Chore-Time MT2340A CHORE-TRONICS® IDM Board Operating instructions

Type
Operating instructions
Caution, Warning and Danger Decals have been placed on the equipment
to warn of potentially dangerous situations. Care should be taken to keep this
information intact and easy to read at all times. Replace missing or damaged
safety decals immediately.
DANGER: Electrical Hazard
Disconnect electrical power before inspecting or servicing equipment unless
maintenance instructions specifically state otherwise. Ground all electrical
equipment for safety. All electrical wiring must be done by a qualified electrician in
accordance with local and national electric codes. Ground all non-current carrying
metal parts to guard against electrical shock. With the exception of motor overload
protection, electrical disconnects and over current protection are not supplied with
the equipment.
Chore-Tronics IDM
Board
Instruction
MT2340AMarch 2009
2
MT2340A
Pulsed Water Meter and Feed Scale Wiring
The pulsed water meters and feed scales require non-shielded 20 gauge twisted pair wire. This wire is
available through Chore-Time (part number 42208). When routing this wire in the house be sure to keep
the wire a minimum of 12" away from line voltage wiring. If there is a need for the sensor wire to cross
line voltage wires, cross them at a 90 degree angle to each as shown below.
Connect Pulsed Water Meters #2 through #9 to the IDM board terminals as shown in Figure below using
the Twisted Pair Wire. If a water meter not sold by CTB, inc. is used make sure that has a dry contact
output connection. DO NOT use a water meter that sends voltage out with every pulse. Note the correct
position of the IDM Board Dip Switches.
Non Shielded Twisted Pair Wire
Line Voltage Wire
MT1820-014 5/04
Pulsed
Water
Meter #5
Pulsed
Water
Meter #4
Pulsed
Water
Meter #3
Pulsed
Water
Meter #2
Pulsed
Water
Meter #9
Pulsed
Water
Meter #8
Pulsed
Water
Meter #7
Pulsed
Water
Meter #6
ON
12345
Water Meter
Non Shielded
Twisted Pair Wire
IDM Board
Dip Switches
IDM Board
MT2340A
3
Using the blue and brown wires from the Feed Scales Connect Feed Scales #2 through #9 to the IDM
board terminals using Twisted Pair Wire (See Figure below). Note the correct position of the Dip
Switches. See Feed Scale Manual MT1811 for additional information if needed.
Airspeed Meter Wiring
The Airspeed Meter connects to the last digital input terminal on the IDM board using a three conductor
wire with a shield (See Figure below for Detailed Wiring). See Air Speed Meter manual for installing
the Wind Speed Sensor inside the house.
MT1820-015 05/04
Feed Scale
#5
Feed Scale
#4
Feed Scale
#3
Feed Scale
#2
Feed Scale
#8
Feed Scale
#7
Feed Scale
#6
ON
12345
IDM Board
Non-Shielded
Twisted Pair
Wire
Feed
Scale
IDM Board
Dip Switches
Green
Brown
Black
Item Description
1Air Speed Meter
2 Last Input Terminal
3 Non Shielded Twisted Pair
White
2
Airspeed Meter
Non-Shielded
Twisted Pair
Wire
Last Input
Terminal
4
MT2340A
Model 32 & Model 40 Optional Boards Wiring (Page 1
ON
L
2
F
R
O
M
C
O
N
T
R
O
L
L
E
R
B
R
E
A
K
E
R
L
1
F
R
O
M
C
O
N
T
R
O
L
L
E
R
B
R
E
A
K
E
R
NO NCC
BLK RED
FNET
OS
STATIC
NET
ALARM
-I/O+
PRESSURE
D2
S4S3S2
P2 D1P1
S1
+VRH
GND
S5
HUMIDITY
RELATIVE
S6
GND
EXT
24V
5V
L2L1
TO BACKUP BOX
GROUND WIRE TO I/O BOARD
INSTALL IF NOT INCLUDED
I/O BOARD
T
O
C
-
C
E
N
T
R
A
L
ON
3
2
1
SECOND I/O BOARD
L1 L2
5V
24V EXT
GND
S6
S5
GND
RH
+V
S1
P1 D1P2
S2
S3
S4
D2
PRESSURE
-I/O+
ALARM
NET
STATIC
OS
FNET
REDBLK
C
NC
NO
RED WIRE
GREEN WIRE
BLACK WIRE
DIP SWITCH
SETTINGS
12
DIP SWITCH #2
MUST BE ON IF
AT END OF I/O
NET
Continued to facing page
MT2340A
5
Model 32 & Model 40 Optional Boards (Page 2)
IARM BOARD
IDM BOARD
TWISTED PAIR WIRE
(PART NO. 42208)
120 OHM RESISTOR
REQUIRED AT EACH
END OF I/O NET.
5
4
3
ON
1
2
2
1
ON
3
4
5
DIP SWITCH
SETTINGS
`
DIP SWITCH
SETTINGS
Continued from facing page
Model 32/40 2nd I/O, IDM and IARM Board Placement
(Before April 2003)
Model 32/40 2nd I/O, IDM and IARM Board Placement
(After April 2003)
CTB Inc.
P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A.
Phone (574) 658-4101 • Fax (877) 730-8825
Email: [email protected] • Internet: http//www.ctbinc.com
IARM
I/O BOARD
2ND I/O BOARD
IDM
BOARD
STATIC
PRESSURE KIT
MAIN BOX
Mount the Second I/O Board
To the metal base plate
With the black plastic
Mounting Hardware
Supplied with the kit.
Mount the IARM Board
To the metal base plate
with the white plastic
Mounting hardware
Supplied with the kit.
Mount the IDM Board
To the metal base plate
with the white plastic
Mounting hardware
Supplied with the kit.
I/O Board
2ND I/O BOARD
IARM
BOARD
IDM BOARD
STATIC PRESSURE
KIT
Mounting Holes:
Second I/O: Drill 6-1/4" Holes
IARM Board: Drill 6-3/16" Holes
IDM Board: Drill 7-3/16" Holes
Place edge of Board
at the edge of the
Backplate
Approx. 2.5"
from bottom of
Main Box
Approx. 6.5"
from bottom of
Main Box
Approx. 2"
from side of
Main Box
Place edge of
Board at edge
of the Backplate
.5" spacing