Lithonia Lighting Kar Installation guide

Type
Installation guide

This manual is also suitable for

Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: RJ5207103 Rev B
Revision Date: 1-21-10
Installation Instructions
DA12P & DAD12P
SAVE THESE INSTRUCTIONS
WARNING
To reduce the risk of death, injury or property damage from fire, electric shock, cuts,
abrasions, falling parts, and other hazards:
Service of the equipment must be performed by qualified service personnel.
Installation and maintenance must be performed by a person familiar with the construction and
operation of this product and any hazards involved. All applicable codes and ordinances must
be followed.
Read this document before installing, servicing, or maintaining this equipment or installing a
lamp. These instructions do not cover all installation, service, and maintenance situations. If
your situation is not covered, or if you do not understand these instructions or additional
information is required, contact Lithonia Lighting or your local Lithonia LIghting Distributor.
Read and follow all warnings and instructions provided by the lamp manufacturer.
WARNING
Before installing, servicing, or maintaining this equipment, follow these general precautions.
To reduce the risk of electrocution:
Make sure the equipment is properly grounded.
Always de-energize the circuit and/or equipment before connecting to, disconnecting
from, or servicing the equipment.
To reduce the risk of fire:
Keep material away that can burn from hot lamp.
Make sure lamps are correctly installed.
Use supply conductors with a minimum installation temperature rating as specified on
equipment.
To reduce the risk of personal injury from cuts, abrasions, or falling parts:
Wear gloves to prevent cuts or abrasions from sharp edges when removing from
carton, handling and maintaining this equipment.
Do not use abrasive materials, glass cleaners or other solvents on reflector or lens.
These substances may damage equipment and cause parts to eventually break and
fall.
Do not install a damaged fixture.
CAUTION: Observe lamp manufacturers recommendations and restrictions on lamp operation,
including but not limited to ballast type, burning position, replacement and cycling. Use only lamps that
comply with applicable ANSI standards.
NOTICE: If lamp is marked it contains mercury. Follow disposal laws. See
www.lamprecycle.org
Lithonia Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for claims arising out of
improper or careless installation or handling of this product.
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
DISCONTINUED
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: RJ5207103 Rev B
Revision Date: 1-21-10
Installation Instructions
DA12P & DAD12P
1. Insert the pole mounting plate inside pole or tenon adaptor, aligning the three (3) mounting holes in the plate with the (3)
mounting holes provided on the pole. If poles have not been pre-drilled, use Lithonia Drilling Template #5, as a guide. Insert and
align gasket provided between the arm and the pole, as shown below. Align one end of mounting arm to pole mounting holes.
Insert the two attachment bolts through the arm and gasket until they engage the pole mounting plate. Tighten both bolts
securely.
2. To mount fixture, align gasket to mounting holes between the fixture housing and mounting bracket. Insert two (2) 1-3/4"
attachment bolts through mounting arm and into housing, being careful to align gasketing between fixture housing and mounting
arm. Install split lock washer and hex jam nuts on the bolts inside fixture housing and tighten securely. Check to assure fixture is
level and plum.
3. To adjust mounting arm, remove both center hole plugs located at arm's pivot point. Loosen the single bolt and nut assembly,
being careful not to allow fixture housing to drop. Set the mounting arm at desired angle of uptilt and tighten the center nut and
bolt assembly securely. This mounting arm has raised degree scales located on the top and bottom sides of arm, divided into 5o
increments, with a maximum 30° tilt. Install both hole plugs to complete installation.
WARNING: Options are to be installed in the field. Be sure the electrical components are not energized during maintenance or
installation of product. DO NOT alter fittings when mounting the fixtures. Recheck all connections and bolts to insure they will not
loosen due to vibration.
Note: This drawing is not to scale and should be used for dimensional purposes only.
DA12P or DAD12P may be used on round or square pole.
DA12P is for use with square edged fixtures.
DAD12P (shown) is for use with rounded edged fixtures.
Fixture
Gasket
Split lockwasher
Hex jam nut
Hole plug
Handhole cover
Pole
mounting
plate
Pole
Gasket
Adjustable mounting arm
(ships in two pieces)
Handhole cover
Hole plug
©2001 Acuity Brands Lighting, Inc.
All Rights Reserved. Rev. 01/10
DISCONTINUED
  • Page 1 1
  • Page 2 2

Lithonia Lighting Kar Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI