Extech Instruments MO265 User manual

Category
Measuring, testing & control
Type
User manual
USER MANUAL
Dual Moisture Meter Pro
Pin / Pinless Moisture Meter with remote probe
Model MO265
MO265-en-GB_V1.2 8/16
2
Introduction
Congratulations on your purchase of the Extech MO265 Moisture Meter. The MO265 detects
moisture in wood and other materials such as particle board, carpeting, and ceiling/bathroom tiles
using the non-invasive method (pinless); the MO265 also measures moisture in sheet rock and
other building materials using the pin method. The remote probe can also be used to make pin
measurements. This meter is shipped fully tested and calibrated and, with proper use, will provide
years of reliable service.
Features
%WME (wood moisture equivalent) pin moisture reading
Relative (REL) pinless moisture reading for non-invasive measurement
Remote probe measurements
Digital LCD readout with backlighting feature and tri-color LED bargraph
Quickly indicates the moisture content of materials
Pinless measurement depth to 0.75" (22mm) below the surface
Electro-magnetic sensing technology for pinless operation
Built-in calibration check and calibration zero
Replaceable measurement electrode pins
Low battery indication
Cap protects pins during storage
Cap can be snapped onto the side of the housing during use
Complete with 9V battery, replacement pins, protective cap, and pouch case
MO265-en-GB_V1.2 8/16
3
Description
Meter Description
1. Electrode pins protective cap (pins underneath)
2. LCD display
3. Tri-color Bargraph
4. HOLD / POWER key
5. Protective cap attachment
6. Protective cap holders
7. MODE button
8. Remote probe connector plug
9. Remote Probe
10. Measurement pins
Notes:
Battery/Spare Pin compartment located on the rear of
the instrument
Electrode pins located beneath the protective cap
Calibration source located at the top of protective cap
A tripod mount is located on the rear of the remote probe head
LCD Display Description
1. Measurement reading
2. Battery status
3. Audible alert icon
4. Measurement mode
5. Display HOLD icon
Bargraph Display Description
The bargraph indicates WET / DRY measurements using three LED colors: Green (for dry),
Amber (for moderate moisture), and Red (for very moist). As the reading moves up the
bargraph scale from the DRY indicator to the WET indicator, the LED color changes from
green, to amber, and then to red.
MO265-en-GB_V1.2 8/16
4
Operation
Electrode Pins
The electrode pins are replaceable. To insert or replace the pins refer to the illustration and
instructions below. Replacement pins are stored in the battery compartment at the rear of the
meter.
a) Remove the protective cap at the top of the meter by pushing it toward the back of the
meter.
b) To remove the pins, loosen the locknut at the base of the electrode pins
c) Install the new pins and tighten the locknuts
d) Replace the protective cap
1. Electrode pins
2. Locking nuts
3. Threaded posts
4. Electrode jacks at top of meter
Pin Measurements
1. Remove the protective cap to expose the electrode pins. The cap snaps off easily if it is
pushed towards the rear of the meter. The cap can be affixed to the side of the meter using
the protective cap holders (6).
2. Press the
key to turn the meter ON / OFF.
3. Press the MODE key to select the Wood Moisture Equivalent (%WME) mode of operation.
4. Carefully push the electrode pins a minimum of 0.07” (2mm) into the material under test.
Note that the pins should be inserted into wood perpendicular to the wood’s fiber structure.
For high moisture readings, it may take several minutes for the meter reading to stabilize.
5. Take several readings in several locations on the material for the best representation of the
amount of moisture present.
6. Read the measurement values on the LCD digital display and the LED bar graph
7. Replace the protective cap when finished.
CAUTION: The electrode measurement pins are extremely sharp. Use care when
handling this instrument. Cover the pins with the protective cap when the
instrument is not in use.
MO265-en-GB_V1.2 8/16
5
Pinless Measurements
See section on how a Pinless meter measures moisture.
1. Ensure that the protective cap is attached to the meter
covering the pins.
2. Press the
key to turn the meter ON.
3. Press the MODE key to select the Relative (REL) mode of
operation.
4. The pinless moisture detector is located at the rear of the
instrument, just behind the display. Place the meter so that
the sensor is touching the surface of the material under test.
5. Take several readings in several locations on the material
for the best representation of the amount of moisture present.
6. Read the measurement values on the LCD digital display and the LED bar graph.
Remote Probe Pin Measurements
IMPORTANT NOTE: The Remote Probe cannot be used at the same time as the meter probe.
Please use one probe or the other but not both at the same time.
1. Connect the Remote Probe to the right side of the meter using the RJ-11 plug at the end of
the Remote Probe cable.
2. Remove the protective cap from the remote probe to expose the electrode pins. The cap
snaps off easily if it is pushed long-wise to the side.
3. Press the key to turn the meter ON / OFF.
4. Press the MODE key to select the Wood Moisture Equivalent (%WME) mode of operation.
5. Carefully push the electrode pins a minimum of 0.07” (2mm) into the material under test.
Note that the pins should be inserted into wood perpendicular to the wood’s fiber structure.
For high moisture readings, it may take several minutes for the meter reading to stabilize.
6. Take several readings in several locations on the material for the best representation of the
amount of moisture present.
7. Read the measurement values on the LCD digital display and the LED bar graph
8. Replace the protective cap and disconnect the remote probe when finished.
Pinless
Sensor
MO265-en-GB_V1.2 8/16
6
Calibration Zero for Pinless Mode
1. Switch the meter to the Pinless mode of operation (REL mode).
2. Ensure that the meter is not near any objects or surfaces. Hold the meter near the bottom to
avoid contact with the pinless sensor.
3. Press and Hold the MODE button for 3 seconds until rEL appears in the display. Release
the MODE button and the display will blink for several seconds and then switch back to the
normal display mode.
4. The display should now read zero indicating that the calibration is complete.
5. If an E32 error is displayed, try the zero calibration again with the pins further away from any
objects or surfaces.
Calibration Check for Pin Mode
1. Switch the meter to the Pin mode (%WME).
2. The two calibration check points are located in the holes at the top of the protective cap.
3. Insert the electrode pins into the two holes at the top of the protective cap to make contact
with the test circuit.
4. The display should read between 17.0 to 19.0 %WME, indicating that the calibration is
verified.
How a Pinless Moisture Meter Measures Moisture
A pinless meter is a “relative” or unit-less measurement device.
Unlike the PIN type moisture meter that measures %WME or electrical resistance, the Pinless meter
measures an electrical property of the material called relative permittivity. A pinless meter uses an
Electromagnetic signal to check the permittivity of a material.
The proper way to use a pinless meter is to make a measurement of a material of a known dryness.
Then make a measurement of an item of the same material, thickness, and construction of unknown
moisture content. Any rise in reading indicates moisture, or the presence of some other conductor
or high permittivity material (a metal stud behind the wall would produce higher readings).
Making multiple measurements over the suspected area is recommended to get an average reading
of the material. Practice and experience will help you to get a feel for the moisture content in that
material.
MO265-en-GB_V1.2 8/16
7
LCD Backlight ON/OFF
With the meter switched ON, pressing and holding both front panel buttons (MODE and HOLD)
switches the LCD backlight ON and OFF.
Data Hold feature
The Data Hold function freezes the reading in the display. Press the HOLD key momentarily to
activate the Data Hold function. The reading will freezee and the ‘key’ display icon will appear.
Press the HOLD key again to exit the Data Hold function (the ‘key’ display icon will switch off).
Meter Setup
To enter the setup mode:
With the meter switched OFF, press and hold both front panel buttons (MODE and HOLD
buttons) simultaneously for two seconds. The display should now read ‘0 = x’ where ‘0’ is the
OPTION and ‘x’ is the SETTING.
Use the MODE (right arrow) button to change the SETTING.
Use the HOLD button to scroll through the OPTIONS.
The available OPTIONS and SETTINGS:
OPTIONS SETTINGS SET-UP INFORMATION
0 0 Switches all settings to ‘0’ (Factory Default*)
1 Others settings can now be changed. In addition, Backlight
switches ON for 30 seconds and then automatically switches
OFF.
1 0 Audible alert beeps with increasing frequency from a nominal
17.0 (REL) or 17% (WME) measurement value upwards
1 Audible alert divided into 3 frequency levels
2 Audible alert beeps when user switches from one mode to
another
3 Beeper OFF. Audio alert display symbol switches OFF
2 0 Auto Switch OFF is not active. User must manually switch the
unit OFF
1 Auto Switch OFF active. Switches OFF after 3 minutes
2 Auto Switch OFF active. Switches OFF after 5 minutes
3 Auto Switch OFF active. Switches OFF after 10 minutes
3 0 Backlight OFF
1 Backlight ON
*FACTORY DEFAULT SETTINGS: 0=0, 1=0, 2=0, 3=0
MO265-en-GB_V1.2 8/16
8
Battery Replacement
If the instrument does not switch ON or displays the low battery symbol, replace the battery as
follows:
1. Slide off the rear battery compartment cover
2. Replace the 9V battery
3. Secure the battery compartment
4.
Neverdisposeofusedbatteriesorrechargeablebatteriesinhouseholdwaste.
Asconsumers,usersarelegallyrequiredtotakeusedbatteriestoappropriatecollectionsites,
theretailstorewherethebatterieswerepurchased,orwhereverbatteriesaresold.
Disposal:Donotdisposeofthisinstrumentinhouseholdwaste.
Theuserisobligatedtotake
endoflifedevicestoadesignatedcollectionpointforthedisposalofelectricalandelectronic
equipment.
Maintenance
Always keep the instrument dry
To clean, wipe the meter with a damp cloth. Use a mild detergent if necessary but never use
abrasives or solvents.
Prevent dirt from accumulating at the electrode pins
Specifications
Display Backlit LCD digital display and tri-color LED bar graph scale
Resolution 0.1%
Accuracy Pin mode: ± (5% rdg + 5 digits)
Pinless mode is a relative reading only
Measurement principle Electrical resistance (pins)
Electromagnetic sensor (pinless)
Range 0.0 to 99.9 %Relative (pinless)
6.0 to 94.8 %WME (pins)
Electrode pin length 11mm (0.44”)
Electrode pin type Integrated, replaceable
Power supply 9V alkaline battery
Low Battery Indication Battery symbol displayed on LCD
Meter housing Impact-proof plastic
Operating Temperature 0 to 50
o
C (32 to 122
o
F)
Operating Humidity 80% Relative Humidity maximum
Dimensions 203 x 58 x 43mm (8 x 2.3 x 1.7”); not including remote probe
Weight 204g. (7.2 oz); not including remote probe
Copyright©20122016FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
ISO9001Certified
www.extech.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Extech Instruments MO265 User manual

Category
Measuring, testing & control
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI