4. Operation Displays and Error Messages
Display Explanation Comments
P?
743A01
---REF--->
REF--->
---x---
POS-ERR
--( )--
SW?
E2
STOP
b417
b16
b4
Illegal program
Display of the program version
Run to reference point
Run to reference point
Thread breakage
Motor not turning
No signal from the position transmitter
invalid revolution level set
Fuse E2 on the control transformer defective
Stop button defective
Glide plate not locked in
invalid switch position from b417
Form assembly not present
Sewing released
Set
" Programm "
switch anew
-
-
-
Reinsert thread
Check motor protection switch
Check position transmitter
Set
" Programm "
switch anew
Replace fuse
Replace stop button
Lock-in glide plate
Set b417 switch anew
Insert form assembly
-
SMC-TEST
AMP ERR
LINK OK
LINK ERR
EPROM OK
EPROM ERR
XCOU OK
XCOU ERR
SCOU OK
SCOU ERR
Step motor controller is being tested
Fault in the power output
Transmission cable not plugged in
Transmission to controller OK
Error in data transfer
EPROM OK
EPROM defective
Counter component for pulse counting OK
Counter comp. for pulse counting defective
Counter component for pulse generation OK
Counter comp. for pulse generation defective
-
Call factory service dept.
Plug in transmission cable
-
Call factory service dept.
-
Install new EPROM
-
Call factory service dept.
-
Call factory service dept.
ERROR 0
ERROR 1
ERROR 2
ERROR 3
ERROR 4
ERROR 5
ERROR 6
ERROR 7
ERROR B5
ERROR B45
Error Bxx
RAM-error
Fault in the input elements
Fault in the front panel elements
Program switch defective
Error in data transfer to sewing drive
controller
Short voltage drops in the mains
Timer 1 defective
Timer 2 defective
Transport carriage left (end position)
Light barrier (no sewing material present)
Fault in input element Bxx
Call factory service dept.
Check input elements
Check front panel elements
Replace program switch
Call factory service dept.
Stabilize voltage supply
Call factory service dept.
Call factory service dept.
Manually push into the initial position
Insert sewing material
Bxx defective or mis-adjusted
PROG
ERROR 1
PROG
ERROR 2
Error in the values in the memory
Error in putting the check sum into memory
Reset seam lengths, blower times, etc.
Program not properly stored in memory
12