CAME PS ONE Installation guide

Type
Installation guide
INSTALLATION MANUAL
PS ONE
PAY-TO-PARK
CONTROL SYSTEM
En
g
lis
h
EN
119GF88EN
Page
2
2 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
SUMMARY
1. System diagram ........................................................................................................................................ 3
2. Description ................................................................................................................................................ 4
3. Technical specifications ............................................................................................................................ 5
4. Wiring diagram .......................................................................................................................................... 7
5. Dimensions (mm) ...................................................................................................................................... 8
6. Example of system layout with side-by-side entrance and exit lanes .....................................................10
7. Entrance unit / exit unit card and connections - description ...................................................................12
8. Automatic pay station card - description .................................................................................................14
9. Automatic pay station card - installation .................................................................................................18
10. Entrance unit / exit unit - installation ..................................................................................................... 24
11. Entrance unit / exit unit - electrical connections ................................................................................... 25
12. Manned pay station - installation............................................................................................................ 31
Page
3
3 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
1 Pay-to-park system diagram
Magnetic
loop
Free spaces
display
Automatic
pay station
Manned pay
station
OCR
video
camera
OCR
video
camera
Barrier
Entrance unit
Exit unit
The PS ONE is designed for the use with devices with "native" Ethernet interface. This system management offers the opportunity
to configure numerous peripherals such as automatic pay stations, entry and exit units, entrances for permit holders, pedestrian
readers and manned pay stations.
Realisation of a pay-to-park system must account for specific features in order to achieve maximum usability and safety of use.
For example:
- consider all spaces and radii of vehicle manoeuvre. The entrance must comprise a space to station the vehicle in a convenient
manner for taking a ticket. We recommend a minimum distance of 2.8 m between the entrance unit and the barrier;
- Provide for pedestrian transit lanes clearly marked by vertical and horizontal signs to prevent accidents and make pedestrian
entrances and exits fast and orderly.
- Always evaluate the morphology of the site (e.g. gradients, areas with poor visibility, moving parts), to avoid collisions, dangerous
manoeuvres or danger to people. If necessary report potential risks with stripes, signs, mirrors, photocells and sensors.
Important: Ethernet connections must be ad hoc, tested and certified 10/100Mbit.
Verify the static IP addresses to be assigned to devices with your network administrator.
Assess the effectiveness of your Internet connection, which is essential for taking advantage of remote services (e.g. remote
assistance, reservations, monitoring, sending and managing alarms)
Caution! Ensure that the protective devices against overcurrent, short circuits and earth faults in primary circuits, are
installed and properly sized upstream of the system considered here.
Page
4
4 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
2 Description
Central server This is the core of the system. The server hosts the software for access
control and monitoring (even remotely) and VoIP control unit management
software for the integrated phone system.
Automatic pay station Unit for automatic payment that involves the following main functions:
- Reading and printing of tickets
- TAG RFID proximity card reading
- TFT 15.4 ’ colour monitor also available in high brightness and touch
versions.
- payment receipt
- payment in coins and notes, with ATM card and credit card (optional)
- change in coins (also available with note change option)
- barcode and QR-code reader also from smartphones
Exit unit Exit unit that involves the following main functions:
- Ticket reading
- TAG RFID proximity card reading (ISO format)
- LCD TFT colour 5.7’ monitor
- barcode and QR-code reader also from smartphones (optional)
Entry unit Entrance unit that involves the following main functions:
- ticket printing
- TAG RFID proximity card reading (ISO format)
- LCD TFT colour 5.7’ monitor
- barcode and QR-code reader also from smartphones (optional)
Manned pay station Composed of an industrial computer with touch screen 15. Depending on
your needs, the computer can be integrated with: manual ticket Barcode
reader / built-in reader, ticket printer and reader, proximity and microchip
ISO format plastic card writer / receipt printer / additional user-side display /
RFID cards reader + writer / cash drawer.
Two-sided "SPACES - FULL" lightbox sign.
Traffic light with red - green ø 200 mm lights.
Spaces display Spaces available signage panel.
Bi-channel magnetic sensor to detect metal masses
Intercom station Units installed within the local ethernet network: can only be intercom, or
upon request, video-intercom.
Vehicle classifier The system allows to automatically classify up to three classes of vehicles.
OCR video camera for reading number plates The system allows you to read and recognise the license plates of incoming
and outbound vehicles.
EYE SYSTEM cameras The system allows to associate hi-res stills of all four sides of incoming and
outbound vehicles.
UHF Long Range Antenna Automatic Identification System, of vehicles authorised access, via RFID UHF
TAG.
Page
5
5 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
3 Technical specifications
Automatic pay station
Central server
Power supply
230 V AC 50/60 Hz 3,5 A max - 120 V AC 50/60 Hz 5 A max
230 V AC 50/60 Hz 13 A max - 120 V AC 50/60 Hz 20 A max
(With optional additional heater 001PSAC142)
Absorption at rest (stand-by) 70 VA
Protection rating IP33
Weight 225 kg
Operating temperature -5°C ÷ + 55°C
-40°C ÷ + 55°C (with optional additional heater
001PSAC142)
Storage temperature 0 °C ÷ + 70 °C
Power supply 230 V - 50 Hz - 150 W
Container Micro tower
Microprocessor Dual Core 1.5 GHz AMD Turion II
RAM PC3-10600E DDR 2GB
HDD RAID - 2 x 500GB SATA drivers
Network control
Embedded NC107i PCI Express Gigabit Ethernet
Server Adaptor
Dimensions 267 x 260 x 210 mm
Weight 3 kg
Operating temperature 0 °C ÷ + 40 °C
Storage temperature 0 °C ÷ + 70 °C
Entrance unit - Exit unit
Power supply
230 V AC 50/60 Hz 2 A max - 120 V AC 50/60 Hz 3.5 A max
230 V AC 50/60 Hz 5 A max - 120 V AC 50/60 Hz 8 A max
(With optional additional heater 001PSAC143)
Absorption at rest (stand-by) 50 VA
Protection rating
IP54
Weight 54 kg
Operating temperature -10°C ÷ + 55°C
-40°C ÷ + 55°C (with optional additional heater
001PSAC143)
Storage temperature 0 °C ÷ + 70 °C
The specified characteristics are indicative. They may be changed without prior notice.
Page
6
6 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
Manned pay station
Desktop reader/printer
Power supply External 12 V / 24 V - 270 W (with supplied adapter)
Container Integrated system with ABS plastic adjustable monitor
Display 15 ' TFT LCD panel, 1024x768 w/ resistive touch
screen
Microprocessor Intel E5300 Pentium Dual Core, 2.60 GHz
RAM DDR2 512 MB
HDD 500 GB
Dimensions 382 x 356 x 388 mm
Weight 5 kg
Operating temperature 0 °C ÷ + 40 °C
Storage temperature 0 °C ÷ + 70 °C
Power supply
230 V AC 50/60 Hz 1,8 A max - 120 V AC 50/60 Hz 3,6
A max
Power draw (stand-by) 20 V A at 230 V AC / 25 V A at 120 V AC
Operating temperature 0°C ÷ +50°C
Protection rating IP20
Environmental humidity 30% ÷ 80%
Weight 2.8 kg
Overall dimensions 425x220x255 mm
Page
7
7 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
Desktop printer
ETHERNET
4 Wiring diagram
Barrier or other
operator
Barrier or other
operator
VEHICLE CROSSING
MAGNETIC loop
VEHICLE CROSSING
MAGNETIC loop
VEHICLE DETECTION
MAGNETIC loop
VEHICLE DETECTION
MAGNETIC loop
Entrance
unit
Automatic
pay station
GSM router.
I / O Interface
Central server
Intercom station
Manned pay
station
ATM reader
Receipt printer
Exit
unit
OCR video
camera
EYE SYSTEM shot
cams
Spaces display
Cabled x 1.5 mm² for 230 V a.c.
Cabled x 1.5 mm² for 230 V a.c.
Cables x 0.5 mm²
Cables x 0.5 mm²
Cabled x 1.5 mm² for 230 V a.c.
To the two-channel sensor
To the two-channel sensor
Long Range
RFID Reader
Barcode
ticket reader
Classifier
For grid connections strictly follow the IEEE standard ISO / OSI 802.3 or IEEE 802.11
Cables x 0.5 mm²


273
392
320
1190
273
2104
392
320
82
273
122
5512855
283
061
PSICD01
PSOCD01
PSI1S
PSO1S
Page
8
8 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
5 Overall dimensions (mm)
Entrance unit - Exit unit
Anchor base
Front
Please note that the units must be fixed on a base 120 at a minimum depth of 600.
Base and foundation slab





 


º
50 mm
≥100 mm
мм
Page
9
9 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
Automatic pay station
The automatic pay station must be installed in a sheltered area protected from rain, snow, dust, or other elements.
If necessary, install elements such as canopies and side panels to protect the pay station against atmospheric and environmental
agents.
The automatic pay station has been dimensioned taking into account an underlying base of about 50 mm high.
Ɗ
 


PLQ
Ɗ
Ɗ
Ɗ
Ɔ
1
2
3
6
1
9
3
9
2
5
4
7
8
7
(мин.)
Page
10
10 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
6 Example of system layout with side-by-side entrance and exit lanes
Note: the example shows the minimum dimensions (in mm) between the components of the system.
These measures are to be met for correct operation.
1. OCR video camera
2. Vehicle detection loop
3. Vehicle crossing loop
4. Exit unit
5. Classifier
6. Entrance unit
7. Barrier
8. Pit
9. EYE SYSTEM shot cam
Description of the components
ENTRY
EXIT
2 3 4
6
5
19
7
18
17
8
9
11
12
10131415
1
16
20
21
AB
Page
11
11 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
7 Entrance unit / exit unit card and connections - description
1. Traffic light fuse F1=1A-T
2. Traffic light connection terminal
3. Fan and heater connection terminal
4. Barrier connection terminal
5. LED A - Relay A active
6. LED B - Relay B active
7. R700 optional card connection terminal
8. Paper sensor connection terminal
9. Door switch connection terminal
10. CPU power supply terminal
11. Operating LED
12. Input status indicator LED
13. Input connection terminals
14. Printer power supply terminal
15. Vdc power supply inputs
16. Fan and heater fuses
F2=3.15A-T
17. TSP-00 optional connection
18. Optional RSE card connection terminal
19. RS485 optional connection
20. Optional connection OCR camera
21. Optional relay connection
+-
Page
12
12 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
Entrance - exit unit LED index input
INPUT CONDITION OF LED ON: N.B.
IN1 Vehicle presence detection of loop 1
IN2 Vehicle on Safety loop located under the barrier
IN3 Vehicle presence detection of loop 2 optional
IN4 Vehicle Classifier Axle Detection Activation optional
IN5 Vehicle Classification Photocell Free optional
IN6 Barrier open
Power supply input
2D Reader USB
connection
Compact
Flash Memory Slot
USB camera
connection
Ethernet Network
Connection
RS485
connection I/O
boards
Printer
connection
Audio interface
connection
Entrance - exit unit CPU connections
1
8
9
10
2
16
18
17
3
13
14
41112
5
6
15
7
Page
13
13 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
1. Ticket key
2. LCD Backlight
3. User keys
4. Ticket slit LED
5. Rfid Reader
6. Brightness sensor
7. Power supply and data input
8. Loud speaker
9. Audio input
10. Microphone
11. Extraction fan
12. Reserved
13. Reserved
14. Accessory power supply
15. Jumper closed
16. LH LED strip
17. RH LED strip
18. Upper LED strip
Entrance - exit unit "Connections Board"
7
8
14
14
11
1 2 3 4 5 6
10
91213
16
15
17
Page
14
14 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
8 Automatic pay station card - description
1. VAC power supply input
2. Interior lighting connection terminal
3. Fan and heater connection terminal
4. Remote alarm output terminal
5. Reset relay terminal
6. Power supply detector terminal
7. Paper sensor photocell
8. Pay station top element LED strip connection
9. Data connection
10. Input status indicator LED
11. Operating LED
12. Input connection terminals
13. Vdc power supply inputs
14. Seismic sensor connection
15. Fan and heater fuses F2=3.15A-T
16. Interior lighting fuse F1=1A-T
17. Internal siren connection
+-
Page
15
15 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
INPUT CONDITION OF LED ON: N.B.
IN1 Upper door closed (maintenance compartment)
IN2 Middle door closed (cash compartment)
IN3 Collection Drawer Fitted
IN4 Coins Drawer Fitted
IN5 Coins Drawer Engaged
IN6 Vac power present
LED index input on automatic pay station card
USB camera
connection
Reader-Printer RS232
connection
Ethernet Network
Connection
Connection
LCD Monitor LVDS
Reserved
Ethernet Connection
RS485 connection
I/O boards
2D Reader USB
connection
USB optionals
connection
Power supply
input
USB audio interface
connection
Automatic Pay Station CPU connections
6
78910
16 17 18 191514
4
13
12
11
3
2
1
5
Page
16
16 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
CCTALK card
Compact
Flash Memory Slot
CCTALK interface
RS232 connection
Receipt Printer RS232
connection
1. Activation key for card self-diagnostics TEST
2. Reserved
3. Reserved
4. CCTALK 6 Channel - connection available
5. CCTALK address selection Dipswitch
6. CCTALK 5 Channel - change return Hopper 1 connection
7. CCTALK 3 Channel - connection available
8. CCTALK 2 Channel - change return Hopper 2 connection
9. CCTALK 1 Channel - change return Hopper 3 connection
10. Power supply input
11. Voltage selection on CN6 and CN8
12. CCTALK 5 Channel - change load Hopper connection
13. RS232 from Computer
14. Reject device connection
15. Change and Receipts drawer LED connection
16. Reserved
17. Reserved
18. CCTALK 6 Channel - Coin reader connection
19. CCTALK 4 Channel - Note reader connection
LED STATUS DESCRIPTION
Green LED RUN (fl ashing ON)
Red LED ERROR (normally OFF)
Blue LED CCTALK RX line (normally OFF)
Yellow
LEDs:
CCTALK CHx line (normally OFF)
1
8
9
10
2
16
18
17
3
13
14
41112
5
6
15
7
Page
17
17 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
Automatic Pay Station Connections Board
1. Coin slot shutter
2. LCD Backlight
3. User keys
4. Ticket slit LED
5. Rfid Reader
6. Brightness sensor
7. Power supply and data input
8. Loud speaker
9. Audio input
10. Microphone
11. Coin slit LED
12. Reserved
13. Reserved
14. Accessories power supply
15. Jumper open
16. Reserved
17. Reserved
18. Reserved
Page
18
18 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
9 Automatic pay station - installation
Wear protective gloves when installing the system.
Enclose the work area and implement all
the requirements on the safe use of moving
mechanical equipment. Risk of swinging
parts
- Apply three steel cables with hooks at the end with a capacity
of at least 250 kg, in the seats on the head of the central element.
- Use a mechanical arm to tension the steel cables and then lift
the central element and bring it above the base.
- Insert the gasket between the two elements then slowly lower
the central element while making sure to centre the holes on the
base until it is supported upright.
- Release the harness.
- Fit and tighten the 10 fixing screws (supplied) of the base to the
central element.
The automatic pay station is supplied in
three elements that require assembly:
base plate
central element
top element
Base
Top element
Central element
9.1 Automatic pay station installation
gasket
Page
19
19 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
- Position the top element above the central one, and then secure the nine
screws supplied.
-Connect the LED connector to the top element on the left
side of the pay station.
- Remove the screw that secures the
printer.
Page
20
20 -
Manual Code:
119GF88EN
119 G F88 EN ver.
3
3 10/2014
© CAME cancelli automatici s.p.a. - The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S.p.a.
ENGLISH
9.2 Power supply and ETHERNET connection
- Ground the cabinet by connecting it to the site ground
connector using cables of at least 4 mm².
- Connect the ground points
between the two parts that
make up the cabinet with the supplied cable.
Power from the main electrical panel of the site to provide adequate all-pole disconnect device for
disconnecting line voltage (MCB + RCD). Required characteristics:
Circuit breaker with breaking current up to 16 A (230 V) or 25 A (120 V);
RCD with 30 mA sensitivity.
Before connecting the device, disable the external all-pole disconnecting device.
The minimum cross section of the double insulated cable must be based on the characteristics and size of the plant, and in any
event not less than 2.5 mm².
Connect the ground cable to the top element.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

CAME PS ONE Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI