  • Hello! I am an AI chatbot trained to assist you with the Danfoss KE04112 Valve Drive Amplifier Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Unit Specification
3500 Annapolis Lane North, Minneapolis, MN 55447
Telephone: (763) 509-2084 Telefax: (763) 559-0108 ISSUE: 2 DATE: September 1996
KE04112
Valve Drive Amplifier
GENERAL DESCRIPTION
DIMENSIONS
OUTPUT CHARACTERISTICS
CONNECTION DIAGRAM
.
.
1901
1651A
The device is a free-standing amplifier mounted on 4 stand offs. Current or voltage signal from a transducer/controller, through
the amplifier, produces current to drive electrohydraulic actuators. Connections to the amplifier are via screw terminals.
SUPPLY VOLTAGE
48 Vdc
INPUT IMPEDANCE
240 ohm
START CURRENT
4 mA nominal (1 Volt)
FULL STROKE CURRENT
20 mA (4.8 Volt)
OUTPUT CURRENT
100 mA into a 25 ohm load
12,70
(0.50)
9,65
(0.38)
5,33 (0.21) INSIDE DIA.
76,20
(3.00)
57,15
(2.25)
6,35
(0.25)
114,30 (4.50)
101,60 (4.00)
Dimensions of the KE04112 in Millimeters (Inches).
1902
1
2
3
4
5
6
7
8
9
10
VALVE COILDIRECT OUTPUT
48 Vdc
SIGNAL COMMON
4 TO 20 mA SIGNAL
TRANSDUCER/
CONTROLLER
EDC
AB
1
2
2
1 INPUT IMPEDANCE IS 240 OHMS
DIRECT OUTPUT: 200 mA AT 10 VOLTS MAXIMUM
CURRENT
SOURCE
KEO4112
VALVE
DRIVE
AMPLIFIER
10
20
30
40
50
60
70
80
90
100
% MAXIMUM
OUTPUT VOLTAGE
% SUPPLY VOLTAGE
0 2 4 6 8 10 12 14 16 18 20
© Danfoss, 2013-09 K19479 UNIT SPEC 1
/