MR-J5

Mitsubishi Electric MR-J5 User manual

  • Hello! I am an AI chatbot trained to assist you with the Mitsubishi Electric MR-J5 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
MR-J5
User's Manual
(Hardware)
-MR-J5-_G_
-MR-J5W_-_G_
-MR-J5-_A_
Mitsubishi Electric AC Servo System
1
SAFETY INSTRUCTIONS
Please read the instructions carefully before using the equipment.
To use the equipment correctly, do not attempt to install, operate, maintain, or inspect the equipment until you have read
through this manual, installation guide, and appended documents carefully. Do not use the equipment until you have a full
knowledge of the equipment, safety information and instructions.
In this manual, the safety instruction levels are classified into "WARNING" and "CAUTION".
Note that the CAUTION level may lead to a serious consequence depending on conditions.
Please follow the instructions of both levels because they are important to personnel safety.
Forbidden actions and required actions are indicated by the following diagrammatic symbols.
In this manual, precautions for hazards that can lead to property damage, instructions for other functions, and other
information are shown separately in the "POINT" area.
After reading this manual, keep it accessible to the operator.
WARNING
Indicates that incorrect handling may cause hazardous conditions, resulting in
death or severe injury.
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in
medium or slight injury.
Indicates a forbidden action. For example, "No Fire" is indicated by .
Indicates a required action. For example, grounding is indicated by .
2
[Installation/wiring]
[Setting/adjustment]
[Operation]
[Maintenance]
WARNING
To prevent an electric shock, turn off the power and wait for 15 minutes or more before starting wiring
and/or inspection.
To prevent an electric shock, ground the servo amplifier.
To prevent an electric shock, any person who is involved in wiring should be fully competent to do the
work.
To prevent an electric shock, mount the servo amplifier before wiring.
To prevent an electric shock, connect the protective earth (PE) terminal of the servo amplifier to the
protective earth (PE) of the cabinet, then connect the grounding lead wire to the ground.
To prevent an electric shock, do not touch the conductive parts.
WARNING
To prevent an electric shock, do not operate the switches with wet hands.
WARNING
To prevent an electric shock, do not operate the switches with wet hands.
WARNING
To prevent an electric shock, any person who is involved in inspection should be fully competent to do
the work.
To prevent an electric shock, do not operate the switches with wet hands.
3
ABOUT THE MANUAL
e-Manuals are Mitsubishi Electric FA electronic book manuals that can be browsed with a dedicated tool.
e-Manuals enable the following:
Searching for desired information in multiple manuals at the same time (manual cross searching)
Jumping from a link in a manual to another manual for reference
Browsing for hardware specifications by scrolling over the components shown in product illustrations
Bookmarking frequently referenced information
Copying sample programs to engineering tools
If using the servo for the first time, prepare and use the following related manuals to ensure that the servo is used safely. The
manuals used differ depending on the interface of the servo amplifier. For details, refer to the User's Manual (Introduction).
This manual covers the following servo amplifiers.
MR-J5-_G_/MR-J5W_-_G_/MR-J5-_A_
In this manual, the servo amplifier names are abbreviated as shown below.
Symbol Servo amplifier
[G] MR-J5-_G_/MR-J5W_-_G_
[A] MR-J5-_A_
Rotary Servo Motor
Linear Servo Motor
Direct Drive Motor
This manual is necessary primarily for installing, wiring, and
using options.
The manual is necessary for operation of servo amplifiers.
The manual is necessary for adjustment of operation status.
The manual is necessary for using communication functions.
The manual is necessary for specifying the causes of alarms
and warnings.
Partner Encoder
Function
Adjustment
Object Dictionary
Troubleshooting
Introduction
Hardware
Communication Function
Parameters It describes the parameters of the servo amplifier.
It describes the objects for the servo amplifier.
For the usage of each function, refer to this manual.
4
U.S. CUSTOMARY UNITS
U.S. customary units are not shown in this manual. Convert the values if necessary according to the following table.
Quantity SI (metric) unit U.S. customary unit
Mass 1 [kg] 2.2046 [lb]
Length 1 [mm] 0.03937 [inch]
Torque 1 [N•m] 141.6 [oz•inch]
Moment of inertia 1 [(× 10
-4
kg•m
2
)] 5.4675 [oz•inch
2
]
Load (thrust load/axial load) 1 [N] 0.2248 [lbf]
Temperature N [°C] × 9/5 + 32 N [°F]
5
CONTENTS
CONTENTS
SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
ABOUT THE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
U.S. CUSTOMARY UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
CHAPTER 1 INTRODUCTION 12
1.1 Wiring procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.2 Servo amplifier/motor combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Rotary servo motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Linear servo motor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Direct drive motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.3 Wiring check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Power supply system wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
I/O signal wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.4 Surrounding environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
CHAPTER 2 INSTALLATION 27
2.1 Mounting direction and clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.2 Keeping out foreign materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.3 Cable stress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2.4 Fan unit replacement procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
List of applicable fan units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Fan unit removal procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Fan unit installation procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
2.5 Restrictions when using this product at an altitude exceeding 1000 m and up to 2000 m . . . . . . . . . . . . 33
CHAPTER 3 SIGNALS AND WIRING 34
3.1 Example power circuit connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
200 V class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
400 V class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Using servo amplifier with DC power supply input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.2 Example I/O signal connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
MR-J5-_G_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
MR-J5W_-_G_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
MR-J5-_A_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
3.3 Explanation of power supply system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Explanation of signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Power-on procedure [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Power-on procedure [A]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Wiring CNP1, CNP2, and CNP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
3.4 Connectors and pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Connectors and pin assignments [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Connectors and pin assignments [A]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
3.5 Signal (device) explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Input device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Output device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
6
Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
3.6 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Internal connection diagram [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Internal connection diagram [A]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Detailed explanation of interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Source I/O interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
3.7 Servo motor with an electromagnetic brake. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
3.8 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
CHAPTER 4 DIMENSIONS 104
4.1 MR-J5-_G_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
200 V class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
400 V class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
4.2 MR-J5W_-_G_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
4.3 MR-J5-_A_ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
200 V class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
400 V class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
4.4 Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
CN3 connector (1-axis servo amplifier) [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
CN3 connector (multi-axis servo amplifier) [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
CN3 connector [A] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
SCR connector system (3M) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
CHAPTER 5 CHARACTERISTICS 118
5.1 Overload protection characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
5.2 Power supply capacity and generated loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Power supply capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Generated loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Using servo amplifier with DC power supply input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
5.3 Dynamic brake characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Dynamic brake operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
5.4 Cable flex life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
5.5 Inrush currents at power-on of main circuit and control circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
CHAPTER 6 OPTIONS AND PERIPHERAL EQUIPMENT 172
6.1 Cable/connector sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
Combinations of cable/connector sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
MR-D05UDL3M-B STO cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
Ethernet cable [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
6.2 Regenerative option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Combination and regenerative power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Selection of the regenerative option (1-axis servo amplifier). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Selection of the regenerative option (multi-axis servo amplifier) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Servo parameter setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Connection of regenerative option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Mounting direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
6.3 MR-CM simple converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Combination of simple converter and servo amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
7
CONTENTS
Servo amplifier setting when using a simple converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
Simple converter standard specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
External interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Signals and wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Peripheral equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
Mounting direction and clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
6.4 Multifunction regeneration converter (FR-XC-(H)) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Servo amplifier settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Capacity selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Wiring and peripheral options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
6.5 PS7DW-20V14B-F junction terminal block (recommended) (1-axis servo amplifier) [G] . . . . . . . . . . . . . 213
6.6 MR-TB26A junction terminal block (multi-axis servo amplifier) [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
6.7 MR-TB50 junction terminal block [A]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
6.8 MR Configurator2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Engineering tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Precautions for using USB communication function and Ethernet communication function . . . . . . . . . . . . . . . 219
6.9 Selection example of wires. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
6.10 Molded-case circuit breakers, fuses, magnetic contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Main circuit wiring (connecting multiple servo amplifiers to one molded-case circuit breaker) . . . . . . . . . . . . . 229
Example settings that comply with IEC/EN/UL 61800-5-1 and CSA C22.2 No.274 . . . . . . . . . . . . . . . . . . . . . 232
6.11 Power factor improving DC reactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
6.12 Power factor improving AC reactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
6.13 Relay (recommended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
6.14 Noise reduction techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
6.15 Earth-leakage current breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Selection method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Selection example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
6.16 EMC filter (recommended) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
6.17 MR-J3-D05 safety logic unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Contents of the package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Terms related to safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Residual risks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Block diagram and timing chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Maintenance and disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Functions and configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Signal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
LED display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Rotary switch settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Combinations of cables and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
6.18 J5-CHP07-10P cabinet-mounting attachment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Compatible models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
View when installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Fitting method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
8
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
Installation dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
6.19 J5-CHP08 grounding terminal attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Compatible models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Appearance and dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
View when installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
Installation dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
CHAPTER 7 ABSOLUTE POSITION DETECTION SYSTEM 294
7.1 Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Restrictions [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Restrictions [A] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
System architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Servo parameter setting [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Servo parameter setting [A]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Homing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Checking the detected absolute position data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Procedure of replacing a servo motor with battery-less absolute position encoder . . . . . . . . . . . . . . . . . . . . . 296
7.2 Battery-less/battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
Connecting the battery-less encoder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
Connecting the battery backup type absolute position encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
7.3 Absolute position detection system by DIO [A] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Standard connection example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Signal explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
Startup procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
Absolute position data transfer protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303
Absolute position data transfer errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
7.4 Absolute position detection system via communication [A] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318
Serial communication command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318
Absolute position data transfer protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
CHAPTER 8 USING STO FUNCTION 323
8.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Terms related to safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Residual risks of the STO function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
8.2 Functional safety I/O signal connector (CN8) and pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
Pin assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
Signal (device) explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
How to pull out the STO cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327
8.3 Connection example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
Precautions for compliance with stop category 1 (IEC/EN 60204-1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .328
Precautions for compliance with stop category 0 (IEC/EN 60204-1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .328
9
CONTENTS
Connection example for CN8 connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329
External I/O signal connection example using the MR-J3-D05 safety logic unit . . . . . . . . . . . . . . . . . . . . . . . . 329
External I/O signal connection example using an external safety relay unit . . . . . . . . . . . . . . . . . . . . . . . . . . .332
8.4 Detailed explanation of interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Sink I/O interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333
Source I/O interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
CHAPTER 9 USING FUNCTIONAL SAFETY [G] 336
9.1 Function block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
Safety sub-function control by input device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
Safety sub-function control by network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
9.2 System architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
Safety sub-function control by input device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
Safety sub-function control by network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339
9.3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
9.4 Connectors and pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
9.5 Example I/O signal connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
Input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341
9.6 Connecting I/O interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
Source input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
Sink input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
9.7 Wiring the SBC output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
9.8 Noise reduction techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
9.9 Example of connection with other devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
Safety sub-function control by input device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
Safety sub-function control by network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346
CHAPTER 10 USING A LINEAR SERVO MOTOR 347
10.1 Functions and configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Configuration including peripheral equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
10.2 Startup [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
Startup procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
Magnetic pole detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
How to replace servo amplifier without magnetic pole detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
10.3 Startup [A] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
Startup procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Magnetic pole detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
How to replace servo amplifier without magnetic pole detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372
10.4 Basic functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Homing [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Homing [A]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 379
Linear servo control error detection function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385
About MR Configurator2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
10.5 Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
Auto tuning function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
Machine analyzer function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389
10
10.6 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
Overload protection characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
Power supply capacity and generated loss (1-axis servo amplifier) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393
Power supply capacity and generated loss (multi-axis servo amplifier) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .394
Dynamic brake characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
Permissible load to motor mass ratio when the dynamic brake is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .397
10.7 Absolute position detection system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398
CHAPTER 11 USING A DIRECT DRIVE MOTOR 399
11.1 Functions and configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
Configuration including peripheral equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
11.2 Startup [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
Startup procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401
Magnetic pole detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
11.3 Startup [A] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
Startup procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
Magnetic pole detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
11.4 Basic functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
Operation from controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
Servo control error detection function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421
11.5 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424
Overload protection characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424
Power supply capacity and generated loss (1-axis servo amplifier) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427
Power supply capacity and generated loss (multi-axis servo amplifier) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .428
Dynamic brake characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430
Permissible load to motor inertia ratio when the dynamic brake is used. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .432
11.6 Absolute position detection system [G] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432
11.7 Absolute position detection system [A] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432
11.8 Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
Selection of battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
MR-BAT6V1SET battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
MR-BAT6V1SET-A battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438
MR-BT6VCASE battery case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 441
MR-BAT6V1 battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 447
Battery cable and junction battery cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
CHAPTER 12 USING A FULLY CLOSED LOOP SYSTEM 449
12.1 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 449
12.2 Functions and configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
Function block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451
Operation mode and load-side encoder combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453
System architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
12.3 Signals and wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 456
Encoder cable configuration diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 456
12.4 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
Servo parameter setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
Checking position data of the load-side encoder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464
12.5 Basic functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465
11
CONTENTS
Homing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465
Operation from controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468
Fully closed loop control error detection function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 468
About MR Configurator2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470
12.6 Options and peripheral equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
MR-J4FCCBL03M branch cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472
12.7 Absolute position detection system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473
REVISIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .474
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .475
TRADEMARKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .476
12
1 INTRODUCTION
1.1 Wiring procedure
1 INTRODUCTION
1.1 Wiring procedure
Procedure Description Reference
1. Installation
Install a servo amplifier. Page 27 INSTALLATION
2. Connecting the power circuit
Connect the power circuit. Page 35 Example power
circuit connections
3. Connecting I/O signals
Connect I/O signals. Page 43 Example I/O
signal connections
4. Connecting to the servo
motor
Connect the servo amplifier to a servo motor.
If using a linear servo motor, connect the servo amplifier to a linear encoder.
If using the servo amplifier in a fully closed loop system, connect the servo
amplifier to a linear encoder or a rotary encoder.
Rotary Servo Motor
User's Manual (HK series)
Page 347 USING A
LINEAR SERVO MOTOR
Page 399 USING A
DIRECT DRIVE MOTOR
Page 449 USING A
FULLY CLOSED LOOP
SYSTEM
5. Connecting options
Connect options. Page 172 OPTIONS
AND PERIPHERAL
EQUIPMENT
6. Other precautions
If using the absolute position detection system and the STO function, perform
wiring and settings as necessary.
Page 294 ABSOLUTE
POSITION DETECTION
SYSTEM
Page 323 USING STO
FUNCTION
Page 336 USING
FUNCTIONAL SAFETY [G]
7. Wiring check
Check that the servo amplifier and the servo motor are wired correctly by
visually inspecting them or by using a method such as the DO forced output
function.
Page 23 Wiring check
8. Checking the surrounding
environment
Check the environment surrounding the servo amplifier and servo motor. Page 26 Surrounding
environment
1 INTRODUCTION
1.2 Servo amplifier/motor combinations
13
1
1.2 Servo amplifier/motor combinations
By combining a servo motor with a larger capacity servo amplifier, the maximum torque can be increased to 400 % or 450 %.
Rotary servo motor
HK-KT series
The combinations of geared servo motors and servo amplifiers are the same as those listed in the following tables. However,
for geared servo motors, the maximum torque does not increase even when they are combined with a servo amplifier whose
combination allows for increased torque as specified in the following tables.
200 V class servo amplifier
1-axis servo amplifier
: Standard torque : Increased torque
Rotary servo motor Servo amplifier MR-J5-_
10_ 20_ 40_ 60_ 70_ 100_ 200_ 350_
HK-KT_W 40 HK-KT053W 
HK-KT13W 
HK-KT1M3W 
60 HK-KT13UW 
HK-KT23W 
HK-KT43W 
HK-KT63W 
80 HK-KT23UW 
HK-KT43UW 
HK-KT7M3W 
HK-KT103W 
90 HK-KT7M3UW 
HK-KT103UW 
HK-KT153W 
HK-KT203W 
HK-KT202W 
HK-KT_4_W 60 HK-KT434W 
HK-KT634W 
80 HK-KT7M34W 
HK-KT1034W 
90 HK-KT1534W 
HK-KT2034W 
HK-KT2024W 
14
1 INTRODUCTION
1.2 Servo amplifier/motor combinations
Multi-axis servo amplifier
As long as the servo motor is compatible with the servo amplifier, any combination of the following is possible:
servo motor series, capacity, rotary servo motor, linear servo motor, and direct drive motor.
: Standard torque : Increased torque
400 V class servo amplifier
Use servo motors manufactured after September 2020. Otherwise, [AL. 01A Servo motor combination error] occurs.
1-axis servo amplifier
: Standard torque : Increased torque
Rotary servo motor Servo amplifier MR-J5W2-_ Servo amplifier MR-J5W3-_
22G 44G 77G 1010G 222G 444G
HK-KT_W 40 HK-KT053W 
HK-KT13W 
HK-KT1M3W 
60 HK-KT13UW 
HK-KT23W 
HK-KT43W 
HK-KT63W 
80 HK-KT23UW 
HK-KT43UW 
HK-KT7M3W 
HK-KT103W 
90 HK-KT7M3UW 
HK-KT103UW 
HK-KT_4_W 60 HK-KT434W 
HK-KT634W 
80 HK-KT7M34W 
HK-KT1034W 
90 HK-KT1534W 
HK-KT2034W 
HK-KT2024W 
Rotary servo motor Servo amplifier MR-J5-_
60_4_ 100_4_ 200_4_ 350_4_
HK-KT_W 40 HK-KT053W 
HK-KT13W 
HK-KT1M3W 
HK-KT_4_W 60 HK-KT434W
HK-KT634W 
80 HK-KT7M34W 
HK-KT1034W 
90 HK-KT1534W 
HK-KT2034W 
HK-KT2024W 
1 INTRODUCTION
1.2 Servo amplifier/motor combinations
15
1
HK-ST series
The combinations of geared servo motors and servo amplifiers are the same as those listed in the following tables. However,
for geared servo motors, the maximum torque does not increase even when they are combined with a servo amplifier whose
combination allows for increased torque as specified in the following tables.
200 V class servo amplifier
1-axis servo amplifier
: Standard torque : Increased torque
*1 The combinations with servo amplifiers for the HK-ST152_G_ are the same as those for the HK-ST172W.
*2 Use servo motors manufactured after December 2020. Otherwise, [AL. 01A Servo motor combination error] occurs.
Multi-axis servo amplifier
As long as the servo motor is compatible with the servo amplifier, any combination of the following is possible:
servo motor series, capacity, rotary servo motor, linear servo motor, and direct drive motor.
: Standard torque : Increased torque
Rotary servo motor Servo amplifier MR-J5-_
40_ 60_ 70_ 100_ 200_ 350_ 500_ 700_
HK-ST_W
*1
130 HK-ST52W 
HK-ST102W 
HK-ST172W 
HK-ST202AW 
HK-ST302W 
*2
176 HK-ST202W 
HK-ST352W 
*2
HK-ST502W 
HK-ST702W 
HK-ST_4W 130 HK-ST524W 
HK-ST1024W 
HK-ST1724W 
HK-ST2024AW 
HK-ST3024W 
176 HK-ST2024W 
HK-ST3524W 
HK-ST5024W 
*2
HK-ST7024W 
Rotary servo motor Servo amplifier MR-J5W2-_ Servo amplifier MR-
J5W3-_
44G 77G 1010G 444G
HK-ST_W 130 HK-ST52W 
HK-ST102W 
HK-ST_4W 130 HK-ST524W 
HK-ST1024W 
HK-ST1724W 
HK-ST2024AW 
16
1 INTRODUCTION
1.2 Servo amplifier/motor combinations
400 V class servo amplifier
Use servo motors manufactured after December 2020. Otherwise, [AL. 01A Servo motor combination error] occurs.
: Standard torque : Increased torque
*1 The combinations with servo amplifiers for the HK-ST1524_G_ are the same as those for the HK-ST1724W.
HK-RT series
The HK-RT_4W will be available in the future.
200 V class servo amplifier
: Standard torque : Increased torque
*1 The HK-RT153W cannot be driven with the MR-J5-350_.
*2 The dynamic brake time constant is longer than when the HG-RR103 and MR-J4-200_ are used in combination. To obtain the dynamic
brake time constant equivalent to the combination of the HG-RR103 and MR-J4-200_, use the HK-RT103W and MR-J5-200_ in
combination. For how to calculate the coasting distance, refer to the following page.
Page 129 Dynamic brake characteristics
400 V class servo amplifier
: Standard torque : Increased torque
Rotary servo motor Servo amplifier MR-J5-_
60_4_ 100_4_ 200_4_ 350_4_
HK-ST_4W
*1
130 HK-ST524W 
HK-ST1024W 
HK-ST1724W 
HK-ST2024AW 
HK-ST3024W 
176 HK-ST2024W 
HK-ST3524W 
Rotary servo motor Servo amplifier MR-J5-_ Servo amplifier
MR-J5W2-_
100_ 200_ 350_ 500_ 700_ 1010G
HK-RT_W 90 HK-RT103W
*2

HK-RT153W
*1

HK-RT203W 
130 HK-RT353W 
HK-RT503W 
HK-RT703W 
Rotary servo motor Servo amplifier MR-J5-_
100_4_ 200_4_ 350_4_
HK-RT_4W 90 HK-RT1034W 
HK-RT1534W 
HK-RT2034W 
130 HK-RT3534W 
1 INTRODUCTION
1.2 Servo amplifier/motor combinations
17
1
Linear servo motor
Set [Pr. PA17] and [Pr. PA18.0-3] according to the linear servo motor to be used.
Linear servo motors cannot be used with 400 V class servo amplifiers.
LM-H3 series
1-axis servo amplifier
Multi-axis servo amplifier
As long as the servo motor is compatible with the servo amplifier, any combination of the following is possible:
servo motor series, capacity, rotary servo motor, linear servo motor, and direct drive motor.
Linear servo motor Servo amplifier MR-J5-_
Primary side (coil) Secondary side
(magnet)
40_ 70_ 200_ 350_
LM-H3P2A-07P-BSS0 LM-H3S20-288-BSS0
LM-H3S20-384-BSS0
LM-H3S20-480-BSS0
LM-H3S20-768-BSS0

LM-H3P3A-12P-CSS0 LM-H3S30-288-CSS0
LM-H3S30-384-CSS0
LM-H3S30-480-CSS0
LM-H3S30-768-CSS0

LM-H3P3B-24P-CSS0 
LM-H3P3C-36P-CSS0 
LM-H3P3D-48P-CSS0 
LM-H3P7A-24P-ASS0 LM-H3S70-288-ASS0
LM-H3S70-384-ASS0
LM-H3S70-480-ASS0
LM-H3S70-768-ASS0

LM-H3P7B-48P-ASS0 
LM-H3P7C-72P-ASS0 
LM-H3P7D-96P-ASS0 
Linear servo motor Servo amplifier MR-J5W2-_ Servo amplifier MR-J5W3-_
Primary side (coil) Secondary side
(magnet)
44G 77G 1010G 444G
LM-H3P2A-07P-BSS0 LM-H3S20-288-BSS0
LM-H3S20-384-BSS0
LM-H3S20-480-BSS0
LM-H3S20-768-BSS0

LM-H3P3A-12P-CSS0 LM-H3S30-288-CSS0
LM-H3S30-384-CSS0
LM-H3S30-480-CSS0
LM-H3S30-768-CSS0

LM-H3P3B-24P-CSS0 
LM-H3P3C-36P-CSS0 
LM-H3P3D-48P-CSS0 
LM-H3P7A-24P-ASS0 LM-H3S70-288-ASS0
LM-H3S70-384-ASS0
LM-H3S70-480-ASS0
LM-H3S70-768-ASS0

LM-H3P7B-48P-ASS0 
LM-H3P7C-72P-ASS0 
LM-H3P7D-96P-ASS0 
18
1 INTRODUCTION
1.2 Servo amplifier/motor combinations
LM-U2 series
1-axis servo amplifier
Multi-axis servo amplifier
As long as the servo motor is compatible with the servo amplifier, any combination of the following is possible:
servo motor series, capacity, rotary servo motor, linear servo motor, and direct drive motor.
Linear servo motor Servo amplifier MR-J5-_
Primary side (coil) Secondary side
(magnet)
20_ 40_ 60_ 70_ 200_ 350_ 500_
LM-U2PAB-05M-0SS0 LM-U2SA0-240-0SS0
LM-U2SA0-300-0SS0
LM-U2SA0-420-0SS0

LM-U2PAD-10M-0SS0 
LM-U2PAF-15M-0SS0 
LM-U2PBB-07M-1SS0 LM-U2SB0-240-1SS1
LM-U2SB0-300-1SS1
LM-U2SB0-420-1SS1

LM-U2PBD-15M-1SS0 
LM-U2PBF-22M-1SS0 
LM-U2P2B-40M-2SS0 LM-U2S20-300-2SS1
LM-U2S20-480-2SS1

LM-U2P2C-60M-2SS0 
LM-U2P2D-80M-2SS0 
Linear servo motor Servo amplifier MR-J5W2-_ Servo amplifier MR-J5W3-_
Primary side (coil) Secondary side
(magnet)
22G 44G 77G 1010G 222G 444G
LM-U2PAB-05M-0SS0 LM-U2SA0-240-0SS0
LM-U2SA0-300-0SS0
LM-U2SA0-420-0SS0

LM-U2PAD-10M-0SS0 
LM-U2PAF-15M-0SS0 
LM-U2PBB-07M-1SS0 LM-U2SB0-240-1SS1
LM-U2SB0-300-1SS1
LM-U2SB0-420-1SS1

LM-U2PBD-15M-1SS0 
LM-U2PBF-22M-1SS0 
LM-U2P2B-40M-2SS0 LM-U2S20-300-2SS1
LM-U2S20-480-2SS1

LM-U2P2C-60M-2SS0 
/