www.harmanstoves.com Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 3-90-798
Model(s):
Oakleaf Wood Stove
Owner's Manual
Installation and Appliance Setup - Care and Operation
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
Please read this entire manual before
installation and use of this wood-burning
room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Donotstoreorusegasolineorotherammablevapors
andliquidsinthevicinityofthisoranyotherappliance.
• Donotoverre-Ifanyexternalpartstartstoglow,you
areoverring.Closeaircontrols.Overringwillvoid
yourwarranty.
• Complywithallminimumclearancestocombustibles
asspecied.Failuretocomplymaycauseahousere.
Checkbuildingcodespriortoinstallation.
• Installation MUST comply with local, regional, state
andnationalcodesandregulations.
• Contactlocalbuildingorreofcialsaboutrestrictions
andinstallationinspectionrequirementsinyourarea.
Testedandapprovedforusewithdry,seasonedcordwood
only.DoNotBurnWetorGreenWood.Burninganyother
typeoffuelwillvoidyourwarranty.
Hot glass will cause burns.
• Donottouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
• CAREFULLYSUPERVISEchildreninsameroomas
stove.
• Alertchildrenandadultstohazardsofhightemperatures.
High temperatures may ignite clothing or other
ammable materials.
• Keepclothing,furniture,draperiesandotherammable
materialsaway.
HOT SURFACES!
Glassandothersurfacesarehotduring
operationandcooldown.
NOTICE
To obtain a French translation of this manual, please
contactyourdealerorvisitwww.harmanstoves.com.
Pourobtenirunetraductionfrançaisedecemanuel,s’il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com.
NOTICE: SAVE THESE INSTRUCTIONS
CAUTION
!
CAUTION
!
WARNING
!
WARNING
!
WoodStove
Use&CareVideo
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1523-90-798
Hearth&HomeTechnologieswelcomesyoutoourtraditionofexcellence!BychoosingaHarmanappliance,youhavebecome
partofourcommitmenttomeetingtheheatingneedsofconsumerswiththemostdistinctive,powerfulandresponsiblehome
heatingproductsavailable.
TheOakleafhashugefeaturesinanelegantlysmallpackage,TheOakleaftakesadvantageofHarman’s30+yearsofstove
design,technologyandmanufacturing.TheFiredomesecondarycombustionsystemprovidesforsuper-cleanburningand
minimalmaintenance.Thetop-loadingfeaturemakesformoreconvenientloading,withenoughfuelforanalldayburn.
Wewishyouandyourfamilymanyyearsofenjoymentinthewarmthandcomfortofyourhearthappliance.
ThankyouforchoosingHarman.
ThisLabelislocatedontherearoftheappliance.Itcontainsimportantsafetytestinformationaswellastheclearancesto
combustiblematerials.Thelabelalsocontainstheapplianceserialnumber.Foryourrecords,copyyourserialnumberand
purchasedatehere.
Serial#:________________________  DateofPurchase:________________________
Approved For Use in Mobile/Manufactured Homes (UM) 84-HUD - USA ONLY
“PREVENT HOUSE FIRES” Install and use only in accordance with manufacturer’s installation
and operation instructions and local codes. In absence of local codes, installation must meet
minimum requirements of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for
precautions required for passing chimney through a combustible wall or ceiling.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s
manual for further information. It is against federal regulations to operate this wood heater in a manner
inconsistent with the operating instructions in the owner’s manual.
WARNING: FOR MANUFACTURED HOMES: (US Only) Do not install appliance in a sleeping room.
An outside air inlet must be provided. The structural integrity of the manufactured home’s oor, walls,
and ceiling must be maintained.
Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be factory built
103HT or masonry construction. Contact Local Building or Fire Ofcials about restrictions and
installation inspection in your area.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SERVING ANOTHER APPLIANCE.
FOR USE WITH SOLID WOOD FUEL ONLY, DO NOT bURN COAL.
EPA Certied Emissions: 2.2 g/hr
Fuel Type: Cord Wood

Optional Blower Harman #1-00-797032: Electrical Rating 115 VAC, 60Hz, 1AMP Maximum

OPERATE ONLY WITH DOORS CLOSED
Replace glass only with 5mm ceramic, available from your dealer.
Combustible ooring must be protected with an approved 0.45R hearth board.
Appliance must be installed with the legs attached. Do not obstruct
airow under the appliance.
       
    
           

     
            




352 Mountain House Road
Halifax, PA 17032
ECO:
PART # / REV: 3-90-797_RevD
ORIGINATOR: SpidleT
DATE: 04/15
LABEL SIZE: 15.5 in. x 5.875 in.
LOCATION:
CLASS:
ADHESIVE: 468
MATERIAL: METAL
INK: BLACK
OVERCOAT:
LABEL TICKET
(4) Hole Size = .60
(1) Hole Size = .125
(1) Hole Size = .125 x .25
Corners .062
CLEARANCE TO COMbUSTIbLES
DISTANCES MINIMALES DE SECURITE:

CAUTION: HOT wHIle IN OperATION. DO NOT TOUCH.
Keep CHIlDreN AND ClOTHINg AwAy. C ONTACT mAy CAUse sKIN
bUrNs. see NAmeplATe AND INsTrUCTIONs. Keep fUrNIsHINgs
AND OTHer COmbUsTIble mATerIAls A CONsIDerAble DIsTANCe
AwAy frOm THIs ApplIANCe.
ATTeNTION: CHAUD lOrs DU fONCTIONNemeNT. Ne
TOUCHeZ pAs l’AppAreIl.gArDeZ les eNfANTs eT les VÊTemeNTs ÉlOIgs. TOUT
CONTACT peUT eNTrAÎNer Des brÛlUres De lA peAU. reZ-VOUs À lA plAQUe
sIgNAlÉTIQUe eT AU mODe D’emplOI. gArDeZ le mObIlIer eT les AUTres mATÉrIAUX
COmbUsTIbles bIeN À l’ÉCArT De l’AppAreIl.
A C
D
b
           

E
F
FE

ADDITIONAL VENT CONFIGURATIONS.
US ENVIRONMENTAL PROTECTION AGENCY


BARCODE LABEL
008

N
Rev D
135-S-26-6.2
 UL1482-10, and ULC-S627-00, EPA Method 28 & 5G
Approuvé pour l'utilisation dans les maisons mobiles / Fabricant - USA SEULEMENT
"EMPêCHER MAISON INCENDIES" Installer et utiliser uniquement en conformité avec
installation et d'utilisation les instructions du fabricant et les codes locaux. En l'absence de
codes locaux, l'installation doit satisfaire aux exigences minimales de la norme NFPA 211
aux Etats-Unis. Reportez-vous aux instructions du fabricant et les codes locaux pour les précautions nécessaires pour faire
passer la cheminée à travers un mur ou un plafond combustible.
Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. Consultez le manuel du
propriétaire pour plus d'informations. Ce est contre les règlements fédéraux pour faire fonctionner ce poêle à bois d'une
manière incompatible avec les instructions d'utilisation dans le manuel du propriétaire.
 (États-Unis uniquement) Ne pas installer l'appareil dans une chambre
à coucher. Une entrée d'air extérieur doit être fournie. L'intégrité structurale du sol, les murs et le plafond de la maison
préfabriquée doit être maintenue.
Tuyau de raccordement de fumée doit être de 6 "de diamètre, en acier au minimum 24 MSG bleu. Cheminée doit être
construite l'usine 103HT ou la construction de maçonnerie. Contactez Immeuble Local ou fonctionnaires incendie au sujet
des restrictions et l'inspection d'installation dans votre région.


Émissions certiés EPA: 2,2 g / h
Type de carburant: Cordon bois

Facultatif Blower Harman # 1-00-797032: Note électrique 115 VAC, 60Hz, 1AMP maximum


Remplacer le verre seulement avec de la céramique 5mm, disponible chez votre revendeur.
Plancher combustible doit être protégé par un conseil 0.45R foyer approuvé.
L'appareil doit être installé avec les jambes attachées. Ne pas obstruer le ux d'air sous l'appareil.
  

          







Room Heater Solid Fuel Burning Type
SUITABLE FOR MOBILE-HOME INSTALLATION (USA ONLY)
C
D
b
A
 Inches Millimeters
Back Wall / Entre mur arriereet l’appareil
Side Wall To Unit / Entre mur lateral et l’appareil
Back Wall To Flue Pipe / Entre tuyau et le mur arriere
Side Wall To Flue Pipe / Entre tuyau et le mur lateral
14
17
17-1/2
26-3/4
330
432
444
679
Walls to Unit Body / Entre mur adjacent et l’appareil
Walls to Flue Pipe / Entre tuyau et le mur adjacent
F
E
 Inches Millimeters
14
21-3/4
330
552
G
G
H
J
           




     


Sides / Côtés
Front- from glass/Devant, par rapport au verre
Rear / Arrière
J
H
G
 Inches Millimeters
8
18
8
203
457
203

2015 2016 2017 JAN feb mAr Apr mAy JUN JUl AUg sep OCT NOV DeC

Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 33-90-798
TABLE OF CONTENTS
This room heater must be connected to:
1. A chimney complying with the requirements for
Type HT chimneys in the standard for Chimneys,
Factory-Built, Residential Type and Building Heating
Appliance, UL 103
OR
2. A Code Approved Masonry Chimney with a Flue
Liner.
1 Listing and Code Approvals
A. ApplianceCertication............................4
B. MobileHomeApproval............................4
C. GlassSpecications..............................4
D. ElectricalRating.................................4
E. BTU&EfciencySpecications.....................4
2 Special Warnings and Notes
A. CarbonMonoxideWarnings&Considerations .........5
3 Getting Started
A. Design,InstallationandLocation....................6
B. FireSafety.....................................6
C. ComponentLocator.............................. 7
D. FlueDirectionConversion.........................7
E. Pre-UseChecklist................................8
4 Dimensions & Clearances
A. ApplianceDimensions............................ 9
B. ClearancestoCombustibles ......................10
C. FloorProtection................................12
5 Chimneys and Venting
A. Draft.........................................13
B. ChimneyConnectors............................ 13
C. WallPass-throughs .............................13
D. TheChimney..................................14
6 Mobile Home (US Only)
A. MobileHomeInstallation.........................21
7 Appliance Set-Up
A. OutsideAirAttachment...........................22
B. LevelingtheAppliance...........................22
C. OptionalCookingGrill ...........................22
D. OptionalBlowerKit..............................23
E. OptionalRearVentShield ........................23
F. BottomHeatShield .............................23
8 Operating Instructions
A. FuelSpecications..............................24
B. GeneralOperatingInformation.....................24
C. CombustionProcess ............................25
D. UserControls..................................26
E. BeforeYourFirstFire............................26
F. BuildingandMaintainingaFire ....................26
9 Service & Maintenance
A. SootFormation(Removal)........................28
B. GeneralMaintenanceProcedures..................29
10 Reference Materials
A. WiringDiagram(OptionalBlower)..................31
B. ServicePartsList...............................32
C. WarrantyPolicy ................................35
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1543-90-798
A. Appliance Certication E. BTU & Efciency Specications
1 Listing and Code Approvals
B. Mobile Home Approved
This appliance is approved for Installation in mobile/
manufactured homes in the US only. The structural
integrityofthemobilehomeoor,ceilingandwallsmustbe
maintained. The appliance must be properly grounded to
theframeofthemobilehome,andmustneverbeinstalled
in a room designated for sleeping. The unit must have
provisions for an outside air source when installed in a
mobilehome.
C. Glass Specications
This appliance is equipped with 5mm ceramic glass.
Replaceglassonlywith5mmceramicglass.Pleasecontact
yourdealerforreplacementglassifneeded.
D. Electrical Rating
OptionalBlower:115VAC,60Hz.<1Amps
TheOakleafWoodburningStoveisCertied
to comply with 2015 particulate emission
standards.Not approvedfor sale after May
15,2020.
MODEL: OakleafWoodburningStove
LABORATORY: OMNITestLaboratories,Inc
REPORT NO. 135-S2-26-6.2
TYPE: SolidFuelRoomHeater/Wood
BurningType
STANDARD(s): UL1482-10,&ULCS627-00,EPA
Method28&5G
ELECTRICAL
RATING:
115VAC,60Hz
EPA Certication Number: 898
EPA Certied Emissions: 2.2g/hr
*LHV Tested Efciency: 63%
**HHV Tested Efciency: 70.9%
***EPA BTU Output: 9,700-24,600
****BTU Input 45,100
Vent Size: 6Inch
Recommend Log Lenght: 18"Maximum
Fuel SeasonedCordWood
* Weighted average LHV efciency using data collected
during EPA emissions test.
**Weighted average HHV efciency using data collected
during EPA emissions test.
***A range of BTU outputs based on EPA Default Efciency
and the burn rates from the low and high EPA tests.
****Based on the maximum burn rate multiplied by
approximately 8600 BTU’s which is the average BTU’s per
pound of wood with an average moisture content of 20%.
Thiswoodheaterneedsperiodicinspectionandrepairfor
properoperation.Itisagainstfederalregulationstooperate
this wood heater in a manner inconsistent with operating
instructionsinthismanual.
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 53-90-798
2 Special Warnings and Notes
NOTICE
Due to ash buildup, it is strongly recommended to
have your stove professionally cleaned and serviced
annually. This includes all parts of the stove, and the
venting system.
Installation and repair of this stove should be done
by a qualied service person. We recommend that the
stove be inspected before use and at least annually
by a qualied service person. Periodic cleaning is
required throughout the heating season and at the
end of each winter for the stove to work efciently.
Carbonmonoxide,referredtoasCO,isacolorless,odorless
gasthatisproducedduringcombustionofwoodandother
fuels.CO fumes are toxic and can be fatal.
The Oakleaf is a natural draft system which relies on
a properly designed chimney to remove CO and other
combustionby-productsfromthestove.
Eventhoughthisstoveisdesignedtobeassafeaspossible,
itisimportantthatyouinstall a CO detector.Thisistruefor
oil,gas,orcoalburningproductsaswell.
COisnotspecicallyheavierorlighterthanair.Therefore,
itisbesttoinstallthedetectorattabletoplevelratherthan
ontheceilinglikeasmokedetector.
COdetectorsareverysensitiveand maysoundanalarm
forfumesotherthanCOorCOfromsourcesotherthanthe
stovesuchascarorlawnmowerexhaust.
If the alarm sounds
1.Increaseventilationbyopeningwindowsordoors.
2.Makesurethestovedoorsandlidareclosedandlatched.
3.Checkstoveforsmokingorpufngcondition.Openby-
passandincreaseair-owtorebox,ifneeded.
4.Checkchimneyforpossibleblockageordown-draft.
5.Checkforfalsealarm.
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY
INSTALLED, OPERATED AND MAINTAINED, A HOUSE
FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW
INSTALLATION DIRECTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS
AND INSTALLATION INSPECTION REQUIREMENTS IN
YOUR AREA.
WARNING
!
THIS WOOD HEATER HAS A MANUFACTURER-SET
MINIMUM LOW BURN RATE THAT MUST NOT BE
ALTERED. IT IS AGAINST FEDERAL REGULATIONS
TO ALTER THIS SETTING OR OTHERWISE OPERATE
THIS WOOD HEATER IN A MANNER INCONSISTENT
WITH OPERATING INSTRUCTIONS IN THIS MANUAL.
BURNING COLORED PAPER, CARDBOARD,
SOLVENTS, TRASH AND GARBAGE OR ALTERING
THE STOVE FOR HIGHER HEAT OUTPUT MAY CAUSE
DAMAGE TO THE STOVE AND COULD RESULT IN
A HOUSE FIRE. USE ONLY APPROVED FUELS AND
FOLLOW ONLY THESE OPERATION GUIDELINES.
WARNING
!
NEVER USE GASOLINE, LANTERN FUEL, KEROSENE,
CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR “FRESHEN UP” A FIRE IN THIS HEATER.
KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE
HEATER WHILE IT IS IN USE.
WARNING
!
NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
WARNING
!
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM.
WARNING
!
WHEN THIS ROOM HEATER IS NOT PROPERLY
INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE
THE RISK OF FIRE, FOLLOW THE INSTALLATION
INSTRUCTIONS. CONTACT LOCAL BUILDING OR
FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION REQUIREMENTS IN
YOUR AREA.
CAUTION
!
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1563-90-798
A. Design, Installation & Location
Considerations
1. Appliance Location
Considerationmustbegiventosafety,convenience,trafc
ow,andthefactthattheappliancewillneedachimneyand
chimneyconnector.Itisagoodideatoplanyourinstallation
on paper, using exact measurements for clearances and
oor protection, before actually beginning the installation.
When installing on a combustible oor, the bottom heat
shield must be installed along with using proper oor
protectionmaterial.SeeSection4Cfordetails.
Maintain specied vent clearance to combustible
requirementslistedbytheventmanufacturersinstructions
andallclearancetocombustibleslistedinthismanual.
Checkwithyourlocalbuildingcodeagencybeforeyoubegin
yourinstallation.BesurelocalcodesdonotsupersedeUL
specications and always obtain the required permit so
thatinsuranceprotectionbenetscannotbeunexpectedly
cancelled.Ifanyassistanceisrequiredduringinstallation,
pleasecontactyourdealer.
Werecommendthataqualiedbuildinginspectorandyour
insurancecompanyrepresentativereviewyourplansbefore
andaftertheinstallation.
Be sure to provide a source of fresh air to the room or
directlytotheappliance.Make-upairisneededtoreplace
whatthechimneydrawsawaythroughtheappliance.
B. Fire Safety
Maintain the designated clearances to combustibles.
Insulationmustnottouchthechimney.Youmustmaintain
thedesignatedairspace around the chimney.Thisspace
around a chimney is necessary to allow natural heat
removalfromthearea.Insulationinthisspacewillcausea
heatbuildup,whichmayignitewoodframing.
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction.
To provide reasonable re safety, the following should be
givenseriousconsideration:
1. Installatleastonesmokedetectoroneachoorofyour
home.Detectorsshouldbelocatedawayfromtheheating
applianceandclosetosleepingareas.Followthesmoke
detector manufacturer's placement and installation
instructions,andbesuretomaintainregularly.
2. A conveniently located Class A re extinguisher to
contendwithsmallresresultingfromburningembers.
3. A practiced evacuation plan, consisting of at least two
escaperoutes.
4. Aplantodealwithachimneyreasfollows:
 Intheeventofachimneyre:
a. Evacuatethehouseimmediately.
b. NotifyFireDepartment.
c. Never apply water to a suspected chimney re.
Seriousdamagecouldoccur.
3 Getting Started
Do NOT connect this unit to a chimney ue servicing
another appliance.
Do NOT connect to any forced air distribution duct
or system.
CAUTION
!
FIRE HAZARD
DO NOT OPERATE APPLIANCE BEFORE
READING AND UNDERSTANDING THE
OPERATING INSTRUCTIONS.
FAILURE TO OPERATE PROPERLY MAY
CAUSE A HOUSE FIRE.
WARNING
!
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 73-90-798
C. Component Locations
D. Flue Direction Conversion
TheOakleaffeaturesanadjustableuecollarforrearortopexit.Followtheseinstructionsforchangingthedirection.First,
removetheupperrearheatshieldbyremoving8Tekscrewsthatsecureit.Reachingupwardthroughthereboxandtheopen
bypassdamper,loosentheretainerboltsoneachoftheuecollarandthecastironplate.Withtheboltsloosened,turnthe
retainertoallowthepiecetocomefreeofthestovebody.Repositiontheuecollarandthecastironplateandsecurethem
withtheretainersbytighteningthebolts.Youwillnowneedtoinstalladifferentupperrearheatshield.(SeeSection7E).
Top Load Opening
Air Control
Front Load Door
Top Load Door
Bypass Damper
Control Handle
Ash Door
Ash Door
Latch
Front Load
Door Latch
Level
adjuster
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1583-90-798
E. Pre- Use Check List
1. Placetheappliancein a location near thenal
installationandfollowtheproceduresbelow:
2. Open the appliance and remove all articles
packedinside.Inspectallitemsforshipping
damage. Notify dealer of any missing or
damagedgoods.
3. Allsafetywarningshavebeenreadandfollowed
precisely.
4. This Owner's Manual has been read in it's
entirety.
5. Floor protection requirements have been read
andfollowed.
6. The ue connector has been installed in
accordancewiththeinstructionsherein.
7. The proper clearances from the appliance and
chimneyconnectortocombustibles h a v e
beenmet.
8. The masonry chimney has been cleaned and
inspectedbyaprofessional,orthefactorybuilt
metal chimney is installed according to the
manufacturersinstructions.
9. The chimney meets the minimum height
requirements.
10. All labels and hang tags have been removed
fromtheglass.
11. All plated surfaces have been wiped clean, if
applicable.
12. The optional air distribution blower has been
installedproperly.
13. A properly grounded electrical receptacle is
availablewithinreachoftheblower'spower
cord(ifinstalled).
TherearetwobrickclipslocatedintheOwner’smanualbag.Withthebricksinplace,installtheclipsinthefrontcornersas
shown.Thelongportionoftheclipwilltbetweenthebrickandthewallofthestove,withtheshorthookover-hangingto
theinsideoftherebox.
INSPECT APPLIANCE AND COMPONENTS
FOR DAMAGE. DAMAGED PARTS MAY
IMPAIR SAFE OPERATION.
DO NOT INSTALL DAMAGED
COMPONENTS.
DO NOT INSTALL INCOMPLETE
COMPONENTS.
DO NOT INSTALL SUBSTITUTE
COMPONENTS.
REPORT DAMAGED PARTS TO DEALER.
WARNING
!
FIRE RISK.
HEARTH & HOME TECHNOLOGIES
DISCLAIMS ANY RESPONSIBILITY FOR,
AND THE WARRANTY WILL BE VOIDED
BY, THE FOLLOWING ACTIONS:
WARNING
!
INSTALLATION AND USE OF ANY DAMAGED APPLIANCE.
MODIFICATION OF THE APPLIANCE.
INSTALLATION OTHER THAN AS INSTRUCTED BY
HEARTH & HOME TECHNOLOGIES.
INSTALLATION OF PARTS OR COMPONENTS NOT
SUPPLIED OR APPROVED BY HEARTH & HOME
TECHNOLOGIES.
OPERATING APPLIANCE WITHOUT THE LEGS
ATTACHED.
OPERATING APPLIANCE WITHOUT FULLY ASSEMBLING
ALL COMPONENTS.
DO NOT OVERFIRE.
OR ANY SUCH ACTION THAT MAY CAUSE A FIRE HAZARD.
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 93-90-798
A. Appliance Dimensions
25"(635mm)
26-1/4"
(667mm)
27-1/4"
(692mm)
29-1/4"
(743mm)
18-15/16"
(480mm)
25-5/8"
(650mm)
Centered
27-5/8"
(701mm)
When congured for rear ue; Floor to center of ue measures 23-1/2" (597mm)
NOTICE: When using rear ue conguration, a new upper rear heat shield, #1-00-797066 must be installed in place
of the existing shield.
4 Dimensions & Clearances
Air Intake
10-1/4"
(260mm)
C
L
23-1/2"
(597mm)
C
L
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1510 3-90-798
B. Clearances To Combustibles
Pipe clearance may be reduced using double wall or
insulated connector pipe, provided that you adhere
to the specied clearances from the stove itself.
Follow pipe manufacturer's guidelines.
*NFPA 211 species 18" clearance to single wall
connector pipe. This lower clearance is based on
actual safety test conditions.
Pipe clearance may be reduced using double wall or
insulated connector pipe, provided that you adhere to the
specied clearances from the stove itself. Follow pipe
manufacturer's guidelines.
*NFPA 211 species 18" clearance to single wall connector
pipe. This lower clearance is based on actual safety test
conditions.
E
D
B
C
A
E
F
C
A
C
A
*D B
Vertical Venting Conguration
Location Single-Wall Pipe
AUnittoSideWall 17"/432mm
BUnittoBackWall 14"/356mm
CVentPipetoSideWall 26-3/4"/679mm
DVentPipetoBackWall 17-1/2"/444mm
For clearance reduction methods, refer to NFPA 211 or Local Codes
Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the
unit to ceiling.
This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–
Burning Appliances".
Vertical Vent, Horizontal Exit
Location Single-Wall Pipe
AUnittoSideWall 16"/407mm
BUnittoBackWall 13"/330mm
CVentPipetoSideWall 25-1/4"/641mm
DVentPipetoBackWall *17"/432mm
EVentPipetoCeiling *16"/407mm
FMinimumVertical 0"/0mm
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 113-90-798
A
B
CLEARANCE TO COMBUSTIBLES: Corner Installation,
Vertical Vent
CLEARANCE TO COMBUSTIBLES: Corner Installation
Vertical Vent, Horizontal Exit.
CLEARANCE TO COMBUSTIBLES: Horizontal Venting Conguration
Pipe clearance may be reduced using double wall or insulated connector pipe, provided that you adhere to the specied
clearances from the stove itself. Follow pipe manufacturer's guidelines.
(Although vent clearance may be reduced using double-wall pipe, D must be followed)
A
B
B
A
C
A
E
D
D
Location Single-Wall Pipe
AShieldCornertoWall 14"/356mm
BVentPipetoWall 21-3/4"/552mm
Location Single-Wall Pipe
AShieldCornertoWall 14"/356mm
BVentPipetoWall 21-3/4"/552mm
Location Single-Wall Pipe
AUnittoSideWall 17"/432mm
BUnittoBackWall 13"/330mm
CVentPipetoSideWall 26-1/2"/673
Corner Installation
DShieldCornertoWall 14"/356mm
ENFPA211Seciesclearanceof 18"/457mm
For clearance reduction methods, refer to NFPA 211 or Local Codes
NOTICE: When using rear ue conguration, a new upper rear heat shield, #1-00-797066 must be installed in place
of the existing shield.
Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–Burning Appliances" for clearance from the top of the unit
to ceiling.
This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel–
Burning Appliances".
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1512 3-90-798
C. Floor Protection Requirements
Floor Protection Requirements
IftheOakleafisbeinginstalledonacombustibleoor,the
bottomheatshield(part#1-00-797058)mustbeinstalled
with a suitable material for oor protection. (See Section
7F).Thisheatshieldissuppliedwiththeunitandmustbe
installed.Floorprotectionmustbeatleast3/8"(9.5mm)thick
insulatingmaterialhavingavalueequaltoorgreaterthan
0.84k/in.(Thehigherthevalueofk,thebettertheprotection.)
AnothermethodforcalculatingoorprotectionisinRvalue.
ThisrequirementwouldbeforanRvalueof0.89orhigher.
(ThehighertheRvalue,thebettertheprotection).
Inallinstallations,theareaunderandaroundthestovemust
beprotectedfromfallingashandlivecoals.The area under a
horizontal run of chimney connector must also be protected,
extending two (2) inches beyond the measurement of the
horizontal connector.
Furtherguidelinesforoorprotectionareasfollows:
IntheU.S.theoorprotectormustbecompletelyunderthe
stove,andextending18"infrontofthedooropening,8"to
eachsideand8"totheback.
InCanada, the oor protection mustextend 18"(457mm)
infrontofthedooropening,8"(203mm)toeachsideand
extendtothewallbehindthestove.
MinimumSizeoorprotection(USA)is42-3/4"Deepby32-
5/8"Wide.
Floorprotectiontouchingthewall:53-3/8" Deepx32-5/8"
Wide.
DANGER: The appliance legs may not be removed for
installation.
MinimumSize oor protection (USA) is 32-5/16" WideBy
43-3/8"Deep.
Parallel versus Corner Installations
Aparallelinstallationisoneinwhichthebackandsidesof
thestoveareparalleltothewallsbehindandtothesideof
thestove.Acornerinstallationisoneinwhichthebackofthe
stoveispositioneddiagonallyacrossacorneroftheroom.
Eachinstallationrequiresitsownsetofclearances.
For corner installations, the required clearance distances
fromthestoveare:
1.tothesidewall,14"(356mm).
2.Fromtheueconnectortothewall,21-3/4"(552mm)
3.Horizontalpipetotheceiling,16"(406mm).
Foraverticalchimneyconnectorinaparallelinstallationthe
distanceoftheconnectortothesidewallmustbe26-3/4"
(679mm),dueto the requiredside clearance ofthestove
itself.Fireplaceinstallationsmustmeetthesesameclearance
requirements;specicallyfollowtheseguidelinesformantel
andtrimclearances.
For corner installations, the clearance distances are 14"
(356mm)fromeachcornerofthestovemeasuredstraight
back to the nearest combustible material, and 21-3/4"
(552mm)fromthechimneyconnectortothewalls.Tostay
withintheseclearancesandhavetheoorprotectortouch
theinterior wall itmust be ahearth pad sizeof 53" x53"
(USAONLY).
Alternate oor protector dimension may be used as long as
they satisfy the measurement requirements shown above.
TypeIIoorprotectionmustbeused.
*Floorprotectionforthefrontandsidesasmeasuredfrom
theappliancedooropening.
60”
60”
Interior Wall
Interior Wall
Minimum size oor protection for a corner installation hearth
pad is 43-3/8" x 32-5/16" (USA ONLY). NOTE: Floor protector
WILL NOT touch the wall.
J
JK
L
Floor Protection
Requirements US Canada
JSides 8" 203mm
KFront 18" 457mm
LRear 8" Wall
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 133-90-798
5 Chimneys and Venting
A. Draft
Draftiswidelymisunderstood.Itisimportantthatyou,the
stoveoperator,realizethatdraftisavariableeffect,nota
givenquantity.Stovesandchimneysdonothavedraft,yet
draftisthekeytoyourstove’sperformance.
Draft is a force, produced by an operating stove and the
chimneytowhichitisattached.Itiscreatedbyhotgases
risingupthechimney,creatingapressuredifferencebetween
theinside ofyour homeand the outside air. It continually
movesfreshcombustionairintothestove,andhotexhaust
gasesoutof the stove;without this constantow, there
willgoout.
Other factors, such as barometric pressure, winds, the
airtightnessofthehome,thetotalinsidechimneyvolume,
chimneyheightandthepresenceofventingdevicessuch
asexhaustfansalsoplayaroleinmaintaininganadequate
draft. Low barometric pressures, super insulated homes
andexhaustfanscanreducedraft;windscanplayhavoc
withdraft;andtoolargeortoosmallachimneyvolumecan
cause reduced draft due to the excessive cooling or not
enoughroomtoventexhaustgases.Introducingoutsideair
directlytothestovemayhelpremedyalowdraftproblem.
Somesignsofinadequatedraftaresmoking,odor,difculty
inmaintainingthere,andlowheatoutput.Overdraftcanbe
causedbyaverytallchimneyevenifitistherecommended
size, and can cause overring of your stove. Signs of an
overdraft include rapid fuel consumption, inability to slow
there,andpartsofthestoveorchimneyconnectorglowing
red.Itisimportantthatyoufollowthechimneyguidelinesin
thismanual,includingsize,type,andheighttoavoiddraft
problems.
Wheninstalledandoperatedaccordingtothismanual,the
Oakleafwillproduceenoughhotgasestokeepthechimney
warmsothatadequatedraftismaintainedthroughoutthe
burncycle.
B. Chimney Connectors
Ingeneral,followingtheseguidelineswillensurecompliance
withallnationalandprovincialcodes;priortobeginningyour
installation, check with your local building code ofcial to
checkonadditional local regulationswhichmay inuence
thedesignandplacementofyourventingsystem.
The Harman Oakleaf may be installed with a minimum
(.6mm)24gaugechimneyconnectorpipe.Thesizeofthe
connectorshould correspondto thesize ofthe uecollar
opening.Donotusemakeshiftcompromises.Nopartofthe
chimneyconnectormaypassthroughanatticorroofspace,
closetorotherconcealedspace,orthroughaoororceiling.
Wheneverpossible,avoidpassingtheconnectorthrougha
combustiblewall;ifyoumust,useanapprovedwallpass-
through,describedlaterinthissection.
The Chimney Connector Shall Not Pass Through an Attic or Roof
Space, Closet or Similar Concealed Space, a Floor or Ceiling.
Assembletheconnectorbeginningattheuecollar,withthe
crimpedendspointingtowardsthestove(tokeepdebrisor
residueinsidethesystem).Eachjoint,includingtheonetothe
stove’suecollarandtheonetothechimneyitselfshouldbe
securedwithatleastthreesheetmetalscrews.Screwsmay
beamaximumof3inchesapart.A1-1/4"(30mm)overlapis
requiredateachjoint,includingtheuecollarattachment.
Nomorethantwo90°elbowsshouldbeused,andthetotal
length of connector should not exceed 10 feet (3m).All
horizontalrunsofconnectormusthaveaminimumupward
slopeof1/4"(6mm)perfoot(20mmpermeter).
The chimney connector diameter should correspond to
the size of the ue collar opening. Do not use makeshift
compromises.Nopartofthechimneyconnectormaypass
through an attic or roof cemented in place with refractory
cement.
C. Wall Pass-throughs
Dependingonyourlocalbuildingcodes,andthepertinent
provincialornationalcodes,thereareseveralchoicesfor
passingthechimneyconnectorsafelythroughawall.Before
beginningyourinstallation,contactlocalofcials,andalso
thechimneyconnectorandchimneymanufacturerforspecic
requirements.
Canada. Three methods are approved by the Canadian
StandardsAssociation.Thediagramonthenextpageshows
onemethodrequiringan18"(450mm)airspacebetweenthe
connectorandthewall.Itallowsuseofoneortwocovers
as described in the diagram.The two other methods are
describedindetailinthecurrentissueofCAN/CSAB365,
thenationalstandard.
United States IntheU.S.,thenationalcodeisNFPA211.
Whilemanylocalitiesadoptthisstandard,besuretocheck
withlocalauthoritiesbeforebeginningyourinstallation.
The NFPA (National Fire ProtectionAgency) permits four
methodsforpassingthroughacombustiblewall.Acommonly
usedmethodtopassthroughawalldirectlytoamasonry
chimneyistoclearaminimum12"(300mm)aroundtheentire
chimneyconnector,andllitwithbrickmasonrywhichisat
least3.5"(90mm)thick.Areclayliner,minimum3/8"(9mm)
wallthicknessmustrunthroughthebrickwalltothechimney
liner(butnotbeyondtheinnersurfaceoftheliner).Itmust
becementedinplacewithrefractorycement.Thismethod
isillustratedonthenextpage.Fordetailsontheotherthree
options,refertothemostrecenteditionoftheNFPA211code.
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1514 3-90-798
D. The Chimney
Thisunitmustbeinstalledintoachimneyapprovedforuse
withsolid-fuelappliances.IntheU.S.,itmustbeconnectedto
(1)aprefabricatedchimneycomplyingwiththerequirements
forTypeHTchimneysintheStandardforChimneys,Factory-
Built,ResidentialTypeandBuildingHeatingAppliances,UL
103,or(2)acode-approvedmasonrychimneywithaue
liner.
In Canada, this unit is listed for use with prefabricated
chimneystestedandlistedtothehightemperature(650°C)
chimney standard, ULC S-629, or with a code approved
masonrychimney.
Formobilehomes,(USonly)itmustonlybeinstalledwith
afactorybuiltstainlesssteelchimney.Thechimneysystem
shouldincludeallrequiredinstallationcomponents,suchas
vaporbarriersandroofashing,astestedforuseinmobile
homes.
Theminimumrecommendedheightforanychimneyis16
ft. (4.8m) above ue collar height. For non-mobile home
installations, a round flue (either masonry or approved
prefabricated),ofeither6"(150mm),7"(180mm)or8"(200
mm) may be used. For square or rectangular masonry
chimneys,nominal sizes of 8" x 8" or 7" x12" (200mm x
200mm,180mmx300mm)maybeused.
Codesrequirethatsolid-fuelchimneysextend3ft.(0.9m)
abovethehighestpointatwhichtheyexitfromtheroof.Then,
thechimneymustextend2ft.(0.6m)abovethehighestpoint
withina10ft(3m)radius.Thus,the3foot,2foot,10footrule:
3ft.-Aboveroofexitpoint
2ft.-Higherthananythingwithin-
10ft. ofthechimney.
NOTE:Therestrictionofnotventingmorethanoneappliance
tothesameueappliestotheU.S. specically.Whileitisnot
recommendedthatyouusethesamechimneyformorethan
oneappliance,inCanadacertainexceptionsmaybemade.
Besuretocontactyourbuildingcodeinspectionofcialto
seeifthisoptionisallowedinyourarea,andtondoutthe
specicrequirementsforsuchaninstallation.
Do not connect this unit to a chimney ue servicing
another appliance.
Hole with minimum
clearance of 18”
(450mm) Between
connector and wall.
Non-combustible cover, one
side only. If two covers are
used, each must be mounted
on non-combustible spacers
at least 7/8” (21mm) away
from the wall.
1” (25mm)
Clearance
AN APPROVED CANADIAN WALL PASS-THROUGH
AN APPROVED U.S. WALL PASS-THROUGH
Minimum 2” (50mm)
Clearance to Brick
Liner Minimum 12”
(50mm) to Brick
Fire Clay
Thimble
Chimney
Connector
Chimney Flue
Masonry Chimney Built to
NFPA 211 Specifications
Closest Combustible Material
Minimum 12” (300) to
Combustibles
AN APPROVED CANADIAN WALL PASS-THROUGH AN APPROVED U.S. WALL PASS-THROUGH
More than 10 Ft. (3 m)
10 Ft. (3 m)
2 Ft. (.6 m) Min
Height necessary
above any roof surface
within 10 Ft. (3 m)
3 Ft. (.9 m) minimum
above exit point
Ridge
Chimney
THE 3-FOOT, 2-FOOT, 10 FOOT RULE
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 153-90-798
Existing Masonry Chimneys
Ifyouplanonusingapre-existingmasonrychimney,have
itthoroughlyinspectedandcleaned.Anyfaultswhichmake
thechimneyunsafeandunusablemustberepairedpriorto
use.Thesecanincludeimproperheight,structuraldefects,
blockages,inadequateclearancetocombustibles,unsealed
openingsintootherroomsofthehouse,signsofcreosoteor
smokeleakage,alooseorabsentclean-outdoor,orabsence
ofaliner.
Venting to a Masonry Chimney
Whenconnectingtoamasonrychimney,severalprovisions
arestandard.First,whetherthechimneyconnectorisvented
tothechimneythroughathimbleorabreechpipe,neither
must pass beyond the inner surface of the chimney liner,
andbothmustbermlycementedinplacewithrefractory
cement. (A thimble is a masonry pipe which is inserted
through the chimney wall, and is frequently the preferred
method;abreechpipeisapieceofsteelpipeusedthesame
way.)InCanada,abreechpipehasridgesorprotrusionsto
lockitrmlyintotherefractorycement.Ineithercase,the
chimneyconnectorventstothechimneythroughthethimble
orbreechpipe.
Usingathimble,theconnectorslidescompletelyinsidethe
masonrytotheinneredgeoftheueliner,andmaybeeasily
removed for chimney and connector inspection.A breech
pipemustextendatleast2"(50mm)intotheroom,sothe
connectorcanbeattachedwithsheetmetalscrews.
Venting to a Masonry Fireplace Chimney
In some situations, a code compliant chimney originally
usedforamasonryreplacemaybeused.Inadditiontothe
requirementsfoundinthepreviousparagraphs,itisimportant
tobeawarethatallclearancesmustbemet,includingthose
fromthechimneyconnectortocombustibles.Donotforgetto
includeoorprotectioninyourplans.(SeeClearancesand
FloorProtectioninthissection.)Sincemanyreplaceshave
exposedwoodenmantelsandtrim,payspecialattentionto
theclearancesnecessarytothesematerials.
Ifyourreplacechimneyisbehindacombustiblewall,you
must use an approved wall pass-through system to gain
access to the masonry chimney. The chimney connector
must enter the chimney at a place where it is lined, and
thereplacemustbemadeinoperable.Forexample,you
mightremovethedamper,replacingitwithasecure,airtight,
noncombustible seal (removable for inspection); this also
satisestherequirementthatnoroomairmustbeallowed
toenterthechimney.
Installing to a Prefabricated Chimney
When venting using a prefabricated chimney, be sure
to contact local building code authorities, and to follow
the manufacturer’s instructions exactly. Use only the
manufacturer’s parts; do not use makeshift installation
techniques.All prefabricated chimneys must be tested to
eithertheU.S.orCanadianhigh-temperaturestandards,UL
103orULCS629.
Other Considerations
Donotburnanyfuelotherthandrycordwood.Neveruse
highlyvolatilesubstancesinyourstove,suchasgasoline,
whichcouldcauseanexplosion.
When solid fuels are burned completely, they produce
waterandcarbondioxide.However,inlongslowburns,a
substantialamountofcarbonmonoxidemaybeproduced.
Ifallowedtobuildup,carbonmonoxide(whichisodorless)
canprovefatallypoisonous.Properventilationanddraftwill
preventthisfromhappening.Ifyousmellsmoke,thoroughly
ventilateyourdwelling,andcontactyourdealerforservice.
Othercausesofpoorventilationordraftareicing,exhaust
fans,ablockedoutsideairinlet,androomairstarvation.If
yourstoveissluggishandyougetoccasionalodor,check
thesepossibilitiesandincreasetheairowinyourhome.
Chimney
Connector
Clay thimble, reaching
just to the inside of the
chimney liner
Mechanical fasteners
(minimum 3) but not at the
bottom of the connector
Chimney liner
inner edges
High-temperature
sealant used to cement
the clay thimble
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1516 3-90-798
Standard Ceiling Installation with
Factory Built Chimney
Cathedral Ceiling Installation with
Factory Built Chimney
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Chimney Connector
Minimum air space
with chimney listing
Chimney support
Attic radiation shield
Chimney sections
Chimney cap
Storm collar
Roof flashing
Roof radiation
shield
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
Chimney Connector
Cathedral style
chimney support
Finishing collar
Roof radiation shield
Chimney cap
Sealed storm
collar
Roof flashing
Factory-Built metal
chimney
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 173-90-798
Chimney Breach Fireplace Conversion with Non-Combustible Wall
Minimum clearance to
unprotected ceiling 15”
Chimney connector
sealed at thimble
Flue liner with required air space
Minimum of three sheet
metal screws per joint of
chimney connector
Mantel and trim protection
Airtight
insulated
clean-out
Damper closed
and sealed with
material
Combustible Floor
Floor Protection*
*Floor protection in accordance with Solid Fuel Appliance Listing
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1518 3-90-798
Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection)
NOTICE: When using rear ue conguration, a new upper rear heat shield, #1-00-797066 must be installed in place
of the existing shield.
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Combustible Floor
Airtight
insulated
clean-out
Flue liner with required air space
Floor Protection*
Stainlesssteel chimney connector
must extend to flue liner
Minimum 8” masonry thickness in
front of smoke chamber
Use damper adapter or seal with
non-combustible material
Damper plate is removed or
fastened in open position
*Floor protection in accordance with solid fuel appliance listing
Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15 193-90-798
Full Relining Fireplace Conversion: Freestanding Appliance
NOTICE: When using rear ue conguration, a new upper rear heat shield, #1-00-797066 must be installed in place
of the existing shield.
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Combustible Floor
UL1777 Stainless steel liner system or other
approved lining system
Floor Protection*
Follow liner manufacture’s instructions
on insulation and support
UL1777 insulated stainless steel flex liner
or other approved lining system in offsets
Damper plate is removed or fastened
in open position. Use damper
adapter or seal with non-combustible
material.
*Floor protection in accordance with solid fuel appliance listing
Oakleaf Woodburning Stove
Dry Seasoned Wood Only! Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/1520 3-90-798
Chimney Breach Fireplace Conversion with Combustible Wall
* Floor Protection in Accordance with Solid Fuel Appliance Listing
** Check with your local building codes for clearance.
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Minimum clearance from chimney
connector to uprotected ceiling 15”
Flue liner with required
air space
Listed or approved thimble assembly
1” Clearance for exterior chimney or
2” clearance for interior chimney and
2” clearance for NFPA 211 - type
approved thimbles
Airtight
insulated
clean-out
Damper closed
and sealed with
non-combustible
material
Combustible Floor
Floor Protection*
* Floor protection in accordance with Solid Fuel Appliance Listing
** Check with your local building codes inspector for clearance.
Combustible
Wall
Sheet
Rock
Mantel and Trim Protection
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

Harman Oakleaf Owner's manual

Category
Stoves
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI