Wren HYPERION HYP-PP180R-B is a wireless perimeter detection unit designed to provide real-time monitoring and alerts for any unauthorized activity within its field of view. It features:

  • Wireless connectivity: Connects to a central gateway via a secure wireless link for easy deployment and scalability.
  • PIR motion detection: Detects movement using passive infrared sensors, providing accurate and reliable motion detection.
  • Built-in camera: Captures images or videos of detected motion, allowing for visual verification of events.
  • Customizable alerts: Sends real-time alerts via email, SMS, or push notifications to designated personnel.

Wren HYPERION HYP-PP180R-B is a wireless perimeter detection unit designed to provide real-time monitoring and alerts for any unauthorized activity within its field of view. It features:

  • Wireless connectivity: Connects to a central gateway via a secure wireless link for easy deployment and scalability.
  • PIR motion detection: Detects movement using passive infrared sensors, providing accurate and reliable motion detection.
  • Built-in camera: Captures images or videos of detected motion, allowing for visual verification of events.
  • Customizable alerts: Sends real-time alerts via email, SMS, or push notifications to designated personnel.
Hyperion Wireless PDU Installation Guide www.wrensolutions.com 7L778 Rev A 200428
INSTALLATION GUIDE
HYPERION PERIMETER DETECTION
HYP-PP180R-B
Hyperion Wireless PDU Installation Guide www.wrensolutions.com 7L778 Rev A 200428
ABOUT THIS DOCUMENT
This document pertains to installation of the Hyperion Perimeter
Detection Unit (HYP-PP180R-B). Before installation, please familiarize
yourself with this installation guide and review the Hyperion User
Guide to understand system configuration and setup.
PRODUCT MODIFICATIONS
This product is to be installed and used for the specific purpose for
which it was designed. It is not to be modified or serviced by anyone
other then Wren. Unauthorized changes or modifications to the
product will result in the warranty being voided and could possibly
invalidate regulatory certifications.
WARRANTY
Unless otherwise noted, all products are covered by Wren's Standard
Limited Manufacturer's Warranty as set forth in the current version of
Wren's Terms and Conditions
INTELLECTUAL PROPERTY RIGHTS
Wren maintains certain intellectual property rights that may pertain to
this product. To see a list of our patents, please refer to our
TRADEMARK ACKNOWLEDGMENTS
Wren®. the Wren logo, Hyperion® and the Hyperion logo are
trademarks of Wren. The trademarks that are followed by ® are
registered trademarks in the U.S. All other trademarks and/or
registered trademarks mentioned herein are properties of their
respective owners and are for reference purposes only. The use of
such third party trademarks does not indicate any affiliation with or
sponsorship of or by Wren. All rights reserved.
NOTICES
RF Exposure for FCC
WARNING: To satisfy FCC RF exposure requirements for mobile
transmitting devices, a separation distance of 31 cm or more should be
maintained between the antenna of this device and persons during
device operation. To ensure compliance, operations at closer than this
distance is not recommended. The antenna used for this transmitter
must not be co-located in conjunction with any other antenna or
transmitter.
RF Exposure for IC
WARNING: To satisfy IC RF exposure requirements for mobile
transmitting devices, a separation distance of 44 cm or more should be
maintained between the antenna of this device and persons during
device operation. To ensure compliance, operations at closer than this
distance is not recommended. The antenna used for this transmitter
must not be co-located in conjunction with any other antenna or
transmitter.
AVERTISSEMENT: Pour satisfaire IC RF exigences d’exposition pour
les appareils mobiles de transmission, une distance de séparation de 44
cm ou plus doit être maintenue entre l’antenne de cet appareil et des
personnes pendant le fonctionnement de l’appareil. Pour assurer la
conformité, les opérations au plus près que cette distance ne sont pas
recommandés. L’antenne utilisée pour cet émetteur ne doit pas être
situé en conjonction avec une autre antenne ou émetteur.
(800) 881-2249
PRODUCT SUPPORT
For comprehensive product support including manuals, FAQs and troubleshooting, visit our customer support portal.
WWW.WRENSOLUTIONS.COM
/HYPERION/HYPERION-SUPPORT
Hyperion Wireless PDU Installation Guide www.wrensolutions.com 7L778 Rev A 200428
Prior to installation, verify that all hardware is included. If there are missing components, please contact Wren.
COMPONENT LIST
REQUIRED TOOLS AND ACCESSORIES
#2 Phillips screwdriver
Drill
Cables (CAT5 or higher)
IDENTIFY DEVICE MOUNTING LOCATION
1
Mounting Surface
The PP180 should be mounted to a structurally solid, vertical wall surface. Mounting to a horizontal ceiling
surface is not recommended and will negatively impact device performance.
Mounting Height
Hyperion PDU
Power Supply
Hyperion Radio
w/ antenna
Hyperion Wireless PDU Installation Guide www.wrensolutions.com 7L778 Rev A 200428
IDENTIFY HYPERION RADIO MOUNTING LOCATION
2
Mounting Surface
The Hyperion Radio should be mounted indoors to a structurally solid surface. When selecting a mounting
location, take care to ensure that there are no obstructions, especially solid metal surfaces in the immediate
vicinity of the radio and antenna. We suggest a minimum 3 foot zone surrounding the area.
Mounting Height
The minimum recommended mounting height for the Hyperion Radio is 10 feet from ground level. Mounting
heights over or under 10 feet are acceptable but the areas must be free and clear of any obstructions.
NOTE:
OBSTRUCTIONS WILL NEGATIVELY IMPACT RADIO PERFORMANCE
ENSURE THAT THERE ARE NO OBSTRUCTIONS, ESPECIALLY METAL, NEAR THE HYPERION RADIO
OR ANTENNA
IT MAY BE NECESSARY TO RELOCATE THE RADIO IF PERFORMANCE /RECEPTION IS POOR.
Hyperion Wireless PDU Installation Guide www.wrensolutions.com 7L778 Rev A 200428
4
MOUNTING THE HYPERION RADIO
3
MOUNTING THE DEVICE
Expose the mounting bracket by removing
the 2 upper positioning screws and rotat-
ing the housing down.
Mount to the desired location using
#10 size fasteners and the appropriate
wall anchors (if required).
Re-install the upper positioning
screws. Position the device to the
appropriate angle identied in Step 1.
Mount to the desired location using #8
size fasteners and the appropriate wall
anchors (if required).
Attach the antenna to the radio and
position for maximum reception.
NOTE:
OBSTRUCTIONS WILL NEGATIVELY
IMPACT RADIO PERFORMANCE
ENSURE THAT THERE ARE NO
OBSTRUCTIONS, ESPECIALLY METAL,
NEAR THE HYPERION RADIO OR
ANTENNA
Hyperion Wireless PDU Installation Guide www.wrensolutions.com 7L778 Rev A 200428
6
RUN CABLING
Cabling Specications
Maximum cabling distance is 100 feet.
Cabling should be minimum CAT5 rated and at
least 24AWG.
Cabling Procedure
Run a length of CAT5 or greater cabling from
IHYP-PP180R-B to the Hyperion Radio.
Crimp RJ45 connectors to each end of the ca-
ble run if needed.
Certify that the cabling meets the T-568A
standard.
5
WALL PENETRATION PREP
Drill an appropriate sized wall penetration
to pass a CAT5 ethernet cable from the
device to the radio.
Hyperion Wireless PDU Installation Guide www.wrensolutions.com 7L778 Rev A 200428
NOTE:
THESE ARE NOT ETHERNET PORTS
ENSURE THAT ALL CABLING CONNECTIONS HAVE BEEN CERTIFIED BEFORE ATTACHING TO ANY
DEVICES
7
CONNECTING DEVICES
9
CONNECT POWER
Use the provided power supply to apply power the
radio.
8
CONNECT DEVICE DATA
Connect the CAT5 cabling to the device and to the
radio
10
ADD DEVICE TO THE GATEWAY
The device is now powered on and ready to be added to Hyperion.
Refer to the Hyperion User Manual for setup details.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Wren HYPERION HYP-PP180R-B Installation guide

Type
Installation guide

Wren HYPERION HYP-PP180R-B is a wireless perimeter detection unit designed to provide real-time monitoring and alerts for any unauthorized activity within its field of view. It features:

  • Wireless connectivity: Connects to a central gateway via a secure wireless link for easy deployment and scalability.
  • PIR motion detection: Detects movement using passive infrared sensors, providing accurate and reliable motion detection.
  • Built-in camera: Captures images or videos of detected motion, allowing for visual verification of events.
  • Customizable alerts: Sends real-time alerts via email, SMS, or push notifications to designated personnel.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages