CTC Union V22 Installation and Maintenance Manual

Type
Installation and Maintenance Manual

This manual is also suitable for

Providing sustainable energy solutions worldwide
162 105 21-3 2016-04-25
Installation and Maintenance Manual
CTC V22
CTC V40
IMPORTANT
READ CAREFULLY BEFORE USE
KEEP FOR FUTURE REFERENCE
Check the following on every firing:
!
NOTE! Firing with the doors open (Fill door/Ash door) is strictly prohibited! This
can seriously damage the boiler and cause flue gases to leak out.
Check that the sealant strip on the fill door is in tact. If
not, replace it. The boiler must not be lit with a damaged
strip.
Check the ash level in the hearth, ash must be removed
once it reaches the primary air intake in the hearth plates.
Ensure that the ash door is fully closed.
After ignition and filling with firewood, check that
the fill door is fully closed.
Check that the “Door open” message is no longer
displayed when the fill door is closed. If it is, the
inductive sensor should be adjusted.
Door open
Operation
Installation and Maintenance Manual
CTC V22
CTC V40
162 105 21-3 2016-04-25
4
CTC V22/V40
General Information
Table of Contents
GENERAL INFORMATION
FOR THE PROPERTY OWNER
Checklist ______________________________________ 6
Important to remember! _________________________ 7
Safety Instructions _____________________________ 7
1. Technical data ____________________________11
1.1 Technical data _____________________________ 11
1.2 Dimensional drawing ________________________ 12
1.3 Detailed overview ___________________________ 13
2. Firing _____________________________________14
2.1 Reverse burning ____________________________ 14
2.2 Fuel ______________________________________ 15
2.3 Air setting _________________________________ 15
2.4 Stoking ___________________________________ 16
2.5 Heating phase _____________________________ 17
2.6 Wood charging ____________________________ 17
2.7 Shutdown _________________________________ 17
2.8 Airborne noise _____________________________ 17
3. Instrument panel __________________________19
3.1 The Control Panel __________________________ 19
4. Control System____________________________20
4.1 Menu overview _____________________________ 20
4.2 Detail Description Menus ____________________ 22
4.3 Factory values _____________________________ 22
4.4 Main menu/Standard display menu ____________ 22
4.5 Time setting _______________________________ 23
4.6 Menu _____________________________________ 23
4.7 Room temperature (Lambda only) _____________ 24
4.8 Operating data _____________________________ 25
4.9 Stored operation data _______________________ 26
4.10 Night reduction (Lambda only) ________________ 27
4.11 Day by day (Lambda only) ___________________ 28
4.12 Block (Lambda only) ________________________ 28
4.13 Reset alarm/message. ______________________ 29
4.14 Alarm info _________________________________ 30
5. Maintenance ______________________________ 31
5.1 General ___________________________________ 31
5.2 Safety valves ______________________________ 31
5.3 Expansion system __________________________ 31
5.4 Flue gas fan _______________________________ 31
5.5 Replacement ______________________________ 31
6. Sweeping _________________________________32
6.1 General ___________________________________ 32
6.2 Lever sweeping (Lambda only) _______________ 33
6.3 Ash raking _________________________________ 33
6.4 Sweeping of heat transfer tube _______________ 33
FOR THE INSTALLER
7. Boiler room and chimney ___________________34
7.1 Boiler room ________________________________ 34
7.2 Wood supply ______________________________ 34
7.3 Doors ____________________________________ 35
7.4 Removal of doors: __________________________ 36
7.5 Installation of doors: ________________________ 36
7.6 Chimney __________________________________ 37
7.7 Flue pipe connection ________________________ 37
7.8 Chimney connection ________________________ 37
8. Pipe installation ___________________________38
8.1 General ___________________________________ 38
8.2 Connecting to accumulator __________________ 38
8.3 Pipe installation ____________________________ 38
8.4 Expansion system __________________________ 39
8.5 Safety valve boiler __________________________ 39
8.6 Sensor and thermal valve ____________________ 39
8.7 Cleaning door ______________________________ 39
8.8 Schematic diagram for system with charge group 40
9. Electrical installation _______________________41
9.1 General ___________________________________ 41
9.2 Accessories _______________________________ 42
9.3 Setting after electrical installation ______________ 45
9.4 Electrical diagram __________________________ 46
10. Control System____________________________48
10.1 Installer ___________________________________ 48
10.2 Settings ___________________________________ 48
10.3 Settings boiler _____________________________ 49
10.4 Setting tank charge _________________________ 49
10.5 Settings DHW/managing conduits ____________ 50
10.6 Settings addheat ___________________________ 50
10.7 Setting Heat circ. (Lambda only) ______________ 50
10.8 Heating circuit (Lambda only) _________________ 51
10.9 Service ___________________________________ 52
10.10 Function test ______________________________ 52
10.11 Factory settings coded ______________________ 53
10.12 Alarm and information texts __________________ 54
11. Resistances for sensors ____________________55
12. Declaration of Conformity __________________56
5 CTC V22/V40
For the property owner
Congratulations on buying your new product
You have chosen a CTC V22/V40 wood boiler, which we
hope you will be very pleased with.
CTC V22/V40 is available in two sizes. The lambda
model has automatic control of the air supply, the other
model has a manual air supply.
Both boilers have powerful suction fans which provide
good combustion with low emissions. The effi ciency is
over 90%.
On the lambda model sweeping is easily performed with
a lever, so called lever sweeping.
The best system function is achieved by using a charge
group and mixing valve groups which control what
should be heated or which areas should be heated.
The boiler is designed to be burning to accumulators
and must therefore not be connected for burning directly
to a radiator system.
Quick reference
Fill in the information below. It may come in useful if anything should happen.
Product: Manufacturing number:
Installer: Name
Date Tel. no.:
Electrical installer: Name
Date Tel. no.:
Master chimney sweep: Name
Date Tel. no.:
6
CTC V22/V40
For the property owner
Checklist
The check list must be completed by the installer.
In the event of a service, this information may be called for.
Installation must always be done according to the installation and maintenance instructions.
Installation must always be carried out in a professional manner.
Following installation, the unit should be inspected and checked for functionality.
The points below should be checked off.
Pipe installation
Boiler filled, positioned and adjusted in the correct manner according to the instructions.
Boiler placed so fan replacement and other servicing can be performed.
Correct pipe routing so service and cleaning apertures are not blocked.
Size of expansion vessel; open approx. 5 % of water volume; closed approx. 10 % of water volume.
Reprogramming of charge pump or charging system
Correct pipe dimensions between boiler and tanks; see Installation and Maintenance Instructions.
Right oxygen valve for overheating protection
Tightness test.
Bleed the system.
Safety valve function test.
Residual water piping runs from the oxygen outlet and safety valve to the drainage.
Electrical installation
Main switch installed
Check/program the control at start, so that the system operates in the intended way (see Installation and Maintenance
Instructions) and according to the customer's wishes.
Master chimney sweep
The flue is seal-tested and approved for firing.
Check the flue draw.
Information for the customer (adapted to current installation)
Start-up with customer/installer.
Menus/controls for selected system
Installation and maintenance manual supplied to the customer
Checks and filling, heating system
Alarm information
Mixing valve
Safety valve function test
Guarantee and insurance
Information on procedures for fault registration
!
If these instructions are not followed when installing, operating and maintaining the
system, Enertech’s commitment under the applicable warranty terms is not binding
7
CTC V22/V40
For the property owner
Important to remember!
Check the following points in particular at the time of delivery and
installation:
CTC V22/V40 must be transported and stored in an upright position.
Remove the packaging and check before installation that the product
has not been damaged in transit. Report any transport damage to the
carrier.
Place the CTC V22/V40 on a solid foundation, preferably made of
concrete.
Remember to leave a service area of at least 1 m in front of the
product.
This appliance is not intended for use by persons ( including children
) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Safety Instructions
The following safety instructions should be followed when handling,
installing and using the CTC V22/V40:
Carefully read through this instruction manual.
Do not rinse off CTC V22/V40 with water.
When handling the product with a hoist ring or similar device, make
sure that the lifting equipment, eyebolts, etc. are not damaged. Never
stand under the hoisted product.
Never jeopardize safety by removing bolted covers, hoods or similar.
Never jeopardize safety by deactivating safety equipment.
Any work on the product should be done by authorised personnel only.
Safety valve check:
The safety valve for the boiler/system and hot tap water should be
checked regularly.
Do not open the fill door when the boiler has reached its maximum
temperature or when the maximum flue gas temperature has been
reached, as there is a risk of combustion of flue gases in the hearth.
If the fill door is opened during firing, smoke and flare-ups may escape
into the room.
Do not open the ash door during operation.
!
Close the safety
switch before doing
any work on the
product.
Standard
delivery
Angle flue pipe complete
Sweeping tools for the boiler
Drainage valve
2 x Room sensor*
2 x Primary flow sensor*
2 x Tank sensor*
Outdoor sensor*
* Lambda only
8
CTC V22/V40
For the property owner
Your home's heating installation
!
The set heating curve is always given priority. The room sensor can only increase
or decrease the compensated flow temperature to a certain extent above the set
heating curve. Where operating without a room sensor, the selected heating curve
determines the flow temperature supplied to the radiators purely from the outside
temperature reading.
The House Heating Curve
The heating curve is the central part of the product’s control system. It is the heating
curve which determines the compensated flow temperature requirements for your
property dependent upon the outdoor temperatures. It is important that the heating
curve is correctly adjusted, so that you achieve the best operation and economy
possible.
One property requires a radiator temperature of 30°C when the outdoor temperature
is 0°C, whilst a different property requires 40°C. The difference between different
properties is determined by the radiator surface area, the number of radiators and how
well insulated the house is.
Adjustment of Default Values for the Heating Curve
You define the heating curve yourself for your property by setting two values in
the product control system. This is achieved by selecting the options Inclination or
Adjustment under the Installer/Settings/Radiator system menu. Ask your installer to
help you set these values.
It is extremely important to set the heating curve and, in some cases, unfortunately,
this process may take several weeks. The best way of doing this, upon the initial
start-up, is to select operation without any room sensor. The system then operates
using the outdoor temperature reading and the property’s heating curve only.
During the adjustment period it is important that:
the night reduction function is not selected.
all thermostat valves on the radiators be fully opened.
the outdoor temperature is not higher than +5°C. (If the outdoor temperature is
higher when the system is installed, use the factory set curve until the outdoor
temperature falls to a suitable level.)
the radiator system is operational and correctly adjusted between different
circuits.
Appropriate Default Values
During installation you can seldom achieve a precise setting for the heating
curve instantly. In this case, the values given below may provide a good starting
point. Radiators with small heat-emission surfaces require a higher primary flow
temperature. You can adjust the gradient (heating curve gradient) for your heating
system under the Installer/Settings/Radiator system menu.
Recommended values are:
Floor heating only Inclination 35
Low temperature system (well insulated houses) Inclination 40
Normal temperature system (factory setting) Inclination 50
High temperature system
(older houses, small radiators, poorly insulated) Inclination 60
Adjusting the heating curve
The method described below can be used to adjust the heating curve correctly.
Adjustment if it is too cold indoors
If the outdoor temperature is lower than 0 degrees:
Increase the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
If the outdoor temperature is higher than 0 degrees:
Increase the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
Adjustment if it is too warm indoors
If the outdoor temperature is lower than 0 degrees:
Decrease the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
If the outdoor temperature is higher than 0 degrees:
Decrease the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
!
If the values set are too low, this may mean that the desired room temperature
is not being reached. You then need to adjust the heating curve, as necessary,
following the method shown above.
When the basic values have been set more or less correctly, the curve can be
finely adjusted directly using the Room temp. shown on the home menu screen.
Description of inclination and adjustment
Inclination 50:
The value set is the outgoing temperature of the water supplied to the radiators at an
outdoor temperature of –15°C, e.g. 50°C. A lower value is selected where a radiator
system has large radiator areas (a low temperature system). Floor heating systems
require low temperatures. A low value should therefore be selected. The value must be
increased for high temperature systems to achieve a high enough indoor temperature.
Adjustment 0:
The adjustment means that the flow temperature can be raised or lowered at a specific
outdoor temperature.
Adjustment 0 means 50°C primary flow when the outside temperature is -15°C.
Adjustment -5 means 45°C primary flow when the outside temperature is -15°C.
For example:
Inclination 50 means that the temperature of the water supplied to the radiators will
be 50°C when the outdoor temperature is –15°C (if adjustment is set to 0). If the
adjustment is set to +5, the temperature will be 55°C instead. The curve is increased
by 5°C at all temperatures, i.e. it is parallel displaced by 5°C.
9
CTC V22/V40
For the property owner
Your home's heating installation
!
The set heating curve is always given priority. The room sensor can only increase
or decrease the compensated flow temperature to a certain extent above the set
heating curve. Where operating without a room sensor, the selected heating curve
determines the flow temperature supplied to the radiators purely from the outside
temperature reading.
The House Heating Curve
The heating curve is the central part of the product’s control system. It is the heating
curve which determines the compensated flow temperature requirements for your
property dependent upon the outdoor temperatures. It is important that the heating
curve is correctly adjusted, so that you achieve the best operation and economy
possible.
One property requires a radiator temperature of 30°C when the outdoor temperature
is 0°C, whilst a different property requires 40°C. The difference between different
properties is determined by the radiator surface area, the number of radiators and how
well insulated the house is.
Adjustment of Default Values for the Heating Curve
You define the heating curve yourself for your property by setting two values in
the product control system. This is achieved by selecting the options Inclination or
Adjustment under the Installer/Settings/Radiator system menu. Ask your installer to
help you set these values.
It is extremely important to set the heating curve and, in some cases, unfortunately,
this process may take several weeks. The best way of doing this, upon the initial
start-up, is to select operation without any room sensor. The system then operates
using the outdoor temperature reading and the property’s heating curve only.
During the adjustment period it is important that:
the night reduction function is not selected.
all thermostat valves on the radiators be fully opened.
the outdoor temperature is not higher than +5°C. (If the outdoor temperature is
higher when the system is installed, use the factory set curve until the outdoor
temperature falls to a suitable level.)
the radiator system is operational and correctly adjusted between different
circuits.
Appropriate Default Values
During installation you can seldom achieve a precise setting for the heating
curve instantly. In this case, the values given below may provide a good starting
point. Radiators with small heat-emission surfaces require a higher primary flow
temperature. You can adjust the gradient (heating curve gradient) for your heating
system under the Installer/Settings/Radiator system menu.
Recommended values are:
Floor heating only Inclination 35
Low temperature system (well insulated houses) Inclination 40
Normal temperature system (factory setting) Inclination 50
High temperature system
(older houses, small radiators, poorly insulated) Inclination 60
Adjusting the heating curve
The method described below can be used to adjust the heating curve correctly.
Adjustment if it is too cold indoors
If the outdoor temperature is lower than 0 degrees:
Increase the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
If the outdoor temperature is higher than 0 degrees:
Increase the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
Adjustment if it is too warm indoors
If the outdoor temperature is lower than 0 degrees:
Decrease the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
If the outdoor temperature is higher than 0 degrees:
Decrease the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
!
If the values set are too low, this may mean that the desired room temperature
is not being reached. You then need to adjust the heating curve, as necessary,
following the method shown above.
When the basic values have been set more or less correctly, the curve can be
finely adjusted directly using the Room temp. shown on the home menu screen.
Description of inclination and adjustment
Inclination 50:
The value set is the outgoing temperature of the water supplied to the radiators at an
outdoor temperature of –15°C, e.g. 50°C. A lower value is selected where a radiator
system has large radiator areas (a low temperature system). Floor heating systems
require low temperatures. A low value should therefore be selected. The value must be
increased for high temperature systems to achieve a high enough indoor temperature.
Adjustment 0:
The adjustment means that the flow temperature can be raised or lowered at a specific
outdoor temperature.
Adjustment 0 means 50°C primary flow when the outside temperature is -15°C.
Adjustment -5 means 45°C primary flow when the outside temperature is -15°C.
For example:
Inclination 50 means that the temperature of the water supplied to the radiators will
be 50°C when the outdoor temperature is –15°C (if adjustment is set to 0). If the
adjustment is set to +5, the temperature will be 55°C instead. The curve is increased
by 5°C at all temperatures, i.e. it is parallel displaced by 5°C.
10
CTC V22/V40
For the property owner
Examples of Heating Curves
You can see in the diagram below how the heating curve
changes with different Inclination settings. The gradient of
the curve shows the temperatures that the radiators require
at different outdoor temperatures.
Curve Inclination
The inclination value which is set is the primary flow
temperature when the outside temperature is –15°C.
Primary Flow Temperature
Primary Flow Temperature
Primary Flow Temperature
Primary Flow Temperature
Outside Temperature
Outside Temperature
Outside Temperature
Heating off, out
Heating off, out
Heating off, out
Outside Temperature
Adjustment
The curve can be parallel displaced (adjusted) by the
desired number of degrees to adapt to different systems/
houses.
An example
Inclination 60°C
Adjustment 0°C
In this example, the maximum outgoing primary flow
temperature is set at 55°C.
The minimum permitted primary flow temperature is 27°C
(e.g. summer-time basement heating or the floor circuits in
a bathroom).
Summer-time operation
All properties have internal heat gains (lamps, oven,
personal heat etc.), which means that the heating can be
switched off when the outdoor temperature is lower than
the desired room temperature. The better insulated the
house is, the earlier the heating from the heat pump can be
switched off.
The example shows the product set at the default value of
18°C. This Heating off value can be changed under the
Installer/Settings/Radiator system menu.
When the heat is switched off in this way, the radiator
pump stops and the mixing valve is shut down. The heating
starts up automatically when it is required again.
Inclination 50°C
Adjustment +5°C
Inclination 50°C
Adjustment 0°C
11
CTC V22/V40
For the property owner
!
When selecting the group fuse size, the loads connected to the main board
and the expansion board should be included. For available options, see the
wiring diagram.
1. Technical data
1.1 Technical data
V22 Lambda V40 Lambda V40
kW 22 40
liter 138
mm 370 x 680 x 549
mm 380 x 302
bar 3
°C 110
liter 114 105
kg 460 470
mbar 0.15-0.30 (15-30 Pa)
mm 120-200 150-200
°C max. 230
°C 165
kg/s 0.012 0.026 0.030
mbar 21 20
°C 55
°C 25
5
liter 1500-2000 2000-3000
bar 2.0
l/h 1000
kWh ≈125
h ≈5 ≈3
230V 1N~
W/A 159/0,69
W/A 14/0,06
IPX1
dB 56
Average output
Hearth volume
Hearth measurements (w x h x d)
Fill door (w x h)
Max. operating pressure (PS)
Max. operating temperature (TS)
Water volume (V)
Weight (excl. wrapping).
Rec. chimney draught
Rec. chimney diameter
Flue gas temperature
1)
Flue gas temperature factory setting
2)
Flue gas quantity
Pressure drop water side ∆T = 10K
Min. return temperature return pipe charge group
Min. return temperature return pipe charging pump
Boiler class in accordance with EN 303-5 class
Rec. accumulator volume
Min. connection pressure for cooling coil
Min. water quantity for cooling coil
Produced energy (at 20% humidity, full inlay of birch)
Burning time (at 20% humidity, full inlay of birch)
Electrical connection
Rated power/current
Stand by power/current
IP class
Sound power dB
1)
Max. limitation in the control system.
2)
The boiler is delivered with a factory-set fl ue gas temperature of 165 °C.
This can be changed in the ”Coded” menu where the fl ue gas temperature can be adjusted between 100-190 ºC.
Make sure that the fl ue gas temperature in the chimney is not below 70 ºC 1 meter down, to avoid condensation.
Examples of Heating Curves
You can see in the diagram below how the heating curve
changes with different Inclination settings. The gradient of
the curve shows the temperatures that the radiators require
at different outdoor temperatures.
Curve Inclination
The inclination value which is set is the primary flow
temperature when the outside temperature is –15°C.
Primary Flow Temperature
Primary Flow Temperature
Primary Flow Temperature
Primary Flow Temperature
Outside Temperature
Outside Temperature
Outside Temperature
Heating off, out
Heating off, out
Heating off, out
Outside Temperature
Adjustment
The curve can be parallel displaced (adjusted) by the
desired number of degrees to adapt to different systems/
houses.
An example
Inclination 60°C
Adjustment 0°C
In this example, the maximum outgoing primary flow
temperature is set at 55°C.
The minimum permitted primary flow temperature is 27°C
(e.g. summer-time basement heating or the floor circuits in
a bathroom).
Summer-time operation
All properties have internal heat gains (lamps, oven,
personal heat etc.), which means that the heating can be
switched off when the outdoor temperature is lower than
the desired room temperature. The better insulated the
house is, the earlier the heating from the heat pump can be
switched off.
The example shows the product set at the default value of
18°C. This Heating off value can be changed under the
Installer/Settings/Radiator system menu.
When the heat is switched off in this way, the radiator
pump stops and the mixing valve is shut down. The heating
starts up automatically when it is required again.
Inclination 50°C
Adjustment +5°C
Inclination 50°C
Adjustment 0°C
12
CTC V22/V40
For the property owner
1.2 Dimensional drawing
1. Primary flow accumulator tank Rp 1 1/4"
2. Return accumulator tank Rp 1 1/4" (charge group system)
3. Return accumulator tank Rp 1 1/4" (charging pump system)
4. Connection Ø22 cooling coil
5. Connection drainage Rp 1/2"
6. Connection flue pipe Ø150
7. Sleeve ¾" thermal valve
1450
1342
596 100 66 944
110
175 815
298
3
2
?
5
166
60
547
382
411
38
1
7
6
4
Ändr. meddel.
Datum
Nr
Ändring
Ändr. av
Kontr. av
E
art. nr
Utgåva
Ämnes nr
Ersätter
art. nr
Ersättes av
Grupp
Produkt
Reg. nr
Benämning
Tol.system
Kontr.
Normgr.
Skala
Ritad
Material
Datum
Sign.
Distr till/Antal
Ytjämnhet RA
Godk. prod
Om ej annat angives gäller ovanstående
Denna ritning är Enertech AB's egendom.
Den får ej användas till skada för
företagets intressen.
Diese Zeichnung ist das Eigentum der
Enertech AB und darf nicht zum Scha-
den dieser Gesellschaft verwendet
werden.
This drawing is the property of
Enertech AB and is not to be used
against the interest of this com-
pany
1:10
SJ
2012-12-10
Måttskiss
CTC V40
2586190
blad 1/1
13
CTC V22/V40
For the property owner
1.3 Detailed overview
1. Ash tray
2. Secondary air
3. Primary air
4. Ash door
5. Handle
6. Fill door
7. Primary flow pipe
8. Cleaning door
9. Cooling coil
10. Flue gas pipe
11. Return pipe (charge pump)
12. Fire box
13. Return pipe (charge group)
14. Draining the tank
15. Cast steel grate
16. After-fire surface
17. Ceramics
18. Start button
19. Display
20. Electrical system
21. Electrical connection
22. Turbulator
23. Lever sweeping
24. Sleeve thermal valve
25. Inductive sensor (indicates door
closing)
13
15
16
17
12
11
10
21
9
7
20
18
19
25
8
5
6
5
4
3
2
1
14
23
22
24
1. Seal, secondary air intake
2. Cast steel grate
3. Rear ceramic grate
4. Front ceramic grate
5. Front combustion chamber block
6. Rear combustion chamber block
7. Silica fibre braid Ø15 mm
8. Glass fibre braid Ø20 mm
9. Throttle insert
1
4
5
6
2
3
9
8
7
2
(image concerns V40)
14
CTC V22/V40
For the property owner
!
If the boiler is powered on, and the fill door is open,
the fan operates at maximum speed.
2. Firing
2.1 Reverse burning
The combustion must last during a sufficiently long time, at sufficiently high
temperature and at sufficient turbulence. This condition, time, temperature
and turbulence is often called the 3 Ts. A good mixture of these three
provides good combustion.
The flue gas fan ensures that the flame finds its way down the grate, and
with the help of a control flue the flame starts rotating. The fan sucks the
air and the flame on through the ceramics where the remaining gases are
burned. The air continues through the heat transfer pipes and out through
the chimney.
15
CTC V22/V40
For the property owner
!
It is both inappropriate and prohibited to heat with waste, chip boards, painted
wood, pressure-impregnated wood or similar, as these materials emit gases
which are very corrosive and hazardous when heated
V40 factory setting:
Primary air setting: 7
Secondary air setting: 4
2.2 Fuel
Moisture content, type, size and cut of the wood is of importance for
burning and for the operation of the boiler, among other things the
output.
Suitable moisture content is about 15–25%. Higher moisture content
gives lower output and lower efficiency.
The wood should be stored under roof or rain cover. The drier the
surrounding air is, the quicker the wood dries.
The boiler is designed for 0.5 m wood and it is important that the wood
be cut. Large, round logs do not dry as well and are therefore less
suitable as fuel. Suitable piece size is when 3–6 logs can be placed next
to each other in the hearth.
2.3 Air setting
CTC V22/V40 with Lambda probe automatically sets itself for best
burning with both primary and secondary air settings.
For CTC V40 without Lambda probe the property owner sets the
primary and secondary air settings. The primary and secondary air
settings are set at the factory at an average value which corresponds
with most wood types and moisture contents.
With two dampers, the primary and secondary air can be set in intervals
between of 3 and 7 for desired combustion. Adjustment of the inlet air is
primarily done depending on the moisture content of the wood.
The CTC V22 boiler supplies approximately 22 kW in ≈5 hours when
firing with birch wood with 20% moisture content.
The CTC V40 boiler supplies approximately 40 kW in ≈2.5 hours when
firing with birch wood with 20% moisture content.
Make sure that the flue gas temperature in the chimney is not below
70ºC, 1 meter down, to avoid condensation.
For damp/roughly chopped wood:
Increase the primary air setting.
For dry/finely chopped wood:
Reduce the primary air setting.
The smoke should always have a transparent, light grey nuance.
15 - 25%
50 cm
16
CTC V22/V40
For the property owner
!
At delivery the ceramics are not completely dried out. This is done at the first fir-
ing. Therefore, during the first two hours, fire very carefully with small wood inlays
only.
!
Too much wood gets the boiler up to max. temperature and the fan stops. This
can provide undesirable emissions and possible cooling of the boiler with the
cooling coil cooling the boiler without the possibility of benefiting from this heat.
!
Appropriate quantity of wood means that, when the accumulator tanks are fully
charged, the wood in the boiler has all burned up. The warning High PT means
that there is too much wood.
!
It is important that, when loading the logs, you stack them as tightly as possible,
partly because you then get in more logs and can utilize the boiler maximally,
partly because you get more even and environmentally friendly combustion with
tightly stacked logs.
!
Plan the heating and wood inlay so that you utilise the boiler and the accumulator
system maximally.
2.4 Stoking
In order to get a good combustion, the moisture content of the wood is
important. There are two alternative ways to start combustion.
Alternative 1
1. Press the start button.
2. Open the door.
3. Fill with wood so that the bottom is covered with finely chopped wood.
Cover with newspaper. Make a small newspaper “fuse” with which to
light. Cover with another layer of finely chopped wood. Continue to fill
on logs to a sufficient quantity.
4. Light.
5. Close the door.
Alternative 2
1. Open the door.
2. Fill with starting wood/sticks and add newspaper. Continue to fill with a
few logs.
3. Light.
4. Press the start button, close the door and wait a few minutes in order to
get an ember bed.
5. Open the door and fill the boiler with wood to the suitable quantity.
6. Close the door.
17
CTC V22/V40
For the property owner
!
Do not open the fill door when the boiler has reached its maximum temperature
or when the maximum flue gas temperature has been reached, as there is a risk
of combustion of flue gases in the hearth.
!
Any embers in the ashes could ignite. Always
store ashes in a safe manner
!
The ash door must
not be opened
during heating
2.5 Heating phase
For CTC V22/V40 Lambda: after filling with the appropriate amount
of wood, the control system of the boiler monitors the heating fully
automatically.
For CTC V40: The air is set before lighting. The ash door must not be
opened during heating.
2.6 Wood charging
Wood is charged as needed.
If the boiler is in the “Shutdown” phase and wood must be charged, start by
pressing the start button and the boiler will enter the “Stoking phase”.
If the fill door is opened during firing, smoke and flare-ups may escape into
the room. Open the door a couple of centimetres and wait until the fan turns
quicker before opening the door completely.
2.7 Shutdown
When the wood has burned up, the output decreases and the flue gas
temperature drops. When the flue gas temperature drops to set value, the
fan and the charge group/charging pump stop.
2.8 Airborne noise
Airborne noise originate from the flue gas fan. Normally the boiler room is
suited for heating products with a certain noise level. If the noise level is
disturbing noise damping material can be used in the boiler room to lower
the noise level. Do pay attention to distanses to the boiler and use non
burning material. If outdoor noise has to be reduced, use intended flue gas
noise damper.
18
CTC V22/V40
For the property owner
19
CTC V22/V40
For the property owner
OK
A
C
D
B
E
F
3. Instrument panel
3.1 The Control Panel
All settings are made on the easy-to-read control panel which also gives
information on operation and temperatures. The information is displayed in
a display window. With a few buttons you easily access all information by
selecting from a number of different menus.
Using the buttons
You can easily enter the different menus to find information on the operation
or to set your own values.
A.
The display window
Menu
Room temp °C 21.6 (21.5)
Operating data
Stored operating data
Night reduction
Installer
1
2
3
5
4
B. The “backspace” or “undo” button
With this button you go one step back in the menu
system to the previous menu.
You can also undo a
selection of a line.
C.
The “OK” button
With this button you accept/confirm a value or a
selection.
D.
The “increase” or “decrease” button
Here you increase or decrease a value. You can
also move the cursor one line up or down.
E.
The “Reset alarm” button
With this button you reset the product after an
alarm.
It is displayed in an alarm situation only.
F.
Start button
With this button you start the fan.
1.
Menu name
The name of the menu you currently use is shown
here. If you are not in the menu system, the product
name, week day and time (default display) are
shown.
2.
Cursor
The cursor is moved up or down to the line you
want to select. The cursor is moved with the
"increase" and "decrease" button (D). The cursor is
blackened when a line is selected. Push the “undo
button” (B) to deselect.
3.
Indication “more lines” down
The arrow indicates that there are more lines down-
wards which are not visible. Press the arrow to go
down and see more lines. The arrow disappears
when there are no more lines.
4.
Indication “more lines” up
The arrow indicates that there are more lines up-
wards which are not visible. Press the arrow to go
up and see more lines. The arrow disappears when
there are no more lines.
5.
Information area
Here information, temperatures, values, etc. are
displayed.
20
CTC V22/V40
For the property owner
4. Control System
4.1 Menu overview
86
165
30
5.9 (6.0)
75
44
86
6.0
165
83/46
6--22
6--22
6--22
6--22
6--23
7--23
7--22
18.00
16.00
18.00
16.00
95
230
70
120
100
90
60
0 0 0
87
80
30
120
2.0
10
5
3
5
165
6.0
0
0.3
75
75
30
1.0
30
100
100
0
2.0
30
90
80
76
75
5
20
5
55
16
120
50
0
- 2
- 3
-
●▐
+
(50)
V22/V40 Mon 12:34
Boiler °C
O2 %
Fluegas °C
Tank °C
Status Stop
Menu
Time setting
Weekday Mon
Time 12:34
Menu
Room temp °C 21.6 (21.5)
Operation data
Stored operation data
Night reduction
Installer
Reset Alarm/msg
Room temperature
Fine adjustment
Room temperature
Room temp °C 20.0 (20.2)
Displayed if room sensor is defi ned.
Settings
Language English
Settings boiler
Setting tank charg.
Settings DHW
Settings add heat
Settings heatcirc.
Save settings
Load settings
Load V22/V40 Lamb
Load V40
Alarm info
Latest alarm:
-
Sum alarm:
Boiler sensor 0
Upper sensor 0
Lower sensor 0
DHW sensor 0
Flue gas sensor 0
Fan Fuse 0
Lambda probe 0
Prim fl ow 1 0
Room sensor 1 0
Prim fl ow 2 0
Room sensor 2 0
Outdoor sensor 0
Com error 1 0
Com error 2 0
Room temperature
Room temperature 1
Room temperature 2
Operation data
Status Stop
Boiler °C
Fluegas °C
Fan %
O2 fl ue gas %
Damper primary %
Damper secondary %
Outdoor °C - 5
Room temp 1 20.1 (20.3)
Primary fl ow 1 °C 47 (47)
Heat circ. pump 1 On
Mixing valve 1 Opens
Room temp 2 21.6 (22.0)
Primary fl ow 2 °C 48 (51)
Heat circ. pump 2 On
Mixing valve 2 Opens
Charging pump Off
Tank °C 80/75
DHW °C 60
DHW pump Off
Addheat Off
Program ID XXXX
Program ver 09 XXXX
Stored operation data
Operation time h 0
Reduced h 0
High BT tot 0
Max Flue 0
Opendoor 0
Opendoor h 0
N:o starts 0
Failed lgn 0
Reset Alarm/msg
- No Alarms - / - Ok for reset -
Service 200h
Start up failed
High Boiler temp
High Flue gas temp
Night reduction
Heating circuit 1
Heating circuit 2
Installer
Settings
Service
Alarm info
Night red rad sys
Active Yes
Type Block
Room temp decreasing °C -2
Primary fl ow decreasing -3
Week prog
Block
Block
Decrease Sun
Increase Wed
Decrease Thu
Increase Fri
Week prog.
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Service
Function test
Settings coded
Settings boiler
Boiler max °C
Max fl ue gas °C
Heating phase PT °C
Shutdown phase FG °C
Stop FG °C
Boiler min stop FG °C
Start time
Tank min temp Off
Type Wood
Setting tank charge
Type Charge group
Start charge group FG °C
Start charge pump BT °C
Stop charge pump BT °C
Settings DHW
DHW pump Off
DHW temp °C
DHW diff °C
Settings Addheat
Addheat Off
Addheat temp °C
Addheat diff °C
Settings Heat circ.
Heat circ. 1
Heat circ. 2
Settings
Save settings
Confi rm with OK
Settings
Load settings
Confi rm with OK
Settings
Load settings V40
Confi rm with OK
Inställningar
Load settings V22/V40 Lambda
Confi rm with OK
Heating circuit
Heat circ On
Room sensor Off
Max primary fl ow °C
Min primary fl ow °C Off
Heating off, outdoor °C
Heating off, time
Inclination °C
Adjustment °C
Room temp decrease
Primary fl ow decrease
Function test
Flue gas fan % 0
Charging pump Off
Addheat Off
DHW pump Off
Alarm output Off
Damper primary % 0
Damper secondary % 0
Heat circ. pump 1 Off
Mixing valve 1 -
Heat circ. pump 2 Off
Mixing valve 2 -
Setting coded
Code
Alarm reset No
Fan startup
Fan max
Fan min
Fan reg. time s
Fan reg. K
Reduced diff FG °C
Reduced diff B °C
Heat phase Re °C
Start phase time m
Set value fl ue gas °C
Lambda control Yes
Value O2 %
Calibration O2 %
Accuracy O2 %0
Prim. start up %
Prim. air max %
Prim. air min %
Prim. reg. K
Prim. reg. time s
Sec. startup %
Sec. max high %
Sec.min low %
Sec. reg. K
Sec. reg. time s
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

CTC Union V22 Installation and Maintenance Manual

Type
Installation and Maintenance Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI