Page 9 - FA01534-EN - 02/2022 - © CAME S.p.A.
Activation
Press and hold the 1 button for at least 25 seconds, until the LED 2 fl ashes quickly.
Put the jumper 3 in the [+] position.
On the internal receiver, press the intercommunicating button you wish to use to call it.
You will hear a beep to signal that the internal receiver has been added to the
intercommunicating group.
You can change the internal receiver call button by repeating the activation
procedure.
Press the button 1 to end the procedure and position the jumper 3 in neutral.
Repeat the procedure for each internal receiver you want to add to the
intercommunicating group.
You can add up to 4 internal receivers per intercommunicating group.
The procedure ends automatically after 30 minutes of inactivity.
After adding an internal receiver to an intercommunicating group, it can no longer
be excluded from that group.
Deactivation
Press and hold the 1 button for at least 25 seconds, until the LED 2 fl ashes quickly.
Put the jumper 3 in the [-] position.
Keep the jumper in this position for at least 20 seconds.
Press the button 1 to end the procedure and position the jumper 3 in neutral.