Equinox Systems Midas Spot User manual

  • Hello! I am an AI chatbot trained to assist you with the Equinox Systems Midas Spot User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Order code: EQLED072
Midas Spot
User Manual
www.prolight.co.uk Midas Spot User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE INITIAL START-UP!
• Beforeinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Oneyearfromdateofpurchase.
www.prolight.co.uk Midas Spot User Manual
3
Product overview & technical specications
TheMidasSpotisarevolutionaryLEDpoweredmovinghead.Ittakesthe
LEDoutputfroma60Wsourcetothenextlevelallwithinanamazingly
compactxture.TheMidasSpothasanoutputcomparabletoa250W
dischargexture.MuchfasterthanmanyothermovingheadstheMidas
Spotnotonlymoveswithagilityitalsokeepsperfectsynchronisation
thankstoitsautomaticpan/tiltcorrection.ThemightypowerofitsLED
source,combinedwith7dichroiccolours,atri-colourlterplus
openand7rotating,interchangeablegobosandtheadditionofa
3facetrotatingprismalongwithmotorisedfocusmakesthe
MidasSpotaspectaculareffectinanyapplication.
•1x60WwhiteLED
•Beamangle:1
•16,000Lux@2m
•4kHzrefreshrate
•Motorisedfocus
•3facetprism
•Gobowheel:7rotatingreplaceablegobos+open
(2additionalgobossupplied)
•Colourwheel:7colours+tri-colourlter+open
•DMXchannels:1/10or13selectable
•Auto,soundactiveandmaster/slavemodes
•Pan/tiltautocorrection
•16-Bitpan/tiltpositioning
•Pan:540°,Tilt:270°
•0-100%dimmingandvariablestrobe
•Suppliedwithquickreleaseomegaclamp
•Jogwheelmenuwith2”LCDdisplay
•PowerCONinput/output
•3-PinXLRinput/output
•Fancooled
Midas Spot
Specications Midas Spot
Powerconsumption 105W
Fuse T2A250V
Powersupply 100~240V,50/60Hz
Dimensions 365x242x147mm
Weight 6.9kg
Ordercode EQLED072
0m 1m 2m 3m 4m 5m
16° - Lux 64000 16000 7110
16°
4000 2560
365mm
242mm 147mm
www.prolight.co.uk Midas Spot User Manual
4
Technical specications
01-Earthpoint
02-LCDdisplay
03-Jogwheel
04-LEDmodeindicators
05-On/offswitch
06-3-PinDMXinput
07-3-PinDMXoutput
08-PowerCONinput
09-PowerCONoutput
10-FuseT2A250V
11-Omegabracketplate
12-Fancoolingvents
Inthebox:1 x xture,
1 x omega clamp,
1 x power cable
& 1 x user manual
MIDAS SPOT
M
E
N
U
DMX
MASTER
SLAVE
SOUND
POWER INPUT:
100-240V~50/60Hz
FUSE: T2A 250V
ON
OFF
DMX INPUT DMX OUTPUT
www.prolight.co.uk
POWER OUTPUT:
100-240V~50/60Hz
12
01
10
05
02 1104 03 08 09 06 07
12
www.prolight.co.uk Midas Spot User Manual
5
Rotating Gobo Replacement:
Thextureissuppliedwith7rotating,replaceablegobos.Seebelowforinstallationinstructions.
1)Disconnectandisolatefromthepowerthen
placethextureonaatsurfaceandunscrew
theheadshell.
2)Removetheheadshellfromthehead.
3)Carefullyremoveoneofthegobotraysby
liftingslightlyandpullingtowardsyoureleasing
thetrayfromthespringclip.
4)Nowyoucanremovethecirclip,followedby
thegobofromthegobotray.Replacethegobo
andtthecirclipbackintothetray.
5)Placethegobotrayback
intothegobowheelbyslidingit
backunderthespringclipand
pushingitdownintothewheel.
6)Placetheheadshellback
ontothehead.
7)Tightenthescrewsuntilthe
headshellissecure.
Rotating Gobo Replacement
www.prolight.co.uk Midas Spot User Manual
6
Operating instructions
Control Panel Menu:
TheLCDcontrolpanelsituatedonthefrontofthextureallowstheusertoaccessthemenusystemto
adjustthexturessettings.
Whentheunithasbeenpoweredonitwillshow“Wait...”followedby“Equinox Midas Spot”.
Thexturewillthenreturntoitshomescreen.
Toaccessthemainmenuturnthejogwheelclockwiseoranti-clockwiseuntilthemenurequiredis
highlighted.Pressingthejogwheelononeoftheseoptionsallowsyoutoaccessthesubmenuwhere
youcanturnthejogwheelclockwiseoranti-clockwisetoselecttheoption/valuerequired.
Oncetheoption/valuehasbeenselectedpressthejogwheeloncemoretoconrmthesetting.
Thereare4LEDindicatorsonthefrontpanelofthexture:
DMX-ThisLEDindicatorwillashwhentheunitisreceivingaDMXsignal.
MASTER-ThisLEDindicatorwillilluminatewheninMastermode.
SLAVE-ThisLEDindicatorwillashwheninSlavemode.
SOUND-ThisLEDindicatorwillashwheninSoundmode.
MIDAS SPOT
M
E
N
U
DMX
MASTER
SLAVE
SOUND
www.prolight.co.uk Midas Spot User Manual
7
Operating instructions
Main Menu Sub Menu Options/Values Description
(Default Settings in BOLD)
1)DMXAddress 001-512 DMXAddressSetting
2)ChannelMode
1Ch(1channelmode)
DMXChannelSetting10Ch(10channelmode)
13Ch(13channelmode)
3)ShowMode
Show01-Show08
ForwardFacingShow
Built-inPrograms
4)SlaveMode
Slave1 SlaveModeSetting
Slave2 AutoMode
5)SoundMode
On
SoundMode/Settings
Off
Sens 000-255
Exit
6)ManualControl
1:Pan 00000-65535
ManualControlMode
2:Tilt 00000-65535
3:Dimmer 000-255
4:Strobe 000-255
5:Color 000-255
6:Gobo 000-255
7:GoboR 000-255
8:Prism 000-255
9:Focus 000-255
Exit
7)Settings
1:PanInvert
Normal
PanInverseSetting
Invert
2:TiltInvert
Normal
TiltInverseSetting
Invert
3:DimmerCurve
1:Square Law
DimmingCurveSettings
2:Linear
3:S-Curve
4:InvSquareLaw
4:DMXFail
1:Off
DMXFailSettings2:Hold
Exit
5:Display
1:Auto rotate
DisplayInverseSetting
2:Normal
3:Inverted
Exit
6:BackLight
1:On
DisplayBackLightSetting
2:Off
3:Adjust(01-10)
Exit
www.prolight.co.uk Midas Spot User Manual
8
Main Menu Sub Menu Options/Values Description
7)Settings
7:Reset
Yes
MotorReset
No
8:FactorySets
Yes
FactoryReset
No
9:AutoTest
Test
AutoTest
Exit
Exit ExitSubMenu
8)Calibrations
Password(088)
1:Pan 000--255
InitialHomePositionCalibration
2:Tilt 000--255
3:Color 000--255
4:Gobo 000--255
5:Focus 000--255
6:Default (Resetallhomepositionsto127/)
9)Version Vx.xx SoftwareVersion
Exit ReturntoHomeScreen
Operating instructions
www.prolight.co.uk Midas Spot User Manual
9
Operating instructions
Channel
Value Function
1 10 13
1 1 000-255 Panadjustment0-540°
2 000-255 Panneadjustment
2 3 000-255 Tiltadjustment0-270°
4 000-255 Tiltneadjustment
3 5 000-255 Pan/tiltspeed(fast-slow)
4 6 000-255 Masterdimmer(0-100%)
5 7
000-010 Nofunction
011-128 Randomstrobe(slow-fast)
129-255 Linearstrobe(slow-fast)
6 8
000-011 Open(white)
012-023 Red
024-035 Green
036-047 Blue
048-059 Yellow
060-071 Magenta
072-083 SkyBlue
084-095 Orange
096-107 Tri-colourFilter(RGB)
108-119 Splitcolour(Open/Red)
120-131 Splitcolour(Red/Green)
132-143 Splitcolour(Green/Blue)
144-155 Splitcolour(Blue/Yellow)
156-167 Splitcolour(Yellow/Magenta)
168-179 Splitcolour(Magenta/SkyBlue)
180-191 Splitcolour(SkyBlue/Orange)
192-203 Splitcolour(Orange/Tri-colourFilter(RGB))
204-215 Splitcolour(Tri-colourFilter(RGB)/Open)
216-235 Colourscrollclockwise(fast-slow)
236-255 Colourscrollanti-clockwise(slow-fast)
7 9
000-011 Open
012-023 Rotatinggobo1
024-035 Rotatinggobo2
036-047 Rotatinggobo3
048-059 Rotatinggobo4
060-071 Rotatinggobo5
072-083 Rotatinggobo6
084-095 Rotatinggobo7
DMX channel modes:
www.prolight.co.uk Midas Spot User Manual
10
Operating instructions
Channel
Value Function
1 10 13
7cont. 9cont.
096-107 Rotatinggobo7shake(slow-fast)
108-119 Rotatinggobo6shake(slow-fast)
120-131 Rotatinggobo5shake(slow-fast)
132-143 Rotatinggobo4shake(slow-fast)
144-155 Rotatinggobo3shake(slow-fast)
156-167 Rotatinggobo2shake(slow-fast)
168-179 Rotatinggobo1shake(slow-fast)
180-191 Open
192-223 Goboscrollclockwise(fast-slow)
224-255 Goboscrollanti-clockwise(slow-fast)
8 10
000-127 Goborotationindex
128-191 Goborotationclockwise(fast-slow)
192-255 Goborotationanti-clockwise(slow-fast)
9 11
000-080 Nofunction
081-255 3facetprism
10 12 000-255 Focus
13
000-009 Nofunction
010-020 Resetmotors(holdfor5seconds)
021-255 Nofunction
1
000-007 Nofunction
008-037 Show1
038-067 Show2
068-097 Show3
098-127 Show4
128-157 Show5
158-187 Show6
188-217 Show7
218-247 Show8
248-255 ForwardFacingShow
DMX channel modes cont:
www.prolight.co.uk Midas Spot User Manual
11
Operating instructions
Open Gobo1 Gobo2 Gobo3
Gobo4 Gobo5 Gobo6 Gobo7
Rotating gobos:
Gobosize:24mmØ
Imagesize:19.5mmØ
Additional rotating gobos (supplied):
Gobosize:24mmØ
Imagesize:19.5mmØ
www.prolight.co.uk Midas Spot User Manual
12
Installation
Installation:
1)BolteachclamptotheOmegabracket(s)withtheboltandlockingnutthroughoutthe
holeinthebracket.
2)FastentheOmegabracket(s)tothebottomofthemovingheadbasebyinsertingthe
quicklockfastenersintothereceivingholesinthebaseandtighten.
3)Hangthexturetothesupportthroughtheclampandsecurewiththelockingnuts.
Fastenthesafetycablethroughthebottomofthebaseandoverthesupport.
Attention:
•Alwaysensurethatthestructuretowhichyouareattachingthextureissecureandable
tosupportaweightof10timesthexturesweight.
•Alwaysuseasafetycablethatcabhold12timestheweightofthexturewheninstalling.
•Makesurethatthextureisrmlyattachedinawaythatnovibrationsormovementcould
occurduringoperation.
•Theequipmentmustbeinstalledbyprofessionalsandmustbeinstalledinanareawhere
itisoutofreachofpeopleandnoonecanpassbyorunderit.
www.prolight.co.uk Midas Spot User Manual
13
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m
www.prolight.co.uk Midas Spot User Manual
14
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (female)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (male)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup
www.prolight.co.uk Midas Spot User Manual
15
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
www.prolight.co.uk Midas Spot User Manual
16
/