Intratone EEN-M3G Owner's manual

Type
Owner's manual
Connection and fitting guid 3G module (EEN-M3G) Intratone
Page 1 / 4 EN-V231 – 0104 – AB
Installation and cabling of the 3G Module
This 3G module (ref: EEN-M3G) enables audio and video communications.
Audio Panel + 3G Module Audio call
Visio Panel + 3G Module Audio and Visio call
When you do not have any 3G network on site, the 3G Module will search the GSM network
automatically and will resume to theses functionalities:
- Audio call (without Visio)
- Update in real time on the GSM network.
It does exist an external aerial to hide the 3G Module in a technical room and install the aerial
outdoor.
Connectors are now dedicated to the electronic notice board (Auxiliary Data Bus).
The LEDs show the quality of the network on site:
«The more LEDs are on, the better is the reception ».
Operational level will be optimal from 3 LEDs on.
A low level of reception may result in impossibility to make calls
or updates. We therefore advise you to carry out several tests in
order to find the location that provides the best level of reception
.
The 3G Module
can be moved up to 100m
; an aerial can be
installed if necessary.
The 3G Module can be fitted both outdoor and indoor.
N
EVER FIT THE MODULE INSIDE A METAL CASE
!
Connection and fitting guid 3G module (EEN-M3G) Intratone
Page 2 / 4 EN-V231 – 0104 – AB
Description of the 3G Module
Meaning of the LEDs
Behaviour
Explanation
Note :
If the 3G network is available then LEDs are ON permanently.
If the 3G network is not available then the network downgrade to GSM. In the case only
the LEds behave has indicated in the section

.
If the 3G module is tune to the GSM network, it will try to reconnect itself to the 3G
network frequently.

Led ON from 1 to 5 Test LEDs functionality

LED No flash Search the network

4 first LEDs ON In this example reception level : 4 / 5

The 3 middle LEDs are ON from
time to time.
Indicate the only the GSM network has
been found
Installation direction to respect necessarily
Be careful
to respect the connections V+ and V- for
each Video connector.
Video 1: Cable this connector on the connectors V+
and V- of a Visio Panel.
Video 2: Permit to:
Cable another Visio Panel (V+ and V).
Plug a secondary camera, please contact our
technical support.
Connector external aerial: change switch position
To use an external antenna, switch the switch
down (1 position).
Without aerial, leave the switch ON (like
manufactory setting).
Switch: To use an aerial (see below)
Auxiliary Data Bus
:
dedicated to « EFR-TAF »
WARNING: always use the
connectors to connect an electronic
noticeboard (EEN-TAF-15-0).
See installation
guide for
E
EN
-
TAF
-
-
0
Connection and fitting guid 3G module (EEN-M3G) Intratone
Page 3 / 4 EN-V231 – 0104 – AB
Connection of the 3G module to a central EEN-CEN-12 :
Connection of the 3G module to a central EEN-CIC-12 :
O
N TERMINAL BLOCKS
11
TO
16
OF THE
R
ESIDENTIAL
C
ENTRAL
U
NIT
Always connect 3G module to these terminal blocks
Never connect a panel nor display board to these
terminal blocks.
ENN-CEN-12
To panels or
other
peripherals
CENTRAL UNIT
EEN-CIC-12
-
D+
D-
+
See central
unit guide
12/24
V
DC
-
2
A
MP
(NOT INCLUDED)
As close as possible
from central unit
D+
D-
A
+
-
+
A-
+
-
1
2
3
4
5
6
7
8
9
11
13
14
15
16
17
18
19
C
R
T
12
1
2
3
4
5
6
7
8
9
21
23
24
25
26
27
28
29
C
R
T
22
Connector 1 of the central unit
11 to 19 and CRT
Connector 2 of the central unit
21 to 29 and CRT
12/24
V
DC
-
2
A
MP
(NOT INCLUDED)
As close as possible
from central unit
See central
unit guide
To panels or other
peripherals
-
D+
D-
+
A+
A-
Twisted cables
Max 100m from power supply
Ø 0.8
Twisted cables
Max 100m from power supply
Ø 0.8
Connection and fitting guid 3G module (EEN-M3G) Intratone
Page 4 / 4 EN-V231 – 0104 – AB
Norms :
EC standards:
- The 3G module complies with the R&TTE Directive 1999/5/EC: electrical safety
standard EN 60950(2001) applied, EMC standard EN 301 489-3 (2002) applied, radio
standard EN 300 330-2 (2001) applied.
- The 3G module complies standards
o 3GPP 51.010-1 : 3G
o EN 301 511 : GSM (Radio spectrum)
- The 3G module complies with EMC standards EN 301 489-1 and EN 301 489-7.
Cabling:
- -The cables connected to the central unit must not be placed in the vicinity of other
sources of electrical power (e.g. mains power supply).
- 3-pairs twisted cable using min 0.80 mm diameter wire.
Operating warranty
- The 3G module is guaranteed to operate within a temperature range of between -20°C
and +70°C and for relative humidity that does not exceed 70%.
- The 3G module must be installed as indicated TOP / BOTTOM in the guide.
End of life product recycling:
-
The 3G module and its accessories must not be disposed of with unsorted municipal waste, but
must follow the WEEE (Waste Electrical and Electronic Equipment) collection and recycling
Sizes:
TOP
BOTTOM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Intratone EEN-M3G Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI