Chore-Time MT1828B Installation & Operator's Instruction Manual

Type
Installation & Operator's Instruction Manual

This manual is also suitable for

Air Speed Sensor
Installation & Operator’s Instruction Manual
Introduction
The Airspeed Sensor is used to measure the air speed in a tunnel ventilated building. Using this equipment
for any other purpose or in a way not within the operating recommendations specified in this manual will
void the warranty and may cause personal injury.
Safety
DANGER !
Electrical Hazard
Disconnect electrical power to the
Control and to ALL electrical
devices connected to the Control's
Relay Box before installing the
update kit! Failure to disconnect
power to equipment connected to
Relay Box could result in personal
injury.
MT1828BMay 2017
CTB Inc. Warranty
CTB Inc. Warranty Air Speed Sensor
2
MT1828B
CTB Inc. warrants each new product manufactured by it to be free from defects in material or workmanship for
one year from and after the date of initial installation by or for the original purchaser. If such a defect is found
by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option, (a) repair or
replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser
the original purchase price, in lieu of such repair or replacement. Labor costs associated with the replacement
or repair of the product are not covered by the Manufacturer.
Conditions and Limitations
1. The product must be installed by and operated in accordance with the instructions published by the
Manufacturer or Warranty will be void.
2. Warranty is void if all
components of the system are not original equipment supplied by the Manufacturer.
3. This product must be purchased from and installed by an authorized distributor or certified representative
thereof or the
Warranty will be void.
4. Malfunctions or failure resulting from misuse, abuse, negligence,
alteration, accident, or lack of proper
maintenance shall not be considered defects under the Warranty.
5. This Warranty applies only to sys
tems for the care of poultry and livestock. Other applications in industry
or commerce are not covered by this Warranty.
The M
anufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer
or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein
include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders,
lost income, increased overhead, labor and incidental costs and operational inefficiencies.
THIS WARRANTY CONSTITUTES THE MANUFACTURER’S ENTIRE AND SOLE WARRANTY AN
D
THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO
MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR
QUALITY OF THE PRODUCT FURNISHED HEREUNDER.
CTB Inc. product Distributors are not authorized to modify or extend
the terms and conditions of this Warranty
in any manner or to offer or grant any other warranties for CTB Inc. products in addition to those terms expressly
stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The Manufacturer
reserves the right to change models and specifications at any time without notice or obligation to improve previous
models.
Effective: May 2017
Thank You
The employees of CTB Inc. would like to thank your for your recent purchase. If a problem should arise, your CTB
distributor can supply the necessary information to help you.
Assembly
Air Speed Sensor Assembly
MT1828B
3
Attach the Airspeed Sensor (Item 1, Figure 1) to the Mounting Bracket (Item 2) using the nuts and washers
attached to the Sensor itself.
1
1
1
2
Item Description
1Air Speed Sensor
2 Mounting Bracket
3 Washer (provided)
4 Nut (Provided)
Figure 1. Air Speed Sensor Assembly
Attach the Mounting Bracket (Item 1, Figure 2) to a 2" x 4" board (Item 2) using
(3) #8 screws (Item
3) provided. It is recommended that the board be connected to the ceiling using a Hinge (not
provided). This is to allow the Sensor to be lifted out of the way during cleanout.
Item Description
1 Mounting Bracket
2 2x4 Board
3 #8 Screw
4 Hinge (Not provided)
Figure 2. Air Speed Sensor Mounting
2
3
4
1
Assembly Air Speed Sensor
4
MT1828B
The Air Speed Sensor (Item 1, Figure 3) should be located approximately 50 feet from the Tunnel Fans, 3 feet
off the floor in the center of the building. Do not mount the Sensor to the wall. The Sensor needs to have a rigid
mounting for a more accurate airspeed measurement. The Airspeed Sensor should be oriented so that the axis of
the Sensor is vertical and the three plastic cups spin horizontally.
Approx. 50’ [15.2 Meters]
Figure 3. Air Speed Sensor location
Tunnel
Fans
1
Center of House
Floor
3’ [1 Meter]
1
Axis Vertical
Item Description
1 Air Speed Sensor
Wiring
DI1
12V
2
(DI) of your Choice
GREEN
BROWN
WHITE
GREEN
BROWN
WHITE
Item Description
1 Airspeed Sensor
2 I/O Board Digital Input (DI)
terminal of your Choice
3 Airspeed Translation Box
1
3
The Airspeed Translation Box can be placed anywhere in line between the Control and the
Sensor. Recommended locations would be either right next to the Control or mounted on
the Mounting Bracket of the Sensor.
Air Speed Sensor Wiring
MT1828B
5
Parts List
Item Description Part No.
1 Air Speed Sensor 49350
2 Mounting Bracket 49351
1
2
Made to work.
Built to last.
Revisions to this Manual
Page No. Description of Change ECO
Added Wiring Diagram 32672
Contact your nearby Chore-Time distributor or representative for
additional parts and information.
CTB Inc.
P.O. Box 2000 • Milfor
d, Indiana 46542-2000 • U.S.A.
Phone (574) 658-4101 • Fax
(877) 730-8825
Email: ctb@ctbinc.com • Internet: http
//www.ctbinc.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Chore-Time MT1828B Installation & Operator's Instruction Manual

Type
Installation & Operator's Instruction Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI