W Audio AMP50 - XTR 1000, AMP50, AMP51, XTR-1000, XTR-1500 User manual

  • Hello! I am an AI chatbot trained to assist you with the W Audio AMP50 - XTR 1000 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Order codes:
AMP50 - XTR 1000
AMP51 - XTR 1500
XTR Series
Power Ampliers
User Manual
CH A
CLIP
PROTECT
CLIP
PROTECT
POWER
CH B
POWER
I
O
CH A
CLIP
PROTECT
CLIP
PROTECT
POWER
CH B
POWER
I
O
www.prolight.co.uk XTR Series Power Ampliers User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Immediatelyuponreceivingthisproduct,carefullyunpackthecartonandcheckthecontents
toensurethatallthepartsarepresent.
• Beforeinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Retainthecartonandallpackagingmaterials.
• Intheeventthattheequipmentmustbereturnedtothesupplier,itisimportantthat
theequipmentisreturnedintheoriginalcartonandpackaging.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,
itisnecessaryfortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Incaseofmalfunctionthisunitshouldbereturnedforserviceorinspection.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithcaution!
• Neverremovewarningorinformativelabelsfromthe
equipment.
• Donotopenormodifytheequipment.
• Donotconnectthisequipmenttoadimmer-pack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepowercablebytheplug.Neverpullouttheplugby
pullingthepowercable.
• Makesurethattheavailablevoltage
isbetween220V/240V.
• Makesurethatthepowercableisnevercrimped
ordamaged.Checktheequipmentandthepower
cableperiodically.
• Iftheequipmentisdroppedordamaged,disconnect
themainspowersupplyimmediately.Haveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastictemperature
uctuation(e.g.aftertransportation),donotswitchiton
immediately.Thearisingcondensationmightdamagethe
equipment.Leavetheequipmentswitchedoffuntilithas
reachedroomtemperature.
• Iftheproductfailstofunctioncorrectly,discontinueuse
immediately.Packsecurely(preferablyintheoriginal
packingmaterial),andreturntoyourdealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• WARRANTY:Oneyearfromdateofpurchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM MOISTURE,
RAIN AND LIQUIDS, AND
OUT OF DAMP/HUMID
ENVIRONMENTS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
www.prolight.co.uk XTR Series Power Ampliers User Manual
3
Product overview
Professionalpowerampliers
offeringsuperiorreliabilityand
performance,tosuitavariety
ofapplications.
•Shortcircuit,overloadand
thermalprotection
•Fancooled
•Groundlift
XTR Series Power Ampliers
Inthebox:
1 x power amplier,
1 x power cable
& 1 x user manual
CH A
CLIP
PROTECT
CLIP
PROTECT
POWER
CH B
POWER
I
O
CH A
CLIP
PROTECT
CLIP
PROTECT
POWER
CH B
POWER
I
O
Specications XTR 1000 XTR 1500
Outputpower1kHz,
THD+N≤0.5%
Stereo8Ω 2x350W 2x500W
Stereo4Ω 2x500W 2x750W
Frequencyresponse 20Hzto20kHz±1.0dB
Inputsensitivity 0.775V/1.0V/1.44V
S/Nratio(a-weighted,RMS) >95dB
Crosstalkatratedpoweroutput(8Ωat1kHz) >65dB
Dampingfactor(f=1kHz@8Ω) >150dB
Protectioncircuits Thermal,shortcircuit,overload,DCfaultprotection&ACpowersupplyfuse
LEDindicators Power,protect&clip
Connectors
Inputs:2xphonosockets,2x1/4”jacksockets
Outputs:2xlockingspeakerconnectors,2xbindingposts
Coolingsystem Lownoise,variablespeedfans
Powersupply AC240V/50Hz
Dimensions(HxWxD) 87x484x297mm 87x484x297mm
Weight 10.5kg 10.75kg
Ordercode AMP50 AMP51
www.prolight.co.uk XTR Series Power Ampliers User Manual
4
XTR 1000 & XTR 1500
dimensions
Product overview
484mm
87mm
264mm
297mm
426mm
www.prolight.co.uk XTR Series Power Ampliers User Manual
5
XTR 1000 & XTR 1500 front panel
XTR 1000 & XTR 1500 rear panel
Technical specications
01-ClipLEDs-TheseLEDsashambertoindicatewhen
theoutputoftheamplierhasreachedthemaximum,
andisrightontheedgeofclipping.Clippingisbadfor
speakersandshouldbeavoided.ItisokayiftheLED
blinksoccasionally.Itmeansthatthetransientpeaksof
themusicarejusthittingthefulloutputoftheamplier.
02-Gaincontrol-Thesetwoknobscontrolthelevelsof
Channels1and2.Usually,thesecontrolsaresetall
thewayup.Youmightturnthemdownslightlyifyou
havehigh-efciencyspeakers.Also,youcouldusethem
tocontrolthelevelofline-levelsourcessuchasaCD
playerconnecteddirectlytotheamplierwithouta
pre-amplierormixer.
Afteryouhavesetthelevelsforthemixer(orothersignal
source),adjustthelevelcontrolsontheamplierasthe
naladjustmenttosettheoverallvolumeforthesystem.
Instereoandmonomode,usebothlevelcontrolsto
controlthelevelsgoingtoeachspeaker.
03-PowerLED-ThisLEDilluminateswhentheamplier
isswitchedon.
04-ProtectLED-IfthisLEDisilluminatedduringoperation,
oneoftheprotectioncircuitsisactive.Pleasetakethe
amplieroutofoperationandhaveittested.
05-Powerswitch-Pressthisswitchtopowerthe
amplieron.
CH A
CLIP
PROTECT
CLIP
PROTECT
POWER
CH B
POWER
I
O
04 0205 03 0402
01 01
INPUTS
GROUNDLIFT
LIFT GND
B A
RIGHT LEFT
MAINS
T6.3 A
240V~50Hz
!
POWER AMPLIFIER
240V~50Hz
Serial no.
CAUTION!
Remove the mains power before opening
the unit. No user serviceable parts inside,
refer to qualied service personnel.
Protect the unit against moisture and heat.
Operating temperature range 0-40°C.
OUTPUTS
(4Ω min.)
01-¼”jackinputs-Theseinputsallowyoutoconnect
¼”unbalancedjackplugs
02-Phonoinputs-Theseinputsallowyoutoconnect
unbalancedphonoplugs
03-Therearethreewaysofconnectingyourspeakers:
Lockingspeakerconnectors,¼”jackorbindingposts.
Theconnectorsarewiredinparallel.(e.g.Channel1
bindingpost,jackandlockingspeakerconnectorsarein
parallelandthesameforchannel2).
04-Powercablesocket-Thisiswhereyouconnectthe
detachablepowercable.Connecttheotherendtoa
240VACoutlet.
05-Groundliftswitch-Thisswitchallowsthesignalground
orchassisgroundtobeseparatedincaseofaground
conict.Forthehighestsafetyoftheequipment,itis
recommendedtokeepthe“groundliftswitch”inthe
GNDposition.Incaseofagroundconictpleasesetthe
groundliftswitchtoGNDLIFT.
0201 01 040305
www.prolight.co.uk XTR Series Power Ampliers User Manual
6
Operating instructions
Rack installation
TheEPSeriesisbuiltfor19”racks.Therackyouuseshouldbea‘doubledoorrack’whereyoucanopen
thefrontandrearpanel.Whenmountingtheamplierintotherack,pleasemakesurethatthereis
enoughspacearoundtheamplier.
Becarefulwhenmountingtheamplierintotherack.Puttheheaviestproductsintothelowerpart
oftherack.Beawarethatfasteningtheamplierwithfourscrewsonthefrontpanelisnotenough.
Iftheracksarebeingtransportedorusedformobileuse,additionallyfastentheproductsby
connectingtherearbracketswiththesideorgroundbarsoftherack.Inthisway,theamplier
cannotbepushedbackwards.Thefrontpanelisnotdesignedtoabsorbaccelerationforces
occuringduringtransportation.
Inputs
Shortcablesrunsimprovethesoundqualityremarkably.Inputcablesshouldbeshortanddirect,
sincehighfrequencieswillmostlybeabsorbedifthecablesareunnecessarilylong.Besidesthata
longercablemayleadtohummingandnoiseproblems.Ifthecablerunsareunavoidable,youshould
usebalancedcables.
Outputs
Thehighdampingfactorofyourampliersuppliesaclearsoundreproduction.
Unnecessarilylongandthincableswillinuencethedampingfactorandthusthelowfrequencies
inanegativeway.Inordertosafeguardgoodsoundquality,thedampingfactorshouldliearound50.
Thelongeracablehastobethethickeritshouldbe.
ConnectyourspeakersystemsviathelockingspeakerconnectorsortheBannana/Screwcombination
(red+,black-)
Connection to the mains
Connecttheamplieronlyafterhavingmadesurethatthecorrectvoltage(240V)issuppliedandthat
thegroundcableisearthed.ThisproductfallsunderClass1.Donotdetachthegroundcable.
www.prolight.co.uk XTR Series Power Ampliers User Manual
7
Operating instructions
Operation
Afterhavingconnectedyourampliertothemains,turnbothgaincontrolscounterclockwisetothe
“min”position.Thelastproducttobeswitchedonisamplier.The“ON”and“PROTECT”LEDlightsup
now.Ifitdoesnot,checkiftheamplierisconnectedtothemainscorrectly.
Aftertheturnondelaythespeakersareactivated(PROTECT-LEDisoff).
Afterhavingsetthevolumecontrolsofthepre-ampliertothe“OFF”position,turnthegaincontrolsof
yourampliertomid-position.NowadjustthevolumewiththegaincontrolsCHAandCHB.
Allimportantoperatingmodesoftheamplierarearrangedonthefrontpanel.
Ifyouwanttoswitchoffthesystem,switch off the amplier rstinordertoavoid
acousticshocksonthespeakers.
Problem Chart
-20dBto30dB -Outputlevel
Clip -Shortcircuitorimpedancetooloworsignaldistorted
Protect -Activeduringstabilisationperiodafterswitchingonorwhenone
oftheprotectivecircuitsisactivated
Problem Cause Solution
Nopower Thepowercableisnotconnected Checkthepowercableandanyextensioncables
Nosound
Thepowercableoftherespectiveproductis
notconnectedcorrectlyornotatall.
Checkthepowercableandiftheplugsareproperly
connectedwiththesockets
Theconnectionsocketortheplugisdirty Cleanthesocketand/ortheplug
Noise Theinputsignalistoostrong Reducetheinputsignalviathegaincontrol
Fandoesnotwork,
LEDsdonotlightup
Thepowercableisnotconnected Connectthepowercable
ProtectLEDlights
uppermanently
DCvoltageoninput
Switchamplieroffandhavetheproductchecked
byaservicetechnician
Amplieroverheatsduetoobstruction Cleanthefangrill
Impedanceofspeakerstoolow Ensureminimum4Ωload
Shortcircuitinspeakerconnection
orinspeakers
Checkspeakersandconnections
CAUTION! - DANGER TO LIFE
DISCONNECT FROM THE MAINS BEFORE
STARTING MAINTENANCE OPERATION
www.prolight.co.uk XTR Series Power Ampliers User Manual
8
Operating instructions & WEEE notice
Cleaning and Maintenance
Werecommendafrequentcleaningoftheproduct.Pleaseuseasoftlintfreeandmoistenedcloth.
Neverusealcoholorsolvents.
Therearenoserviceablepartsinsidetheproductexceptforthefuse.Maintenanceandservice
operationsareonlytobecarriedoutbyauthoriseddealers.
Replacing the fuse
Onlyreplacethefusewithafuseofthesametypeandrating.
Beforereplacingthefuse,unplugthemainscable.
Procedure:
Step 1:Openfuseholderontherearpanelwithascrewdriver.
Step 2:Removetheoldfusefromthefuseholder.
Step 3:Installthenewfuseinthefuseholder.
Step 4:Replacethefuseholderinthehousing.
Shouldyouneedanyspareparts,pleaseusegenuineparts.
Shouldyouhaveanyfurtherquestions,pleasecontactyourdealer.
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
/