Honeywell TH1100DV User manual

  • Hello! I am an AI chatbot trained to assist you with the Honeywell TH1100DV User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
® U.S. Registered Trademark. Patents pending.
Copyright © 2013 Honeywell International Inc.
All rights reserved.
Installation
Guide
PRO TH2000DV/TH1000DV Series
Thermostats
This manual covers the following models
• TH1100DV:ForHeatonlysystems
• TH2110DV/TH1110DV:For1Heat/1Coolsystems
• TH2210DV/TH1210DV:For2Heat/1Coolheatpumpsystemsonly
(Pullthermostatfromwallplateandturnovertofindmodelnumber.)
System Types
TH2110DV/TH1110DV:
• Gas,oil,orelectricheatwithair
conditioning
• Warmair,hotwater,high-efficiency
furnaces,1Heat/1Coolheatpumps,
steam,gravity
• Heatonly
• Heatonlywithfan
• Coolonly
• 750mVheatingsystems
TH2210DV/TH1210DV:
• 2Heat/1Coolheatpumps
TH1100DV:
• Gas,oil,orelectricheat
• Warmair,hotwater,steam,gravity
• Heatonly
• 750mVheatingsystems
Must be installed by a trained, experienced technician
Readtheseinstructionscarefully.Failuretofollowtheseinstructions
candamagetheproductorcauseahazardouscondition.
Need Help?
Forassistancewiththisproductpleasevisithttp://customer.honeywell.com
orcallHoneywellCustomerCaretoll-freeat1-800-468-1502
69-2800EFS-01
Installation Guide
2
69-2800EFS—01
C IS OPTIONAL
WITH BATTERIES
NOT
USED
R
C
AUX/
E
Y
G
O
B
M34682
Wallplateinstallation
Removethewallplatefromthethermostat
asshownatleft,thenfollowdirections
belowformounting.
1. Pullwiresthroughwirehole.
2. Positionwallplateonwall,levelandmarkhole
positions with pencil.
3. Drillholesatmarkedpositionsasshownbelow,
thentapinsuppliedwallanchors.
4. Placewallplateoveranchors,insertandtighten
mountingscrews.
Pullatbottomtoremovethermostatfrom
wallplate.
CAUTION: ELECTRICAL HAZARD
Cancauseelectricalshockorequipmentdamage.Disconnectpowerbeforebeginning
installation.
Drill3/16"holesfordrywall.Drill7/32"holesforplaster.
MERCURY NOTICE
Ifthisproductisreplacingacontrolthatcontainsmercuryinasealedtube,donotplace
the old control in the trash. Contact the Thermostat Recycling Corporation at
www.thermostat-recycle.orgor800-238-8192forinformationonhowandwheretoproperly
andsafelydisposeofyouroldthermostat.
M34683
Wallanchors
Mountingscrews
Wirehole
PRO TH2000DV/TH1000DV Series
3
69-2800EFS—01
Power options
TH2110DV/TH1110DV:
B Changeovervalveenergizedinheating
O Changeovervalveenergizedincooling
G Fanrelay
Y Compressor contactor
W Heat relay
C 24Vaccommon.For2-transformer
systems,usecommonwirefrom
coolingtransformer.
R 24Vacpowerfromheatingtransformer
Rc 24Vacpowerfromcoolingtransformer
TH2210DV/TH1210DV:
B Changeovervalveenergizedin
heating
O Changeovervalveenergizedin
cooling
G Fanrelay
Y Compressor contactor
Aux/E Auxiliaryheatrelay
C 24Vaccommon
R 24Vacpower
TH1100DV:
W Heat relay
C 24Vaccommon
R 24Vacpower
Terminal designations
Wiring
M32808B
RWYG
B
RcO C
TH2110DV/
TH1110DV
CYGO
BR
Aux/
E
M32809B
TH2210DV/TH1210DV
Not
Used
M34673
INSERT BATTERIES FOR
PRIMARY OR BACKUP POWER
M34699
KEEP WIRES IN
THIS SHADED AREA
REMOVE FACTORY-INSTALLED JUMPER
ONLY FOR TWO-TRANSFORMER SYSTEMS
CONNECT C FOR PRIMARY
AC POWER (OPTIONAL IF
BATTERIES ARE INSTALLED)
RC
R
C
W
Y
G
O
B
TERMINAL
BLOCK SHOWN
M34800
RW C
TH1100DH
Installation Guide
4
69-2800EFS—01
Wiring
2H/1C Heat
Pump System
TH2210DV/TH1210DV
B Changeovervalveenergizedin
heating[5]
O Changeovervalveenergizedin
cooling[5]
G Fanrelay
Y Compressor contactor
Aux/E Auxiliaryheatrelay
C 24Vaccommon[3]
R Power[1]
1H/1C System
TH2110DV/
TH1110DV
(1 transformer)
G Fanrelay
Y Compressor contactor
W Heat relay
C 24Vaccommon[3]
R [R+Rcjoinedbyjumper]
Rc Power[1]
1H/1C System
TH2110DV/
TH1110DV
(2 transformers)
G Fanrelay
Y Compressor contactor
W Heat relay
C 24Vaccommon[3,4]
R Power(heatingtransformer)[1,2]
Rc Power(coolingtransformer)[1,2]
Heat Only System
TH1100DV
W Heat relay
C 24Vaccommon[3]
R Power[1]
1H/1C Heat
Pump System
TH2110DV/TH1110DV [7]
B Changeovervalveenergizedin
heating[5]
O Changeovervalveenergizedin
cooling[5]
G Fanrelay
Y Compressorcontactor[6]
W [W+Yjoinedbyjumper]
C 24Vaccommon[3]
R [R+Rcjoinedbyjumper]
Rc Power[1]
Heat Only
System
TH2110DV/TH1110DV
W Heat relay
C 24Vaccommon[3]
R [R+Rcjoinedbyjumper]
Rc Power[1]
Heat Only
System with
Fan TH2110DV/TH1110DV
G Fanrelay
W Heat relay
C 24Vaccommon[3]
R [R+Rcjoinedbyjumper]
Rc Power[1]
Cool Only
System
TH2110DV/TH1110DV
G Fanrelay
Y Compressor contactor
C 24Vaccommon[3]
R [R+Rcjoinedbyjumper]
Rc Power[1]
NOTES
Wirespecifications:
Use18-to22-gaugethermostatwire.
Shieldedcableisnotrequired.
[1] Powersupply.Providedisconnectmeansand
overloadprotectionasrequired.
[2] Removejumperfor2-transformersystems.
[3] Optional24Vaccommonconnection.
[4] Commonconnectionmustcomefromcool-
ingtransformer.
[5] UseeitherOorBterminalsforchangeover
valve.
[6] Useasmallpieceofwire(notsupplied)to
connectWandYterminals.
[7] SetfanoperationswitchtoHeat Pump
(seepage5).
Wiring guide — conventional and heat pump systems
CYGO
BR
Aux/
E
M32809B
TH2210DV/TH1210DV
Not
Used
RcCYW
GR
M32811
RcCYW
GR
M32812
RcCYWGO
BR
M32813
RcC
WR
M32814
RcCW
GR
M32815
RcCY
GR
M32816
See[notes]below
M34801
RW C
PRO TH2000DV/TH1000DV Series
5
69-2800EFS—01
M34679
Set
Cool
77
On
Fan
Auto
On
C IS OPTIONAL
WITH BATTERIES
NOT
USED
R
C
AUX/
E
Y
G
O
B
Fan
Auto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34676
Set
Cool
77
On
Fan
Auto
On
Off
Cool
Heat
C IS OPTIONAL
WITH BATTERIES
RC
R
C
W
Y
G
O
B
TH2110DV/TH1110DV only:
• Gas or Oil:Forgasoroilheating
systems,leavethefanoperation
switchinthisfactory-setposition.
(Thissettingisforsystemsthat
controlthefaninacallforheat.)
• Electric or Heat Pump:Change
theswitchtothissettingforheat
pumporelectricheatsystems.
(Thissettingisforsystemsthat
allow the thermostat to control the
faninacallforheat,ifafanwire
is connected to the Gterminal.)
Alignthethermostatwiththetabsonthe
wallplate,thenpushgentlyuntilthether-
mostat snaps in place.
Thermostatmounting
Setfanoperationswitch.
Pushexcesswire
backintothewall
opening.
Plugwallopening
withnon-flammable
insulation.
Fanoperationsettings
M34674
ELECTRIC
OR HEAT PUMP
GAS OR OIL
ELECTRIC
OR HEAT PUMP
GAS OR OIL
Installation Guide
6
69-2800EFS—01
5
5
M32819
Followtheprocedurebelowtoconfigurethethermostattomatchtheinstalled
heating/coolingsystem,andcustomizefeatureoperationasdesired.
Function
number
Setting
Tobegin,press and hold the s and tbuttonsuntilthedisplaychanges.
Press the s or tbuttontochangethesetting.
Press the s and tbuttonssimultaneouslyforonesecondto
advancetothenextfunction.
Press and hold the s and tbuttonstoexitandsavesettings.
Installersetup
M34680
Fan
Auto
On
Off
Cool
Heat
Set
Hold
Run
E.M. Heat
M34681
Set
Cool
77
On
Fan
Auto
On
Off
Cool
Heat
NOTE:Ifyoudonotpressanybuttonfor60secondswhileyouareinthe
setupmenu,thethermostatautomaticallysavesanychangesmadeand
exitsthemenu.
PRO TH2000DV/TH1000DV Series
7
69-2800EFS—01
Setup function Settings & options (factory default in bold)
5 Heating cycle rate
(CPH: cycles/hour)
TH2110DV, TH1110DV and
TH1100DV
5 For gas or oil furnaces of less than 90% efficiency
1 Forsteamorgravitysystems
3 Forhotwatersystems&furnacesofover90%efficiency
6 Forelectricfurnaces
[Othercyclerateoptions:2or4CPH]
6 Auxiliary heat
cycle rate (CPH)
TH2210DV and TH1210DV
3 For hot water systems & furnaces of over 90%
efficiency
1 Forsteamorgravitysystems
5 Forgasoroilfurnacesoflessthan90%efficiency
6 Forelectricfurnaces
[Othercyclerateoptions:2or4CPH]
9 Compressor
cycle rate (CPH)
3 Recommended for most compressors
[Othercyclerateoptions:1,2,4,5,or6CPH]
13 Early Start (TH2110DV
and TH2210DV)
1 On **See page 8
0 Off
14 Temperature
display
0 Fahrenheit
1 Celsius
15 Compressor
protection
1 Five-minute compressor off time (See page 8)
0 Nocompressorofftime
20 Clock display (TH2110DV
and TH2210DV)
0 12-hour display
1 24-hourdisplay
25 Lower temperature
range (TH1100DV only)
0 Standard range 40°F to 90°F (4.5°C to 32°C)
1 Lowerrange(forgaragemode)35°Fto90°F
(1.5°Cto32°C)
40 Restore program
schedule to default
(TH2110DV and
TH2210DV)
0 Off
1 On-programscheduledefaultsettingsarelistedinthe
operatingmanual
Installersetup
CAUTION: EQUIPMENT DAMAGE HAZARD
Compressorprotectionisbypassedduringtesting.Topreventequipmentdamage,avoid
cyclingthecompressorquickly.
NOTE: Theoptionsbelowmaynotbeavailableinallmodels.
Installation Guide
Automation and Control Solutions
Honeywell International Inc.
1985DouglasDriveNorth
GoldenValley,MN55422
http://customer.honeywell.com
® U.S. Registered Trademark
© 2013 Honeywell International Inc.
69-2800EFS—01M.S.05-13
Printed in U.S.A.
Early Start (SetupFunction13):Earlystartallowstheheatingorcoolingtoturnonbeforethe
programstarttime,sothetemperatureisreachedatthetimeyouset.
Compressor Protection(SetupFunction15):Forcesthecompressortowaitafewminutesbefore
restarting,topreventdamage.Duringthewaittime,themessageCoolOnorHeatOn(heatpumps
only)willflashonthedisplay.
Please contact your distributor to order replacement parts.
Cover plate assembly* ........................................ PartNumber50002883-001
*Usetocovermarksleftbyoldthermostats.
Temperature Ranges
• Heat:40°to90°F(4.5°to32°C)
• Cool:50°to99°F(10°to37°C)
Operating Ambient Temperature
• 32°to120°F(0°to48.9°C)
Shipping Temperature
• -20°to120°F(-28.9°to48.9°C)
Operating Relative Humidity
• 5%to90%(non-condensing)
Physical Dimensions
• 3-7/16”Hx4-10/16”Wx1-3/16”D
87mmHx119mmWx30mmD
Electrical Ratings
System Voltage(50/60Hz) RunningCurrent
Heat(1ststage) 20-30Vac 0.02-1.0A
(Powerpile) 750mVDC 100mADC
Auxiliaryheat 20-30Vac 0.02-1.0A
Cooling 20-30Vac 0.02-1.0A
Accessories&replacementparts
Specialfunctions
Specifications
3
69-2800EFS—01
Série PRO TH2000DV/TH1000DV
Optionsd’alimentation
TH2110DV/TH1110DV :
B Vanned’inversiondéclenchéeenmode
dechauffage
O Vanned’inversiondéclenchéeenmode
derefroidissement
G Relaisdeventilateur
Y Contacteurducompresseur
W Relaisdechauffage
C Commun24Vc.a.Danslessystèmes
àdeuxtransformateurs,utiliserle
filcommundutransformateurde
refroidissement.
R Alimentation24Vc.a.provenantdu
transformateurdechauffage
Rc Alimentation24Vc.a.provenantdu
transformateurderefroidissement
TH2210DV/TH1210DV :
B Vanned’inversiondéclenchéeen
modedechauffage
O Vanned’inversiondéclenchéeen
modederefroidissement
G Relaisdeventilateur
Y Contacteurducompresseur
Aux/E Relaisdesystèmedechauffage
auxiliaire
C Commun24Vc.a.
R Alimentation24Vc.a.
Désignation des bornes
Câblage
M32808B
RWYG
B
RcO C
TH2110DV/
TH1110DV
CYGO
BR
Aux/
E
M32809B
TH2210DV/TH1210DV
Non
utilisée
TH1100DV :
W Relaisdechauffage
C Commun24Vc.a.
R Alimentation24Vc.a.
MF34673
INSÉRER LES PILES POUR L’ALIMENTATION
PRIMAIRE OU DE SECOURS.
MF34699
GARDER LES FILS DANS
CETTE ZONE OMBRAGÉE
SEULEMENT SI LE SYSTÈME EST À DEUX
TRANSFORMATEURS
RACCORDER LA BORNE C
POUR L’ALIMENTATION
PRINCIPALE EN C.A. (OPTIONNEL
SI DES PILES SONT INSTALLÉES).
BORNIER
RC
R
C
W
Y
G
O
B
M34800
RW C
TH1100DH
/