Ada BC-232 Operating instructions

Type
Operating instructions
ADA Bus™/RS-232 TRANSLATOR
BC-232
RS-232
GND=1 2 3 4=+15V
TX RX
ADA Bus
5 4 3 2 1
9 8 7 6
The BC-232
The BC-232 (BUS CONVERTER) is a standard level converter for DCE to DTE in any
media for communication via an RS-232-C (IEEE Standard). Whether this media incorpo-
rates a computer or a simpler device of communication it must have an RS-232 socket for
proper function. Violating this standard may cause a hazardous situation, resulting in dam-
aged property and a non-refundable product.
The BC-232 must have +15VDC & GND on ADABUS side to operate.
Please note: Settings for any communicating device are 8 Bits, 1200 Baud, 1 Start bit, 1
Stop bit, No Parity for all ADA Products. Unless otherwise specified.
RX TX
These 3 Pins;
1. PIN 2(TX) - Used for Transmitting to the ADABUS via
the BC-232.
2. PIN 3(RX) - Used for Receiving from the ADABUS via
the BC-232.
3. PIN 6(GND) - Ground.
Are the only pins that will be used for any application.
LOOPing is a method of testing the port. Pins 45, 78 are internally tied together within
the BC-232.
The other pins (CTS, DTR, and RTS) are not used at all.
PIN 1(NO CONNECTION)
PIN 2(TX)
PIN 3(RX)
PIN 4(LOOP A)
PIN 5(LOOP A)
PIN 6(GND)
PIN 7(LOOP B)
PIN 8(LOOP B)
PIN 9(NO CONNECTION)
GND
  • Page 1 1

Ada BC-232 Operating instructions

Type