable for household use. The
product must be installed by a qualied technician in
accordance with local territory regulations. The safety of
the installation is the responsibility of the installer. The
xture presents risks of severe injury or death due to re
hazards, electric shock and falls.
Warning! Risk Group 2 LED product according to
EN 62471. Do not view the light output with optical
instruments or any device that may concentrate the beam.
WARRANTY: One year from date of purchase.
www.prolight.co.uk Q Colour HEX User Manual 3
Product overview & technical specications
0m 1m 2m 3m 4m 5m
40° - Lux
FULL ON
R
G
B
W
A
UV
17200
3730
5920
1320
6320
2870
N/A
4305
933
1482
329
1579
718
N/A
1920
415
658
146
702
319
N/A
40°
1080
233
370
82.3
395
180
N/A
690
149
237
52.6
253
115
N/A
Utilising LED technology the Q Colour HEX adds intense colour to stages and performers. The xture has a
slim rugged chassis and provides exceptional quality, coverage and ease of use. With the ability to run built-in
programs and perform full RGBWAUV colour mixing with or without DMX control the xture is perfect for a host
of applications.
12 x 12W six-colour LEDs (RGBWAUV)
Beam angle: 40°
3,480 Lux @ 2m
3kHz refresh rate
DMX channels: 3/4/5/6/8 or 11 selectable
Static colour, colour mix, colour change, colour
fade, sound active and master/slave modes plus
built-in programs
0-100% dimming and variable strobe
Bracket allows for multiple rigging or oor standing
applications
4 push button menu with LCD display
PowerCON input/output
5-Pin XLR input/output
Fan cooled
Barn doors included
Q Colour HEX
Specications Q Colour HEX
Power consumption 137W
Power supply 100~240V, 50/60Hz
Fuse T2A 250V
Dimensions 244 x 412 x 150mm
Weight 6.3kg
Order codes LEDJ211
244mm
412mm 150mm
www.prolight.co.uk Q Colour HEX User Manual 4
Product overview & technical specicationsTechnical specications
01 - LCD display
02 - Function buttons
03 - 5-Pin DMX input
04 - 5-Pin DMX output
05 - PowerCON input
06 - PowerCON output
07 - Fuse T2A 250V
08 - Earth point
09 - Fan
10 - Hanging/oor bracket
11 - Bracket adjustable knobs
In the box: 1 x xture,
1 x barn door,
1 x power cable
& 1 x user manual
MENU ENTERDOWNUP
DMX OUTPUTDMX INPUT
COLOUR HEX
POWER OUTPUTPOWER INPUT
100-240V~50/60Hz
FUSE: T2A 250V
POWER CONSUMPTION: 137W www.prolight.co.uk
11
010403 02
11
05 06 08 09 1007
www.prolight.co.uk Q Colour HEX User Manual 5
Operating instructions
Main Menu Sub Menu Options/Values (Default Settings in Bold) Description
DMX Addr Addr: 001-512 DMX Address Setting
CH Mode
3CH (3 channel mode)
DMX Channel Setting
4CH (4 channel mode)
5CH (5 channel mode)
6CH (6 channel mode)
8CH (8 channel mode)
11CH (11 channel mode)
Master On Master Mode
Off
Slave Slave 1 Slave Mode
Slave 2
ProgMode Progm01-13 Sped=000-255 Built-in Programs
ColoMode
Red 000-255
Colour Mix Mode
Green 000-255
Blue 000-255
White 000-255
Amber 000-255
UV 000-255
ColMacro Colour01-Colour64 Colour Macros
MastDim 000-255 Master Dimmer
Sound On Sound Mode (This takes priority
over the program speed when on)
Off
Sense 001-100 (80) Sound Sensitivity Setting
DMXFail
BlackOut
DMX Fail SettingHold
Program
DimCurve
Linear
Dimming Curve Settings
Square
InSquare
S-curve
Control Panel Menu:
The LCD control panel situated on the rear of the xture allows the user to access the menu system to
adjust the xtures settings. When the unit has been powered on it will show “Update wait...” followed
by “QColour HEX”. The xture will then return to its home screen. To access the main menu press the
“MENU” button and use the “UP” and “DOWN” buttons until the menu required is highlighted.
Pressing the “ENTER” button on one of these options allows you to access the sub menu where
you use the “UP” and “DOWN” buttons to select the option/value required.
Once the option/value has been selected press the “ENTER” button once more to conrm the setting.
To exit out of any menus, press and hold the “MENU” button.
www.prolight.co.uk Q Colour HEX User Manual 6
Operating instructions
Main Menu Sub Menu Options/Values (Default Settings in Bold) Description
DimSpeed Fast Dimming Speed Setting
Smooth
LCD Off LCD Backlight
On
Balance
Red 000-255
White Balance Setting
Green 000-255
Blue 000-255
White 000-255
Amber 000-255
UV 000-255
AutoTest Testing Auto Test
Temp. ––– Fixture Temperature
Hours –––– Fixture Run Time
Factory No Factory Default Settings
Yes
Version V–.–– Software Version
3 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3 000-255 Blue (0-100%)
4 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3 000-255 Blue (0-100%)
4 000-255 White (0-100%)
5 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3 000-255 Blue (0-100%)
4 000-255 White (0-100%)
5 000-255 Amber (0-100%)
6 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3 000-255 Blue (0-100%)
4 000-255 White (0-100%)
5 000-255 Amber (0-100%)
6 000-255 UV (0-100%)
8 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3000-255 Blue (0-100%)
4 000-255 White (0-100%)
5 000-255 Amber (0-100%)
6 000-255 UV (0-100%)
7
000-031 Blackout
032-063 Open
064-095 Strobe (slow-fast)
096-127 Open
128-159 Pulse strobe (slow-fast)
160-191 Open
192-223 Random strobe (slow-fast)
224-255 Open
8 000-255 Master dimmer (0-100%)
www.prolight.co.uk Q Colour HEX User Manual 7
Operating instructions
11 channel mode:
Channel Value Function
1 000-255 Red (0-100%)
2 000-255 Green (0-100%)
3000-255 Blue (0-100%)
4 000-255 White (0-100%)
5 000-255 Amber (0-100%)
6 000-255 UV (0-100%)
7
000 No function
001-004 Colour Macro 1
005-008 Colour Macro 2
009-012 Colour Macro 3
013-016 Colour Macro 4
017-020 Colour Macro 5
021-024 Colour Macro 6
025-028 Colour Macro 7
029-032 Colour Macro 8
033-036 Colour Macro 9
037-040 Colour Macro 10
041-044 Colour Macro 11
045-048 Colour Macro 12
049-052 Colour Macro 13
053-056 Colour Macro 14
057-060 Colour Macro 15
061-064 Colour Macro 16
065-068 Colour Macro 17
069-072 Colour Macro 18
073-076 Colour Macro 19
077-080 Colour Macro 20
081-084 Colour Macro 21
085-088 Colour Macro 22
089-092 Colour Macro 23
093-096 Colour Macro 24
097-100 Colour Macro 25
101-104 Colour Macro 26
105-108 Colour Macro 27
109-112 Colour Macro 28
113-116 Colour Macro 29
117-120 Colour Macro 30
121-124 Colour Macro 31
125-128 Colour Macro 32
129-132 Colour Macro 33
Channel Value Function
7 cont.
133-136 Colour Macro 34
137-140 Colour Macro 35
141-144 Colour Macro 36
145-148 Colour Macro 37
149-152 Colour Macro 38
153-156 Colour Macro 38
157-160 Colour Macro 40
161-164 Colour Macro 41
165-168 Colour Macro 42
169-172 Colour Macro 43
173-176 Colour Macro 44
177-180 Colour Macro 45
181-184 Colour Macro 46
185-188 Colour Macro 47
189-192 Colour Macro 48
193-196 Colour Macro 49
197-200 Colour Macro 50
201-204 Colour Macro 51
205-208 Colour Macro 52
209-212 Colour Macro 53
213-216 Colour Macro 54
217-220 Colour Macro 55
221-224 Colour Macro 56
225-228 Colour Macro 57
229-232 Colour Macro 58
233-236 Colour Macro 59
237-240 Colour Macro 60
241-244 Colour Macro 61
245-248 Colour Macro 62
249-252 Colour Macro 63
253-255 Colour Macro 64
8
000-031 Blackout
032-063 Open
064-095 Strobe (slow-fast)
096-127 Open
128-159 Pulse strobe (slow-fast)
160-191 Open
192-223 Random strobe (slow-fast)
224-255 Open
9 000-255 Master dimmer (0-100%)
www.prolight.co.uk Q Colour HEX User Manual 8
Operating instructions
11 channel mode (cont.):
Channel Value Function
10
000-007 No function
008-026 Program 1 (RGB fade)
027-045 Program 2 (RGBW fade)
046-064 Program 3 (RGBA fade)
065-083 Program 4 (RGBUV fade)
084-102 Program 5 (RGBWAUV fade)
103-121 Program 6 (6 colour change)
122-140 Program 7 (12 colour change)
141-159 Program 8 (RGB fade in/out)
160-178 Program 9 (RGBW fade in/out)
179-197 Program 10 (RGBA fade in/out)
198-216 Program 11 (RGBUV fade in/out)
217-235 Program 12 (RGBWAUV fade in/out)
236-255 Program 13 (12 colour fade in/out)
11 000-255 Program speed (slow-fast)
www.prolight.co.uk Q Colour HEX User Manual 9
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each xture requires a “start address”
from 1- 512. A xture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a xture that occupies or uses 7 channels of DMX and was
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104,
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in
the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent
xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture.
DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT”
XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all xtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest
cable path possible. The order in which xtures are connected in a DMX line does not inuence the
DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in
a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,
no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This xture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit.
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output,
see images below.
Also remember that DMX cable must be daisy chained and cannot be split.
DMX setup
Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote: CABL10 – 2m CABL11 – 5m CABL12 – 10m3-Pin:
CABL185 – 2m CABL187 – 5m CABL188 – 10m5-Pin:
www.prolight.co.uk Q Colour HEX User Manual 10
Notice:
Be sure to follow the diagrams below when making your own cables.
Do not connect the cables shield conductor to the ground lug or
allow the shield conductor to come in contact with the XLRs
outer casing. Grounding the shield could cause a short circuit
and erratic behaviour.
Line termination:
When longer runs of cable are used,
you may need to use a terminator on
the last unit to avoid erratic behaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90,
5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR xtures
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
Termination reduces signal
transmission problems and
interference. It is always
advisable to connect a DMX
terminal, (resistance 120
Ohm 1/4W) between pin 2
(DMX-) and pin 3 (DMX+) of
the last xture.
5-Pin
1
2 4
5
3
3-Pin
1 2
3
Pin Conguration
3-Pin 5-Pin
Pin 1 - Ground
Pin 2 - Negative
Pin 3 - Positive
Pin 4 - N/C
Pin 5 - N/C
1
2
3
1
2
3
DMX 512
3-Pin XLR output
DMX 512
3-Pin XLR input
GROUND
DMX +
DMX –
DMX 512
5-Pin XLR output
DMX 512
5-Pin XLR input
1
2
45
3
12
4
5
3
GROUND
N/C
DMX –
N/C DMX +
1 ground
3 hot
2 cold
3-Pin XLR male 3-Pin XLR female
2 cold
3 hot
1 ground
2 cold
1 ground 5 N/C
3 hot 4 N/C
5-Pin XLR male 5-Pin XLR female
4 N/C
5 N/C 1 ground
3 hot 2 cold
www.prolight.co.uk Q Colour HEX User Manual 11
Multiple xture power linking
Power linking:
This xture provides power linking via the power output on the rear allowing multiple units to be
connected together. The maximum number of xtures that can be connected is 16 xtures @ 240V
or 8 xtures @ 120V (including the rst xture). After the maximum number of xtures are
connected a new power run will need to be started.
Please note: Caution should be used when power linking other xtures to the Q Colour HEX as the power
consumption of other xtures will vary. Fixtures tted with lamps often require 2/3 times more current
on startup, these may require their own power source.
MENU ENTERDOWNUP
DMX OUTPUTDMX INPUT
COLOUR HEX
POWER OUTPUTPOWER INPUT
100-240V~50/60Hz
FUSE: T2A 250V
POWER CONSUMPTION: 137W www.prolight.co.uk
MENU ENTERDOWNUP
DMX OUTPUTDMX INPUT
COLOUR HEX
POWER OUTPUTPOWER INPUT
100-240V~50/60Hz
FUSE: T2A 250V
POWER CONSUMPTION: 137W www.prolight.co.uk
www.prolight.co.uk Q Colour HEX User Manual 12
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed of
with other household wastes at the end of its working life. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, please separate this from other
types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government ofce, for details of where and how they can take this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the
purchase contract. This product should not be mixed with other commercial wastes for disposal.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Ledj LEDJ211 User manual

Category
Stroboscopes & disco lights
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI