Valcom V-1134 All Call One-Way Page Unit Operating instructions

Type
Operating instructions
VSP-V-1134
Issue 7
1947114
V-1134
ALL CALL ONE-WAY PAGE UNIT
INTRODUCTION
These instructions provide the specifications and
information necessary to install, operate, and maintain
the V-1134, All Call One-Way Page Unit.
SPECIFICATIONS
Purpose
To provide one-way all call page to 34 zones when
used with the V-136RTHF 36 zone page control unit.
Applications
V-136RTHF 36 zone handsfree control unit
Features
One-way all call amplification to 34 zones
Dial 0 for all call
Automatic release of all call unit with two
telephones off hook
Easy installation - 30" plug ended cable provided
Built-in volume control for all call level
NOTE: Unit replaces stations 0 and 39 on 36 zone
control units.
Dimensions/Weight
7.13"H x 5.75"W x 2.13"D
(18.11cm H x 14.61cm W x 5.41cm D)
4 lbs. (1.8 kg)
Power Requirements
-24 Vdc B battery 1 amp maximum
Output
400 milliwatts per speaker
DESIGN
General
This unit provides one-way all call page to the
V-136RTHF. The functions and operation of the
intercom unit remain the same as without the all call
unit with exception that dialing "0" energizes the all
call unit and permits a one-way page to all stations of
the intercom.
INSTALLATION
Precautions
All precautions have been taken at the factory to insure
that the equipment functions properly. To insure
proper operation and to prevent equipment damage,
please observe the following:
a) Unplug the power supply before connecting any
wires or cables to the control unit connecting
block.
b) Do not locate the control unit more than 5 feet
from the power supply or closer than 18 inches.
c) Do not use a lamp tester to check signals, use a
voltmeter. A lamp tester when first applied is a
short circuit to electronic circuits.
d) Do not apply power to the control unit until all
connections have been double-checked.
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com
2947114
Mounting
Mount the V-1134 close to the V-136RTHF control
unit allowing enough room for the amphenol
connectors. NOTE: The cable supplied with the unit is
30" long. If units are separated by more than 30",
additional cable may be required.
Cabling
NOTE: In a mixed system of Bell/Buzzer and
voice signaling, stations 30-29, 0, and 5-9
must be voice signaling. Bells or buzzers
must be connected as excluded speakers
(See Figure 2).
a) In a new installation, complete all steps of the
installation procedure as shown in the instruct-
ions for the V-136RTHF, combination.
Connect the 25 pair intercom cable from the 66
type split block to the amphenol on the V-1134
marked "to 66 block."
b) In an existing system without all call, remove the
intercom cable from the V-136RTHF and plug it
into the amphenol on the V-1134 marked "to 66
block."
c) If all speakers are to receive all call, refer to
Figure 1. One end of the 30" cable supplied with
the V-1134 should be plugged into the amphenol
marked "to intercom." The other end should plug
into the V-136RTHF intercom unit.
d) If some stations are to be excluded from the all
call, refer to Figure 2. Punch down two 25
pair female amphenol ended cables on a 66 type
solid block. Plug one cable to the V-1134 "to
intercom" amphenol and plug the second cable to
the V-136RTHF. Connect excluded speakers to
the appropriate ICM number on the solid block
and to the common speaker return on the split
block. Connect non-excluded speakers as shown
in the V-136RTHF installation instruction.
NOTE: Do not connect speakers to stations 0
or 39.
Cross Connections
a) If using the V-1134 with the V-136RTHF,
perform the following:
Strap the Y/BN to the G/V on the "to 66 block"
25 pair cable.
Power Connections
The V-1134 requires no external power connections as
its power is derived from the power supplied to
the V-136RTHF. Care should be taken to make sure
that the power supply is capable of supplying the
increased current requirements when the V-1134 is in
use.
OPERATION
When the calling party goes off hook on the intercom
and dials "0", the intercom switching network closes a
contact for station "0". This contact connects a
resistive ground supplied by the Y/BN lead of the
V-1134 (ICM connector) back to the O/V lead of the
V-1134 (ICM connector). The V-1134 operates a
series of relays with transfer contacts and all stations
are transferred to the outputs of audio amplifiers. After
approximately 1 second the amplifiers are energized
and the calling party can make a one-way page to all
stations. If station "0" is not dialed, the V-136RTHF
units perform in the manner described in their Valcom
System Instructions with the speaker leads from the
control units going straight through normally closed
contacts in the V-1134.
TECHNICAL ASSISTANCE
When trouble is reported, verify that power is being
supplied to the unit and there are no broken
connections. Check voltages for proper polarity on the
crossconnect block. The table on the next page
identifies symptoms of some possible problems with
solutions.
If a spare unit is available, continue to troubleshoot by
substituting the spare unit for the suspected unit.
Assistance in troubleshooting is available from the
factory. When calling, you should have a VOM, a
telephone test set, several clip leads available and be
calling from the job site. Call (540) 427-3900 and ask
for Technical Support, or call (540) 427-6000 for
Valcom Automated Support or visit our website at
http://www.valcom.com.
The V-1134 is not field repairable. Valcom, Inc.
maintains service facilities in Roanoke, VA. Should
repairs be necessary, attach a tag indicating company
name, address, phone number, contact person, and the
nature of the problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com
3947114
TROUBLESHOOTING CHART
PROBLEMS PROBABLE CAUSES AND CORRECTIONS
All call feature inoperative.
All call inhibit feature inoperative.
No all call output or low volume.
All call clicks or stays operated.
Verify connection to proper plugs on V-1134. If plugs are reversed, intercom will
operate, but all call function will not.
Plug cable from crossconnect block directly into V-136RTHF bypassing V-1134 and
check for proper operation of intercom. If V-136RTHF does not work, refer to
VSP-136RTHF instruction.
Verify straps are in place on crossconnect field as outlined previously.
Verify straps are in place on crossconnect field.
Verify that a 5K ohm resistive ground appears at the W/G (pin 28) wire of the "to 66
block" cable when two or more phones are off hook on the intercom. Refer to the
V-136RTHF instruction.
Adjust all call volume on unit to desired listening level.
Ground on a speaker wire. Remove all speaker cables at main frame. Reconnect
one at a time and test.
V-136 RTHF
V-1134
To Intercom
To 66 Block
Station Numbers
Speaker Return
Split
Block
Speakers
V-136 RTHF
V-1134
To Intercom
To 66 Block
Station Numbers
Speaker Return
Split
Block
Speakers
Station Numbers
Excluded
Speakers
Connections required from V-136RTHF to V-1134 for all call to all speakers
Figure 1
Figure 2
Connections required from V-136RTHF to V-1134 for all call with excluded speakers
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com
4947114
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and
service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement,
repair or refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim,
2. the defect is not the result of damage, misuse, or negligence after the original shipment.
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service
charge plus parts and labor will be applied to units defaced or physically damaged),
4. freight charges for the return of products to Valcom are prepaid,
5. all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (Major repairs will
be subject to additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be
liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection
with the purchase, operation, or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the
carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the
F.O.B. point. Headquarters: In Canada
Valcom, Inc. CMX Corporation
1111 Industry Avenue 35 Van Kirk Drive #11 and 12
Roanoke, VA 24013 Brampton, Ontario L7A1A5
Phone: (540) 427-3900 Phone: (905) 456-1072
FAX: (540) 427-3517 FAX: (905) 456-2269
W/BL
BL/W
W/O
O/W
W/G
G/W
W/BR
BR/W
W/S
S/W
R/BL
BL/R
R/O
O/R
R/G
G/R
R/BR
BR/R
R/S
S/R
BK/BL
BL/BK
BK/O
O/BK
BK/G
G/BK
BK/BR
BR/BK
BK/S
S/BK
Y/BL
BL/Y
Y/O
O/Y
Y/G
G/Y
Y/BR
BR/Y
Y/S
S/Y
V/BL
BL/V
V/O
O/V
V/G
G/V
V/BR
BR/V
V/S
S/V
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
39
14
40
15
41
16
42
17
43
18
44
45
20
46
21
47
22
48
23
49
24
37
12
38
13
19
50
25
TIP
RING
LAMPS
LAMPS SUP
INHIBIT
PC
STA 10
STA 11
STA 12
STA 13
STA 14
STA 15
STA 16
STA 17
STA 18
STA 19
STA 20
STA 21
STA 22
STA 23
STA 24
STA 25
STA 26
STA 27
STA 28
STA 29
STA 30
STA 31
STA 32
STA 33
STA 34
STA 35
STA 36
STA 37
STA 38
ALL CALL
STA 5
STA 6
STA 7
STA 8
STA 9
SIG IN 1
SIG IN 2
AUX 1
AUX 2
A GND
A BATT
B GND
B BATT
CONNECT THIS SIDE TO 66 BLOCK
All Call
Volume
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
39
14
40
15
41
16
42
17
43
18
44
45
20
46
21
47
22
48
23
49
24
37
12
38
13
19
50
25
25
CONNECT THIS SIDE TO INTERCOM
All Call
Inhibit
Control
All Call
Initiate
Control
NC-
Strap Y/Bn to common
side of all speakers
This unit to be used
with V-136RTHF
All Call Volume
Connection to ICM is
made via cable furnished.
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Valcom V-1134 All Call One-Way Page Unit Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI