11
For the property owner
CTC EcoZenith I 550
The CTC EcoZenith I 550 Construction
The illustration shows the construction of the product.
Control System
The CTC EcoZenith I 550 is
equipped with an intelligent
control system which controls and
monitors all parts of the heating
system. The CTC EcoZenith I 550
ensures that the most economical
way of heating the house and
the hot water is prioritized.
Finned Coil for Hot Water
The CTC EcoZenith I 550 is
equipped with a well dimensioned
nned copper coil and does
not contain any heater which
can rust. The temperature can
be kept low without the risk
of Legionella bacteria.
Immersion heaters in
Upper Part of Tank
Built-in upper Immersion heater.
When connected to a heat pump,
the immersion heater acts as
additional heat.
(The upper immersion heater
is optional)
Lower Tank
In the lower part of the tank,
hot water is preheated in
the coil by the solar- or heat
pump-heated water.
Solar Coil Connections
The well dimensioned, 10 m long,
nned coil can be connected
directly to the solar panels.
Lower immersion heater
Built-in lower immersion heater.
Upper Tank Connections
The upper part of the tank, the
additional part, can be heated by
heat pump and connected to heat
sources such as electric, gas,
oil and pellet boilers. Heat from
a wood boiler is delivered to
this part. Connections are placed
symmetrically on both sides of
the tank.
Insulation
The tank is insulated by 90-mm-thick
molded polyurethane foam for minimum
heat loss.
Lower Tank Connections
The heat pump and solar system
are connected to the lower tank.
Water to be heated by wood
boiler is taken from here, and
heat which is to be stored in a
buffer tank is also taken from this
part. Connections are available
symmetrically on both sides of
the tank.
Insulated tank divider
Between the tank’s upper and
lower tank is an insulated tank
divider. This provides high
temperatures in the upper tank
for good hot water capacity and
low temperatures in the lower
tank for best operating economy.
Heat Distribution Pipes
The heat distribution pipes ensure
that heat from the solar coil is
directed to the upper tank and
that the cold, after a hot water
tapping, is directed to the lower
part of the tank to be heated
again by sun or heat pump.
Upper Tank
In the upper part of the tank, the
warm water in the coil is heated
up to the desired temperature.
Bivalent Mixing Valve
The automatic mixing valve
constantly supervises that even
heat is delivered to the radiator
system. The valve has double
ports and takes the warm radiator
water from the solar- and heat-
pump-heated water in the lower
part of the tank rst.
Fresh Water Connections
The building’s fresh water supply
is connected here. The cold water
is fed down to the lower part of
the coiling, where it is preheated.
Top Connection
For connection of expansion
vessel and/or safety valve.