CAME PSA Installation guide

Type
Installation guide

CAME PSA is a multitasking device combining functions of a ticket printer, TAG RFID proximity card reader and a color monitor with touch screen for improved user interaction. Additionally, it features payment terminals for coins and notes, ATM and credit cards for maximum user convenience. The device provides change in coins and optionally in notes, and is also equipped with barcode and QR code reader for added functionality.

CAME PSA is a multitasking device combining functions of a ticket printer, TAG RFID proximity card reader and a color monitor with touch screen for improved user interaction. Additionally, it features payment terminals for coins and notes, ATM and credit cards for maximum user convenience. The device provides change in coins and optionally in notes, and is also equipped with barcode and QR code reader for added functionality.

AUTOMATIC CASHIER
001PSA-K022C02
001PSA-K022C07
001PSA-K023C03
INSTALLATION MANUAL
EN
English
FA01290-EN
p. 2 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
SUMMARY
1. Description ................................................................................................................................................ 4
2. Technical specifications ............................................................................................................................ 5
3. Dimensions (mm) ...................................................................................................................................... 8
4. Automatic pay station card - description .................................................................................................14
5. Automatic pay station card - installation .................................................................................................18
6. Manned pay station - installation............................................................................................................ 31
1 Description
001PSA-K022C02 - Automatic Cashier with Lockable, Removable 500 notes cashbox
001PSA-K022C07 - Automatic Cashier with Lockable, Removable 1000 notes cashbox
001PSA-K023C03
Automatic pay station Unit for automatic payment that involves the following main functions:
- Reading and printing of tickets
- TAG RFID proximity card reading
- TFT 15.4 ’ colour monitor also available in high brightness and touch
versions.
- payment receipt
- payment in coins and notes, with ATM card and credit card (optional)
- change in coins (also available with note change option)
- barcode and QR-code reader also from smartphones
2 Technical specifications
The specified characteristics are indicative. They may be changed without prior notice.
Automatic pay station
Power supply
230 V AC 50/60 Hz 3,5 A max - 120 V AC 50/60 Hz 5 A max
230 V AC 50/60 Hz 13 A max - 120 V AC 50/60 Hz 20 A max
(With optional additional heater 001PSAC142)
Absorption at rest (stand-by) 70 VA
Protection rating IP33
Weight 225 kg
Operating temperature -5°C ÷ + 55°C
-40°C ÷ + 55°C (with optional additional heater
001PSAC142)
Storage temperature 0 °C ÷ + 70 °C
p. 3 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
3 Overall dimensions (mm)
Please note that the units must be fixed on a base 120 at a minimum depth of 600.
530 750
295
750
295
157,75 157,75
460
1716,5
ø 14
50 mm
≥100 mm
мм
Automatic pay station
The automatic pay station must be installed in a sheltered area protected from rain, snow, dust, or other elements.
If necessary, install elements such as canopies and side panels to protect the pay station against atmospheric and environmental
agents.
The automatic pay station has been dimensioned taking into account an underlying base of about 50 mm high.
7
8
14
14
11
1 2 3 4 5 6
10
91213
16
15
17
p. 4 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
4 Automatic pay station card - description
1. VAC power supply input
2. Interior lighting connection terminal
3. Fan and heater connection terminal
4. Remote alarm output terminal
5. Reset relay terminal
6. Power supply detector terminal
7. Paper sensor photocell
8. Pay station top element LED strip connection
9. Data connection
10. Input status indicator LED
11. Operating LED
12. Input connection terminals
13. Vdc power supply inputs
14. Seismic sensor connection
15. Fan and heater fuses F2=3.15A-T
16. Interior lighting fuse F1=1A-T
17. Internal siren connection
+ -
p. 5 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
INPUT CONDITION OF LED ON: N.B.
IN1 Upper door closed (maintenance compartment)
IN2 Middle door closed (cash compartment)
IN3 Collection Drawer Fitted
IN4 Coins Drawer Fitted
IN5 Coins Drawer Engaged
IN6 Vac power present
LED index input on automatic pay station card
USB camera
connection
Reader-Printer RS232
connection
Ethernet Network
Connection
Connection
LCD Monitor LVDS
Reserved
Ethernet Connection
RS485 connection
I/O boards
2D Reader USB
connection
USB optionals
connection Power supply
input
USB audio interface connection
Automatic Pay Station CPU connections
6
78910
16 17 18 191514
4
13
12
11
3
2
1
5
p. 6 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
CCTALK card
Compact
Flash Memory Slot
CCTALK interface
RS232 connection
Receipt Printer RS232
connection
1. Activation key for card self-diagnostics TEST
2. Reserved
3. Reserved
4. CCTALK 6 Channel - connection available
5. CCTALK address selection Dipswitch
6. CCTALK 5 Channel - change return Hopper 1 connection
7. CCTALK 3 Channel - connection available
8. CCTALK 2 Channel - change return Hopper 2 connection
9. CCTALK 1 Channel - change return Hopper 3 connection
10. Power supply input
11. Voltage selection on CN6 and CN8
12. CCTALK 5 Channel - change load Hopper connection
13. RS232 from Computer
14. Reject device connection
15. Change and Receipts drawer LED connection
16. Reserved
17. Reserved
18. CCTALK 6 Channel - Coin reader connection
19. CCTALK 4 Channel - Note reader connection
LED STATUS DESCRIPTION
Green LED RUN (flashing ON)
Red LED ERROR (normally OFF)
Blue LED CCTALK RX line (normally OFF)
Yellow
LEDs: CCTALK CHx line (normally OFF)
1
8
9
10
2
16
18
17
3
13
14
41112
5
6
15
7
p. 7 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
Automatic Pay Station Connections Board
1. Coin slot shutter
2. LCD Backlight
3. User keys
4. Ticket slit LED
5. Rfid Reader
6. Brightness sensor
7. Power supply and data input
8. Loud speaker
9. Audio input
10. Microphone
11. Coin slit LED
12. Reserved
13. Reserved
14. Accessories power supply
15. Jumper open
16. Reserved
17. Reserved
18. Reserved
p. 8 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
5 Automatic pay station - installation
Wear protective gloves when installing the system.
Enclose the work area and implement all
the requirements on the safe use of moving
mechanical equipment. Risk of swinging
parts
- Apply three steel cables with hooks at the end with a capacity
of at least 250 kg, in the seats on the head of the central element.
- Use a mechanical arm to tension the steel cables and then lift
the central element and bring it above the base.
- Insert the gasket between the two elements then slowly lower
the central element while making sure to centre the holes on the
base until it is supported upright.
- Release the harness.
- Fit and tighten the 10 fixing screws (supplied) of the base to the
central element.
The automatic pay station is supplied in
three elements that require assembly:
- base plate
- central element
- top element
Base
Top element
Central element
Automatic pay station installation
gasket
p. 9 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
- Position the top element above the central one, and then secure the nine
screws supplied.
-Connect the LED connector to the top element on the left
side of the pay station.
- Remove the screw that secures the
printer.
p. 10 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
Power supply and ETHERNET connection
- Ground the cabinet by connecting it to the site ground
connector using cables of at least 4 mm².
- Connect the ground points between the two parts that
make up the cabinet with the supplied cable.
Power from the main electrical panel of the site to provide adequate all-pole disconnect device for
disconnecting line voltage (MCB + RCD). Required characteristics:
Circuit breaker with breaking current up to 16 A (230 V) or 25 A (120 V);
RCD with 30 mA sensitivity.
Before connecting the device, disable the external all-pole disconnecting device.
The minimum cross section of the double insulated cable must be based on the characteristics and size of the plant, and in any
event not less than 2.5 mm².
Connect the ground cable to the top element.
L
N
p. 11 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
- Plug the power cables in the correct locations of the socket.
- Fix the shell on the socket by tightening the respective fixing
screws.
- Inside the top compartment on the left side, connect the
Ethernet cable to its terminal.
- Inside the upper compartment on the left side, connect the
power cord from the base to its terminal.
S1
S2
100 VA
p. 12 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
- Place the UPS on the bottom shelf.
- Use the supplied cable for the connections.
- The picture opposite shows the final layout
- After making the connections, switch on the automatic pay
station lifting first the external all-pole disconnecting device.
and then the two switches in the electrical panel located in the
upper part of the cabinet.
Switching on
V AC service outlet: 100 VA maximum load, protected by S1
(230V version only)
SWITCH DESCRIPTION
S1 Input circuit breaker
S2 UPS circuit breaker
- A UPS connection is located inside the top RH compartment
of the cabinet. It can be installed for backup power during
disruptions.
- Unplug the power cable indicated above.
Installing the UPS (not supplied)
The uninterruptible power supply (UPS) must be suited to the characteristics of the electricity grid and to the environmental
characteristics related to the installation site.
UPS REQUIRED CHARACTERISTICS
Output power 500 W / 750 VA
Type of wave Sine wave
Output connection type IEC 320 C13
p. 13 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
Status LED
A LED indicator that indicates the status by colour is located on
the top section of the automatic pay station:
Status LED
LED COLOUR DESCRIPTION
Blue Automatic pay station active
Red Automatic pay station not working /
undergoing maintenance
Green Operation successful
Automatic Pay Station power supply wiring diagram
Devices
CPU and
AUTOMATIC PAY
STATION
Additional heater
Power supply 2
Large
24 V DC - A -
230 W
Reset
command
24Vdc
Power supply 3
Medium
12 V DC - 8.5
A - 100 W
V AC [Fuse 1 A ] Internal
Lighting
Standard internal
fans and heater
V AC [Fuse 3.15 A ]
V AC [2x Fuse 12 A 120 V / 8 A 230 V ]
Power supply 1
Small
24 V DC - 2.5
A - 50 W
S2 M/T
UPS
PSONE V AC
input plug
Service outlet V AC 100 VA
(only available in 230 V version)
V AC
V AC
S1
M/T - Diff.
THE SYSTEM MUST BE ACTIVATED AND CONFIGURED AFTER INSTALLATION HAS BEEN COMPLETED.
FOR CONFIGURATION AND COMMISSIONING OF THE SYSTEM, USE THE SOFTWARE TOOL "CONFIGSETTER.EXE."
p. 14 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
Reference regulations
The product complies to the reference regulations in eect.
p. 15 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
p. 16 - Manual code: FA01290-EN v. 1- 12/2018 - © Came S.p.A. - The manual’s contents may be edited at any time without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME PSA Installation guide

Type
Installation guide

CAME PSA is a multitasking device combining functions of a ticket printer, TAG RFID proximity card reader and a color monitor with touch screen for improved user interaction. Additionally, it features payment terminals for coins and notes, ATM and credit cards for maximum user convenience. The device provides change in coins and optionally in notes, and is also equipped with barcode and QR code reader for added functionality.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI