CGU-2K-24

Wolf CGU-2K-24, CGG-2-18, CGG-2-24, CGG-2K-18, CGG-2K-24, CGU-2-18, CGU-2-24, CGU-2K-18 Operating Instructions Manual

  • Hello! I am an AI chatbot trained to assist you with the Wolf CGU-2K-24 Operating Instructions Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Wolf GmbH · Postfach 1380 · 84048 Mainburg · Tel. 08751/74-0 · Fax 08751/741600 · Internet: www.wolf-heiztechnik.de
Operating instructions
as combi boilers and gas boilers
with integrated cylinder connection
CGU-2-18/24
CGG-2-18/24
CGU-2K-18/24
CGG-2K-18/24
Part no: 3062348_0511 Subjecttomodications GB
2 3062348_0511
Index
Index ...................................................................................................... Page
General information .................................................................................................... 2
Safetyinstructions ...................................................................................................... 3
Installationinformation/Maintenanceinformation .................................................. 4-5
Hydraulicconnections ............................................................................................... 6
Control unit operation ................................................................................................. 7
Informationforenergy-efcientoperation ............................................................... 8-9
Faults/Faultcodes .................................................................................................... 9
Type plate (Example)
Thetypeplateislocatedontheinsideoftheboilercasingandcontainsthefollowing
information:
Theseoperatinginstructionsarefortheattentionofthesystemuser.Theinstallation
andmaintenanceinstructionsaredocumentsintendedforthecontractor.
Enclosed documents
Gasisanenvironmentally-friendlyfuelwhichdoesnotrepresentanydangerunless
handledwithgrossnegligence.Yourgasredboilerisahigh-qualityproduct which
incorporatesthelatestsafetytechnology.
These safety instructions should protect you from potential risks.
General notes
3062348_0511 3
Safety instrucions
If you smell gas
- Neverturnonalightswitch.
- Neveroperateelectricalswitches.
-Keepnakedamesaway.
- Closethegasshut-offvalve.
- Openwindowsanddoors.
- Informyourgassupplyutility;useatelephoneoutsidethedangerarea.
Caution - risk of poisoning, suffocation and explosion.!
If you smell ue gas
- Shutthesystemdown.
- Openwindowsanddoors.
- Notify your local contractor.
Caution - risk of poisoning.
When changing a fuse
- Isolatetheboilerfromthemainssupplypriortochangingafuse.Themainsterminals
oftheboilerare‘live’evenwhentheON/OFFswitchhasbeenswitchedOFF.
Caution - risk of electrocution.
Frost protection
AslongastheboilerisswitchedON,itwillbeautomaticallyprotectedagainstfrost.
Theuseofanti-freezeisnotpermissible.
Completelydraintheboilerifnecessary.
Caution - risk of water damage and faulty function through freezing.
Balanced ue system
(only CGG-2)
With low outside temperatures, the water vapour contained in the ue gas may
condenseandfreezeonthebalancedue.This ice may fall from the roof causing
injury or material losses. Preventicefromfallingbytakingon-sitemeasures,e.g.the
installationofasnowcatchergrille.
Caution - risk of injury.
SAFETY INSTRUCTIONS
4 3062348_0511
Installation information /
Maintenance information
Donotuse(forcleaning,polishing,etc.)orstoresprays,solvents,chlorinatedcleaning
agents,paints,lacquer,adhesives,salts,etc.onorinthevicinityofthegasredboiler.
Underunfavourableconditions,thesematerialsmayleadtocorrosionintheboilerand
theuegassystem.Ductedventsroutedthrougharoofmayalsocontaincorrosive
vapours.
Caution - ignoring this rule may lead to a risk of re as well as a risk of
destruction, poisoning or explosion.
Corrosion protection
- Yourgasredboilershouldonlybeinstalledandmodiedbyanapprovedheating
contractor,asonlytheyhavetheessentialknowledgetocarryoutsuchwork.
- Gascomponentsmustnotbemodied.
- Never close or restrict the ventilation apertures in doors or walls when
operating the boiler in the open ue mode; only start the boiler when the ue
has been fully installed.
- Only operate the boiler in balanced ue mode, after the balanced ue system
has been fully installed and the wind protector is not covered up.
- Thegasredboilermayonlybeinstalledinroomsthatareprotectedfromfrost.
- Neverisolatetheboilerfromthepowersupplywhenoutsidetemperaturesfallbelow
freezing,asotherwisethereisariskofthesystemfreezing-up.
- Donotmodifythedrainorthesafetyvalve.
Caution - ignoring this rule may lead to a risk of re, as well as a risk
of destruction, poisoning or explosion.
Do not use or store explosive and ammable materials, e.g. petrol,
thinners, paints, paper, etc. inside the boiler room.
Positioning / modications
Energy, and therefore operating costs, can be effectively saved through low DHW
temperatures.Furthermore,scalingupoftheat-plateheatexchangerinthegascombi
boilerversion can beprevented. If the water’s hardness is greater than 15°d.H. the
cylinderwatertemperatureshouldbelimitedto55°C.
Water hardness
3062348_0511 5
Installation information /
Maintenance information
Cleanthecasingwithadampclothandamildcleaningagent(whichmustnotcontain
chlorine).Thendryimmediatelyafterwards.Thegasredboilercomponentsmayonly
be cleaned by a heating contractor.
Care
Caution - only the heating contractor has the required knowledge and
expertise!
- Accordingtotheregionalregulations,theuserisobligedtoarrangeregularmainte-
nanceofthesystem,inordertoensurethereliableandsafefunctionofthegasred
boiler.
- Yourboilershouldbeservicedannually.
- Maintenanceisexplicitlydetailedintheinstallationandmaintenanceinstructions.
- Isolatetheboilerpowersupplybeforeanymaintenanceworkiscarriedout.
- Aftercompletingmaintenance,andbeforethegasredboilerisrestarted,ensure
thatallcomponentsthathavebeenremovedformaintenancehavebeenproperly
retted.
- Werecommendyouarrangeamaintenancecontractwithanapprovedheatingcon-
tractor.
Please keep your operating instructions safe, in an easily accessible place
near your gas red boiler.
Maintenance
6 3062348_0511
Hydraulic connections
Please note before commissioning
The heating system must be completely lled with water. If necessary top up with
water.Whenllingtheheatingsystem,theshut-offvalvesmustbeopen.Thesystem
pressuremustbe1.5to2.5bar.Theconnectionbetweenthetapwaterandheating
waterrequiredforllingmustberemovedafterthellhasbeencompleted.Otherwise
thereisariskthatyourtapwaterwillbecontaminatedbyheatingwater.
The system may overheat if the boiler is operated without water.
Inhibitors are not permissible. Otherwise there is a risk of damage to
the boiler.
Filling the system
Note
Theshut-offvalvesforheatingowandheatingreturnmustbeopen.
Opening the shut-off
equipment
Regularly check the system pressure. The pressure gauge must indicate between
1.5and2.5bar.Your heatingcontractorwillexplainhowto top upyoursystem.Do
not supplement your heating water with additives, otherwise components may be
damaged.
Checking the heating
water
Shut-off valves
(accessory)
Fill and drain connection
Heating return
(incl.llanddrain
connection)
Heating ow
(incl.llanddrain
connection)
Gas ball valve
Open:Pushandturnanti-clockwise
Close:Turnclockwise
Maintenance valve
Heating return
Close
Open
Maintenance valve
Heatingow
Close
Open
3062348_0511 7
Control unit operation
Control unit operation
ON/OFFswitch
DHW temperature
selector
Heatingwater
temperature
selector
Resetbutton Thermometer
Pressure
gauge
Illuminated
signalring
Illuminated signal ring as status
indicator
Illuminated signal ring Explanation
Flashinggreen
Standby(powersupplyON,burnerOFF,
e.g.summermode)
Constantgreenlight Wintermode:Pumprunning,burnerOFF
Flashingyellow Emissionstestmode
Constantyellowlight Burneroperates,ameON
Flashingred Fault
Summermode(heatingOFF)
Wintermodeposition2to8
Emissionstestmode
(illuminatedringashesyellow)
DHW temperature selector,
boiler *
1(15°C)...9(65°C)Gasboilerwithcylinder
1(40°C)...9(65°C)Gascombiboiler
Heating water temperature
selector
2(40°C)...8(80°C)
* When the hardness of the water is over 15°d.H. (2.5mol/m³) the cylinder water
temperaturemaybesettoamaximumof55°C.Thiscorrespondswithoutaccessory
controllertoasettingof5-6ontheDHWtemperatureselectorwithgascombiboilers
or6-7ongasboilerswithcylinders.
The BM programming module can also be integrated into the control unit of gas
redboilers.Thatmeansthatalladjustmentsaremadeatthecontrolunitofthegas
red boiler. For installation and operation, see BM programming module operating
instructions.
Note:
8 3062348_0511
Information for energy-efcient
operation
Saving energy with modern heating technology: A Wolf boiler saves you hard
cash.
Withmoderncondensingtechnologyenergyisusedefcientlyforheating.
Use as little electrical energy as possible.
Operatethesystemwiththeheatingpumpatthelowestpossiblelevel.
Regular heating system maintenance pays for itself.
Acontaminatedburnerorpoorlyadjustedgasboilercanreducetheheatingsystem
efciency.Regularheatingsystemmaintenancethroughyourlocalcontractorquickly
paysforitself.
Heating at the lowest energy level
Operateyourheatingsystem,wherepossible,withareturntemperatureoflessthan
45°C,toachievethehighestpossibleenergyutilisation.
A heating system control unit also regulates your heating costs
A heating systemin standby modesaves energy.A modern, weather-compensated
orroomtemperaturedependentheatingsystemcontrolunitensures-withautomatic
nightsetbackand thermostaticvalves-thatthesystem onlyoperateswhenheatis
required,savingmoneyfortherestofthetime.
- Equipyourheatingsystemwithaweather-compensatedheatingcontrollerfromthe
Wolfrangeofaccessories.Yourheatingcontractorwillbehappytoadviseyouabout
optimumadjustments.
- InconjunctionwiththeWolfcontrolaccessories,usethenightsetbackfunctionto
matchtheenergyleveltotheactualdemandperiod.
- Usetheoptionalsummermodeadjustment.
Never overheat your home
Adjust the room temperature as accurately as possible. This leaves occupants
comfortable,andenergyisnotwastedonprovidingaheatingoutputthatisnotrequired
byanyone.Differentiatebetweentheoptimumtemperaturefordifferentrooms,such
aslivingroomsandbedrooms.
A room temperature which is one degree higher than necessary represents an
additionalenergyconsumptionofapprox.6%.
- Use room thermostats to match the room temperature to the actual use of the
room.
- In the room, where you have installed a room temperature sensor, open the
thermostaticvalvefully.Thisenablesyoutoachieveoptimumcontrolcharacteristics
foryourheatingsystem.
Ensure adequate air circulation
Air must be able to freely circulate near the radiators and the room temperature
sensors,otherwisetheheatingsystemwillloseeffectiveness.Badlypositionedlong
curtainsorfurniture“swallow”upto20%ofenergy.
Heating mode
3062348_0511 9
Information for energy-efcient
operation
Keep the heat inside the room - at night too
Atnight,closingshuttersanddrawing curtains noticeably reduces heat loss viathe
windowareas.Insulatingtheradiatorrecessesandlightcolouredpaintworkcanreduce
yourheatingbillsbyupto4%.Airtightjointsatwindowsanddoorsalsohelptokeep
energyinsidetheroom.
Minimise energy loss through sensible ventilation
Ventilatingforhourslosesheatstoredinwallsandobjects.Asaresult,theambient
climatewillonlybecomecomfortableagainafterprolongedheating.Shortandthorough
airingismoreeffectiveandpleasant.
Venting the radiators
Regularly vent the radiators in every room.This safeguards the perfect function of
radiatorsandthermostats,particularlyintheupperapartmentsofapartmentblocks.
Theradiatorwillthenbeabletorespondquicklytochangingheatdemands.
Intelligent use of DHW circulation pumps
AlwayscontrolDHWcirculationpumpsviatimeswitches.Programtheseinaccordance
withyourDHWdemandpatterns.
The optimum DHW temperature
OnlyeversettheDHWtemperature,orthatofthe cylinder,tothetemperatureyou
reallyrequire.Anyadditionalheatingusesadditionalenergy.
Whenthehardnessofthewaterisover15°d.H.(2.5mol/m³)theDHWtemperature
maybesettoamaximumof55°C.Thiscorrespondswithoutaccessorycontrollertoa
settingof5-6ontheDHWtemperatureselectorwithgascombiboilers,or6-7ongas
boilerswithcylinders.Theactualtemperaturethenfallsbetween50°Cand55°C.
Sensible handling of DHW
Showering consumes only approx. 1/3 of the water volume required for a bath.
Immediatelyrepairanydrippingtaps.
DHW mode
Iftheilluminatedringofthestatusindicatorashesred,wherepossiblereadthefault
codeoftheconnectedcontrollerandnotethecode.The boiler can be restarted by
pressingtheresetbutton.Incaseofrepeatedfaults,switchOFFtheboilerandnotify
your heating contractor.
GasboilersfromtheCGU-2seriesareequippedwithanelectronicuegasmonitor.
Ifuegasisescapingatthedraughthoodthisshutsdownthegasboiler.Theboiler
restartsautomaticallyafterapprox.15mins.
Caution - risk of damage, poisoning and suffocation.
Faults / Fault codes
10 3062348_0511
Notes
3062348_0511 11
Notes
/