  • Hello! I am an AI chatbot trained to assist you with the Harman P68 Installation & Operating Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
3-90-00688R24_06/13
SAVE THESE INSTRUCTIONS.
Installation & Operating Manual
SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD PELLET FUEL-BURNING
ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY
INJURY, OR EVEN DEATH.
FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES.
IF THIS PELLET STOVE IS NOT PROPERLY
INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW
INSTALLATION DIRECTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE
PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT.
TESTED AND LISTED BY OMNI-TEST LABORATORIES; REPORT # 135-S-13c-6.2
TESTED TO; ASTM E 1509-04, ULC S627-00, ULC/ORD C1482-M1990
Model(s):
P68 Freestanding Pellet Stove
NOTICE: SAVE THESE INSTRUCTIONS
Hot glass will cause burns.
• Donottouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
• CAREFULLYSUPERVISEchildreninsameroomas
stove.
• Alertchildrenandadultstohazardsofhightemperatures.
High temperatures may ignite clothing or other
ammable materials.
• Keepclothing,furniture,draperiesandotherammable
materialsaway.
HOT SURFACES!
Glassandothersurfacesarehotduring
operationandcooldown.
WARNING
!
To obtain a French translation of this manual, please
contactyourdealerorvisitwww.harmanstoves.com
Pourobtenirunetraductionfrançaisedecemanuel,s’il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
NOTE
2
P68PelletStove
"PREVENT HOUSE FIRES"
Install and Use Only in Accordance With Manufacturer's Installation and Operation Instructions.
Contact Local Building or Fire Ofcials About Restrictions and Installation Inspection in Your Area.
WARNING : THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,
AND CEILING/ROOF MUST BE MAINTAINED. DO NOT INSTALL IN SLEEPING ROOM.
An outside combustion air inlet must be provided. Refer to Manufacturer’s instructions and local
codes regarding the requirements for passing the exhaust venting system through a combustible
wall or ceiling.
Inspect and Clean Exhaust Venting System Frequently.
Use a 3" or 4" diameter type "L" or "PL" venting system.
Do Not Connect This Unit to a Chimney Flue Serving Another Appliance.
FOR USE WITH WOOD PELLET FUEL OR UP TO 50% CORN / PELLET MIXTURE ONLY.
The Use of Other Fuels May Create an Unsafe Condition.
Input Rating Max: 8 lb. fuel/hr.
U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.3 AMPS, Run 3.2 AMPS
Route Power Cord Away From Unit.
DANGER: Risk of Electrical Shock. Disconnect Power Before Servicing Unit.
For Further Instruction, Refer To Owner's Manual.
Replace glass only with 5mm ceramic available from your dealer.
Keep Viewing and Ash Removal Doors Tightly Closed During Operation.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Tested to / Testé à:
ASTM E1509-04, ULC/ORD-C1482-
M1990, ULC-S627-00
Report #/ Rapport # 135-S-13c-6.2
MINIMUM CLEARANCES TO COMBUSTIBLES/
DISTANCES DE SECURITE PAR RAPPORT AUX
MATERIAUX COMBUSTIBLES:
Back Wall / Entre Mur Arrière 2”/ 51mm 2”/ 51mm
Side Wall / Entre Paroi Latér 20”/ 508mm 14”/ 355mm
CORNER INSTALLATION / EN ANGLE
Walls to Appliance 13”/330mm 9”/228mm
Entre Murs et appareil
Flue Connector/Raccord à la cheminée 3” /76mm
FLOOR PROTECTION / Protection Du Plancher
USA Canada
Sides*/Côtés (A) 6” 200mm
Back**/Arrière (B) 6” 200mm
Front*/Avant (C) 6” 450mm
**Measured from pedestal base in the US ONLY
**Mesuré à partir de la base du socle aux États-Unis uniquement
*Measured from Glass Opening
*Mesurer à partir de la surface de la porte en verre
Floor Protection Must Be a Non-Combustible Material.
Must Also be Place Under Any Horizontal Flue Connector, Extending
2” or 51mm Beyond the Pipe Measurement.
Pour protéger le plancher, il faut sous le pêole un matériau. Qui doit
aussi être placé sous les parties horizontales du tuyau de raccord
à la cheminée et s’étendre à 51mm o 2 po. au-delà de la mesure
du tuyau.
Made in U.S.A. of US and imported parts. / Fabriqué
aux États-Unis-d’Amérique par des pièces d’origine
américaine et pièces importées.
"PREVENTION DES INCENDIES"
Respecter scrupuleusement les instructions du constructeur pour l'installation et les consignes
de fonctionnement. Respecter les règles de sécuritè en vigueur dans votre région.
AVERTISSEMENT POUR MOBILE HOMES: Ne pas installer dans une chambre. ll est imperatif
de prévoir une prise d'alr extérieur. L'intégrité structurale du plancher, du plafond et des murs doit étre
strictement préservée. Se reporter aux instructions du fabricant et aux réglementations spéciques
locales concernant les précautions requises lors de la traversée d'un mur ou d'un plafond.
Contróler et nettoyer fréquemment tout le systeme d'evacuation des fumées conformément aux
recommandations du constructeur. Utiliser des tuyaux <<Spécial granulés>> de Ø76 mm ou
102 mm. Ne pas raccorder ce poéle à un conduit de cheminée déjà utilisé pour un autre appareil.
FONCTIONNE EXCLUSIVEMENT AVEC DES GRANULES DE BOIS.
Appareil de chauffage à granulé type. Consommation maximum: 3.63 kg/h.
US coupure: 115 VAC, 60 Hz, 4.3 amps Démarrer, Exécuter 3.2 AMPS
fonctionnement normal 1.1A. Tenir le cordon d'alimentation à l'écart du poèle.
DANGER: Risque d'électrocution. Débrancher l'appareil avant toute intervention.
Ne remplacer la vitre qu'avec une vitre céramique 5mm de méme qualité disponible
auprès de votre revendeur.
Pour une information plus compléte, se reporter à la notice d'utilisation. Tenir la porte
hermétiquement close durant fonctionnement.
Ne faites pas obstacle l’espace sous le réchauffeur. Toujours fournir un approvisionnement sufsant en air frais
jusqu’au lieu d’installation Appliance
MODEL / Modéle: "P68"
2"(51mm)
14" (355mm) with side shields
20" (508mm) w/out side shields
9”(228mm)
13”(330mm)
9"(228mm)
13”(330mm)
3" min
76mm min
3" min
76mm min
BARCODE LABEL
Date of Manufacture / Date de fabrication:
P.N. 3-90-06806
WITHOUT
SIDE SHIELDS
WITH
SIDE SHIELDS
Sans Écrans
Latéraux Avec Écrans
Latéraux
Fabriqué par: Harman Stove Company 352 Mountain House Road, Halifax PA 17032
US ENVIRONMENTAL PROTECTION AGENCY
This model is exempt from EPA certication under 40 CFR 60.531
by denition [Wood Heater (A) "Air-to-Fuel Ratio"]
Agence Américaine pour la Protection de l’Environnement
Ce modéle est dispensé par EPA certication d’aprés 40 CFR 60.531
par dènition [Appareil á bois (A) << Ratio air/combustible>>]
2012 2013 2014 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Harman P68 Pellet Stove
Label measures: 4-3/8" high X 10-3/4"wide
Black Background with bare metal for print-adhesive backed, metal plate.
AA C
B
USA CANADA
Floor protector
PROTECTiON DE SOL
FLOOR PROTECTiON
008
Serial No.
No de série:
Room Heater Pellet Fuel Burning Type. Also for use in Mobile Homes.
Appareil de chauffage à granulés de bois Utilisable dans des mobile homes.
This pellet burning appliance has been tested and listed for use in Manufactured
Homes in accordance with OAR 814-23-900 through 814-23-909
Rev C
Serial#:
The label shown here is for referrence only. For specic
information on clearances and testing, consult the actual
label on the rear of the P68 fuel hopper.
Thislabelislocatedonthebackoftheunit.
PleasecopytheSerialNumberforfuturereference.
3P68 Pellet Stove 3-90-00688R24_06/13
ImportantNotes/SafetyConcerns 4
Installation     6
Venting     7
AutomaticOperation   14
ManualOperation    17
ESPControl     19
LowDraftVoltageAdjustment  20
RoomSensor    21
Maintenance    22
Troubleshooting    27
FuelSpecications    28
SpecicationsandOptions  29
WiringDiagram    31
PowerFailure/Back-up   33
Warranty     34
ServicePartsListing   36
Table of Contents
Introduction
TheAward-WinningP68PelletStovehasthewidestBTUrangeavailable,givingyou0to68,000BTUwhenyouneedit,
automatically.Theonlythingyouneedtodoissetyourdesiredroomtemperatureandllthehopper.WiththeP68youwill
noticeevenheatthroughoutyourhomeandalevelofconvenienceyouneverthoughtpossible.
TheP68epitomizesthecapabilityofHarmanPelletStoves,takingadvantageofHarman’s20yearsofpelletstovedesign,
technologyandmanufacturing.This68,000BTUstovehasthehighestoutput,smartestcontrols,widestheatingrange,and
minimalmaintenance.TheP68’shugeoutputismanagedbyamicroprocessorthatsensestheroomtemperatureandthe
retemperaturewithtinythermisterprobesandthendeterminesthebestfeedrate.Thisimprovedandsmartercontrolalso
hasadiagnosticportforconnectinganexternaldisplayshowingliveworkingdataforeasiertroubleshooting.
TheplatinumcombinationisHarman’sPatentedFeeder&BurnPot,andESPControlwhichhavebeendevelopedtotheir
higheststate.Thesefeaturesworktogethertoallowamazingheatoutputwithdifferentfuelquality,ashcontentandmoisture.
For Your Safety:Wheninstallingasolidfuelappliance,itis
also recommended to install Smoke and Carbon Monoxide
Detectorsoneverylevelofthehouse.Duringtheinitialring
of the appliance, some smoke or odor may occur due to
paintcuring.Youmaywanttokeepsomewindowsopenfor
ventilationduringtherstfewhoursofburningtopreventsmoke
detector activation. Test your smoke and carbon monoxide
detectorsregularly.
Pleasereadthisentiremanualbeforeinstallationanduseof
thispelletfuel-burningroomheater.Failuretofollowthese
instructionscouldresultinpropertydamage,bodilyinjury,
orevendeath.
352MountainHouseRoad
Halifax,PA17032
= Contains updated information
4
P68 Pellet Stove
3-90-00688R24_06/13
DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
Mobile home installation should be done in
accordance with the Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
CAUTION
THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED.
CAUTION
KEEP COMBUSTIBLE MATERIALS (SUCH AS
GRASS, LEAVES, ETC.) AT LEAST 3 FEET AWAY
FROM THE FLUE OUTLET ON THE OUTSIDE OF
THE BUILDING.
IMPORTANT NOTES
Installation and repair of this Harman stove
should be done by a qualied service person. We
recommend that the stove be inspected before
use and at least annually by a qualied service
person. Periodic cleaning is required throughout
the heating season and at the end of each winter
for the stove to work efciently. See cleaning
instructions on page 23.
Mobile/Manufactured Home Standards Do
Not Allow Installation In Rooms Designated
For Sleeping.
WARNING
Fuel
TheP68isapprovedforusewithwoodpelletsandfora
mixtureofshelledcornandwoodpellets.Seethecorn
mixtureaddendumonpage33ofthismanual.
Storefuelinadryarea,wellawayfromtheappliance.
Remember,cornisafoodsourceandwillattractbugs
andotherpests.Ifusingcornforburning,keepitina
sealedcontaineroutsideyourhome.
DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
INSPECT AND CLEAN EXHAUST VENTING
SYSTEM FREQUENTLY.
CAUTION
HOT WHILE IN OPERATION. KEEP
CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS.
CAUTION
DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPTHA OR
ENGINE OIL.
WARNING
Burning fuels other then what is specifed
could result in damage to the unit and/or its
components.
5P68 Pellet Stove 3-90-00688R24_06/13
Assembly and Installation
Unpacking
TheP68is bolted(1/4x1"hexheadbolts) to theskidto
preventmovementduringshipping.
Tofreethestovefromtheskidyoumustremovethehold-
downboltsintherearofthepedestalbase.
Rear cover panels
Therearcoverpanelsneedremovedfromthestovetomake
iteasiertogetatthehold-downbolts.
Therearcoverpanelsmustbereinstalledoncetheinstallation
iscomplete.Thesepanelsare to gaurdfrom contact with
hotandmovingparts.Toreducetheriskofelectricshock,
disconnectpowerbeforeremovingtherearcovers.
Firebrick
Installtherebrickverticallyontheanglebracketabovethe
burnpot.
Flame Guide
Installthecastironameguideontopoftheburnpot.Make
surethattheameguideisfullyseatedontheverticalsides
oftheburnpotandthatthebackoftheguiderestsagainst
thebodyofthestove.
INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED
BY THE VENTING MANUFACTURER.  Most pellet vent
requires a minimum of 3" of clearance to combustible
materials.
SpringWasher
1. Removewoodhandle,springwasher,andsockethead
capscrew¼-20x2-1/4"fromhardwarepack.
2. Installspringwasherandwoodhandleontosockethead
capscrewasshowning.2andthreadontolatchonfront
door.
3. Tightenusinga3/16"hexkeywrench.
WoodHandle 1/4-20x2-1/4
socket-headscrew
Door Handle Installation
Fig. 2
Rear Cover
Panels
Shipping Bolts
Note: These same holes
are used for securing the
stove in mobile home
installation.
Fig. 1
Door Hinge Retainers:
Thereare two 3/8” retainer clipsthat are in the hardware
packsentwiththestove.Theyaretobeinstalledontothe
loaddoorhingepinsafterthetrimhasbeeninstalledand
thedoorismountedontothestovebodyandreadyforuse.
Toremovetheloaddoorforanyserviceortochangethetrim,
theretainerclipsmustberemovedandmaybedamaged.
ReplacementscanbeorderedthroughyourHarmanDealer
(Part #3-31-94807031) or a 3/8” retainer clip may be
purchasedatyourlocalhardwarestore.
The 3/8" retainer
clips will go on
each hinge pin,
below the hinge.
6
P68 Pellet Stove
3-90-00688R24_06/13
Installing
Placethestoveonanoncombustibletypeoororoorprotector
thatextendsaminimumof6inches(152mm)tothefrontofthe
loaddooropening,6inches(152mm)tothesidesofthedoor
opening, and 6 inches to the rear. Floor protection must also
extend2inches(51mm)beyondeachsideofanyhorizontalue
pipe.The minimum oor protectormaterialis20 gauge sheet
metal. Other oor protector materials are ceramic tile, stone,
brick,etc.
NOTE for Canadian installation only: Per ULC-S627-00,
If installed on a combustible floor, the need to provide a
noncombustible oor protector covering the area beneath the
space heater andextendingatleast17.72"(450mm)onthering
sideandatleast7.87"(200mm)ontheothersides.
In Canada, you may follow smaller U.S. oor protection
requirements ONLY if the user agrees to completely shut-
down the appliance, and allow it to cool to where all re is
extinguished and the combustion blower and its indicator
light shuts off, prior to opening the rebox door or ash door.
Placethestoveawayfromcombustiblewallsatleastasfaras
showninFigures3and4.Pleasenotethedifferenceinsidewall
clearancewithandwithoutsideshields.
Notethattheclearancesshownareminimumforsafetybutdonot
leavemuchroomforaccesswhencleaningorservicing.Please
takethisintoaccountwhenplacingthestove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect the
circuitboard.)Alsobesurethatthepolarityoftheoutletthatthe
stoveispluggedintoiscorrect.
Prior to installing the ue pipe, connect a draft meter. (The
draftmetermusthaveaminimumrangeof0-.5")Recordthe
rstreading.Connectuepipetostoveandbesurealldoors
andwindowsinthehomeareclosed.Recordtheseconddraft
reading_______.Ifthesecondreadingismorethan.05"lower
thantherstreading,checkforpossiblerestrictionsortheneed
foroutsideair(seepage10).Formoreinformationonthedraft
testprocedure,refertoPage21.
Mobile Home Installation
Wheninstallingthisunitinamobilehome,severalrequirements
mustbefollowed:
1.Theunitmustbeboltedtotheoor.Thiscanbedonewith1/4"
lagscrewsthroughthe2holesinthebaseplate.
2.Theunitmustalsobeconnectedtooutsideair.Seepage10.
3.Floorprotectionandclearancesmustbefollowedasshown.
4.Unitmustbegroundedtothemetalframeofthemobilehome.
5.Besuretofollowtheventmanufacturer'sguidelinestoprovide
for a sufcient vapor barrier where the ue penetrates the
outside.
6.Thetopsectionofanychimneyorventingmustberemovable
toaheightof13'(3.9M)toallowfortransport.
7.
Thefactory-builtchimneymustconformtoCAN/ULC-S629,
Standardfor650°CFactory-BuiltChimneys.
CAUTION: This appliance must be vented to the outside.
Clothingandotherammablematerialsshouldnotbeplacedon
ornearthisunit.
Installation
L
J
Floor Protection
Requirements US Canada
Sides
Rear
6" 200mm
6" 200mm
KFront 6" 450mm
Fig. 3
9"(228mm)With Side Shields
13"(330mm) Without Side Shields
Fig. 4
2"(51mm)
36"(914mm)
14" (355mm) with
side shields
20" (508mm)
without side shields
14" (355mm)
20" (508mm)
Minimum size rectangular oor protection (USA) is
285/16"DeepBy243/4"Wide.
* Floor protection dimensions for the front and sides
are measured from the appliance door opening in
The United States. In Canada, the side dimension is
measuredfromthewidestpartoftheappliance.
J
USA K
L
J
CANADA
NOTE:
Measurement"L"
ismeasuredfrom
thepedestalbase
intheUSONLY
NOTE:
Measurement"K"
ismeasuredfrom
theglassinthe
USONLY
Floor protector
THE STRUCTURAL INTEGRITY OF THE
MANUFACTURED HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
WARNING
DO NOT INSTALL IN SLEEPING ROOM.
9"(228mm)-
13"(330mm)
9"(228mm)-
13"(330mm)
Alternate floor protector
dimension may be used
as long as they satisfy the
measurement requirements
shown below.
Minumum size oor protection
for a corner installation is 36"
x 36". Clearance shown as
9" with optional side shields
installed.
7P68 Pellet Stove 3-90-00688R24_06/13
V=Vent Terminal A=Air Supply Inlet =Area where termination is mot permitted
Door
Sidewalk
Fixed
Closed
Openable
Openable Fixed
Closed
Inside Corner
Detail
Porch or
Openable
Deck
or Fixed
Venting
Requirements for Terminating the Venting
WARNING:Ventingterminalsmustnotberecessedintoa
wallorsiding.
NOTE:OnlyPLventpipewallpass-throughsandrestops
shouldbeusedwhenventingthroughcombustiblematerials.
NOTE:Always take into consideration the effects of the
prevailing wind direction or other wind currents that may
causeyashand/orsmokewhenplacingtheterminationvent.
In addition, the following must be observed:
A. Theclearanceabovegrademustbeaminimumof18".
B. Theclearancetoawindowordoorthatmaybeopened
must be a minimum of 48" to the side, 48" below the
window/door, and 12" above the window/door.(with
outside air installed, 18”)
C.A 12" clearance to a permanently closed window is
recommendedtopreventcondensationonthewindow.
D.Theverticalclearancetoaventilatedsoftlocatedabove
theterminalwithinahorizontaldistanceof2feet(60cm)
fromthecenter-lineoftheterminalmustbeaminimum
of18".
E. Theclearancetoanunventilatedsoftmustbeaminimum
of12".
F. Theclearancetoanoutsidecorneris11"fromcenterof
pipe.
G.Theclearancetoaninsidecorneris12".
H.Aventmustnotbeinstalledwithin3feet(90cm)above
agasmeter/regulatorassemblywhenmeasuredfromthe
horizontalcenter-lineoftheregulator.
I. Theclearancetoserviceregulatorventoutletmustbea
minimumof6feet.
J. Theclearancetoanon-mechanicalairsupplyinlettothe
buildingorthecombustionairinlettoanyotherappliance
mustbeaminimumof48”.
K. Theclearancetoamechanicalairsupplyinletmustbea
minimumof10feet.
(with outside air installed, 6 feet )
L. The clearance above a paved sidewalk or a paved
drivewaylocatedonpublicpropertymustbeaminimum
of7feet.
M.Theclearanceunderaveranda,porch,deckorbalcony
mustbeaminimumof12inches. (See B.)
NOTE: The clearance to vegetation and other exterior
combustibles such as mulch is 36” as measured from the
centeroftheoutletorcap.This36”radiuscontinuestograde
oraminimumof7feetbelowtheoutlet.
Certain Canadian and or  Local codes or regulations may
requiredifferentclearances.
Aventshallnotterminatedirectlyaboveaside-walkorpaved
drivewaywhichislocatedbetweentwosinglefamilydwellings
andservesbothdwellings.
Onlypermittedifveranda,porch,deck,orbalconyisfullyopen
onaminimumof2sidesbeneaththeoor.
NOTE: Where passage through a wall, or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365. (if in Canada)
8
P68 Pellet Stove
3-90-00688R24_06/13
Venting
A combustion blower is used to extract the combustion
gasesfromtherebox.Thiscausesanegativepressurein
thereboxandapositivepressureintheventingsystemas
showninFig.7.Thelongertheventpipeandmoreelbows
usedinthesystem,thegreatertheowresistance.Because
ofthesefactswerecommendusingasfewelbowsaspossible
and15feetorless ofventpipe.Themaximumhorizontal
runshouldnotexceed48".Ifmorethan15feetofpipeis
needed,theinteriordiametershouldbeincreasedfrom3"
to4"becausealargerpipecauseslessowresistance.Be
sure to use approved pellet vent pipe wall and ceiling
pass-through ttings to go through combustible walls
and ceilings. All joints for connector pipe must be
fastened with a minimum of three screws. Follow pellet
vent manufacturer instructions for properly securing
each pellet vent joint. The pellet starting collar must be
secured to the unit's ue collar.
NOTE: Simpson DuraVent PelletVent Pro Harman Adapter
Part #3PVP-ADHB and PelletVent Pro Harman Adapter
Increaser Part #3PVP-X4ADHB are highly recommended
to be installed on the starter collar to insure a proper
pipe connection to the unit.
Venting
IMPORTANT NOTICE
Approved3"or4"PelletVentPipeSuchAs,Type"PL",
MustBeUsed.
+
+
-
Fig. 7
Vent Pipe
Pelletventingpipe(knownasPLvent)isconstructedoftwo
layerswithairspacebetweenthelayers.Thisairspaceacts
asaninsulatorandreducestheoutsidesurfacetemperature
toallowaclearancetocombustiblesof1to3inches.The
sections of pipe lock together to form an air tight seal in
mostcases.However,insomecasesaperfectsealisnot
achieved.ForthisreasonandthefactthattheP68operates
withapositiveventpressurewe specify that the joints also
be sealed with high temp (RTV) silicone. Aluminumtape
canalsobeusedforanyjointthatis1ft.ormorefromthe
outletofthestove.
Avoiding Smoke and Odors
Negative Pressure, Shut-down, and Power Failure:
To reduce the probability of back-drafting or burn-back in
the pellet burning appliance during power failure or shut-
down conditions, the stove must be able to draft naturally
withoutexhaustbloweroperation.Negativepressureinthe
housewillresistthisnaturaldraftifnotaccountedforinthe
pelletapplianceinstallation.
Heatrisesinthehouseandleaksoutatupperlevels.Thisair
mustbereplacedwithcoldairfromoutdoors,whichowsinto
lowerlevelsofthehouse.Ventsandchimneysintobasements
andlowerlevelsofthehousecanbecometheconduitforair
supply,andreverseundertheseconditions.
Outside Air:
Hearth & Home Technologies strongly recommends
attaching outside air in all installations, especially lower
level and main oor locations.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
A CHIMNEY CONNECTOR MAY NOT PASS THROUGH
AN ATTIC OR ROOF SPACE, CLOSET OR SIMILAR
CONCEALED SPACE, FLOOR , OR CEILING. REFERENCE
LOCAL BUILDING CODES FOR DETAILS.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER
CAUTION
DO NOT USE MAKESHIFT COMPROMISES WHEN
INSTALLING THIS APPLIANCE. DAMAGE AND/OR
INJURY MAY RESULT.
= Positive Static Pressure
= Negative Static Pressure
+
-
9P68 Pellet Stove 3-90-00688R24_06/13
Venting
Outside air ex pipe
goes here.
Inlet Cover part#
1-10-08542
Flex pipe part#
1-00-08543 (25')
Direct Vent Wall Passthrough Kit
(part #1-00-677077)
Pernationalbuildingcodes,considerationmustbegivento
combustionairsupplytoallcombustionappliances.Failure
tosupplyadequatecombustionairforallappliancedemands,
mayleadtoback-draftingofthoseandotherappliances.
Whentheapplianceisside-wallvented:Theairintakeisbest
locatedonthesameexteriorwallastheexhaustventoutlet
andlocatedloweronthewallthantheexhaustventoutlet.
When the appliance is roof vented: The air intake is best
locatedontheexteriorwallorientedtowardstheprevailing
winddirectionduringtheheatingseason.
Theoutsideairconnectionwillsupplythedemandsofthe
pellet appliance, but consideration must be given to the
totalhousedemand.House demand may consumesome
airneededforthestove,especiallyduringapowerfailure.It
maybenecessarytoaddadditionalventilationtothespacein
whichthepelletapplianceislocated.Consultwithyourlocal
HVACprofessionaltodeterminetheventilationdemandsfor
yourhouse.
Toinstalloutsideairuse23/8"I.D.non-combustibleexpipe.
Thereisabreak-awayholeontherearpaneloftheP68stove
whichmustberemovedbeforeconnectingtheexpipe.The
pipeshouldberunoutsideandterminatetothesideorbelow
theventpipeoutletsotheueoutletismorethan12"from
theinletcover.Themaximumlengthrunofthispipeis15
feet.Ifalongerrunisneededthesizemustbeincreasedto
3".Inletcover,partnumber1-10-08542shouldbeusedto
keepbirds,rodents,etc.outofthepipe.
You may choose to use the optional Direct Vent Wall
PassthroughKit(part#1-00-677077)whichincorporatesthe
ventingpassthroughandoutsideairinletintoonecomponent.
NOTICE:InCanada,ULC-S627 requires thatalloutdoor-
airedspaceheatersbesecuredtothestructure.
Vent Congurations:
Toreduceprobabilityofreversedraftingduringshut-downconditions,Hearth&HomeTechnologiesstronglyrecommends:
• Installingthepelletventwithaminimumverticalrunofvefeet,preferablyterminatingabovetheroofline.
• Installingtheoutsideairintakeatleastfourfeetbelowtheventtermination.
Topreventsootdamagetoexteriorwallsofthehouseandtopreventre-entryofsootorashintothehouse:
• Maintainspeciedclearancestowindows,doors,andairinlets,includingairconditioners.
• Ventsshouldnotbeplacedbelowventilatedsofts.Runtheventabovetheroof.
• Avoidventingintoalcovelocations.
• Ventsshouldnotterminateunderoverhangs,decksorontocoveredporches.
• Maintainminimumclearanceof12inchesfromtheventterminationtotheexteriorwall.Ifyouseedepositsdeveloping
onthewall,youmayneedtoextendthisdistancetoaccommodateyourinstallationconditions.
Hearth & Home Technologies assumes no responsibility for, nor does the warranty extend to, smoke damage caused
by reverse drafting of pellet appliances under shut-down or power failure conditions.
10
P68 Pellet Stove
3-90-00688R24_06/13
#2 Preferred method
This method also provides excellent venting for normal
operationbutrequiresthestovetobeinstalledfartherfrom
thewall.Theverticalportionoftheventshouldbethreeto
vefeethighandatleastthreeinchesfromacombustible
wall.Thisverticalsectionwillprovidenaturaldraftintheevent
ofapowerfailure.
If the stove is installed below grade be sure the vent
termination is at least 18" above grade. The outlet must also
be 1 foot from the house/building.
Note: Do not place joints within wall pass-throughs.
#1 Preferred method
Thismethodprovidesexcellentventingfornormaloperation
andallowsthestovetobeinstalledclosesttothewall.Two
inches from the wall is safe; however, four inches allows
betteraccesstoremovetherearpanel.Theverticalportionof
theventshouldbethreetovefeethigh.Thisverticalsection
willhelpprovidenaturaldraftintheeventofapowerfailure.
Note: Do not place joints within wall pass-throughs.
Venting
36" min
clearance to any
combustible
material
12" min. wall to outlet
CAUTION
Keep combustible materials (such as grass, leaves,
etc.) at least 3 feet away from the ue outlet on the
outside of the building
Fig. 8
3 ft.
to
combustibles
3 ft.
to combustibles
Fig. 9
3 ft.
to
combustibles
3 ft.
to combustibles
11 P68 Pellet Stove 3-90-00688R24_06/13
#4 Installing into an existing chimney
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.Ifthechimneyconditionisquestionable*you
maywanttoinstallalinerasinmethod#7.
*The chimney should be inspected and cleaned before
installingyourstove.Ifyoudiscoverthatthechimneydoes
nothaveaclaytilelinerorhascracksorakingofthetile
liner you will need to install a stainless steel liner within
thechimney.Inmostcasestheinsidediameterofthisliner
shouldbe4".Eitherexibleorrigidlinermaybeusedfor
thispurpose.RefertoMethod6&7.
Besuretodesigntheventingsothatitcanbeeasilycleaned.
#5 Installing into an existing replace chimney
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.Ifthechimneyconditionisquestionable*you
maywanttoinstallalinerasinmethod#6.
*The chimney should be inspected and cleaned before
installingyourstove.Ifyoudiscoverthatthechimneydoes
nothaveaclaytilelinerorhascracksorakingofthetile
liner you will need to install a stainless steel liner within
thechimney.Inmostcasestheinsidediameterofthisliner
shouldbe4".Eitherexibleorrigidlinermaybeusedfor
thispurpose.RefertoFig.6&7.
The chimney should be sealed at the damper using a
steel plate. Kaowool, mineral wool or an equivalent non-
combustibleinsulationisrecommendedtobeinstalledontop
ofthesealingplatetoreducethepossibilityofcondensation.
The connector pipe should extend through the smoke
chambertothebaseorintotherstuetile.
Besuretodesigntheventingsothatitcanbeeasilycleaned.
Venting
Fig. 10
Fig. 11
WARNING!
THE CHIMNEY AND CONNECTOR MUST BE
MAINTAINED IN GOOD CONDITION AND KEPT CLEAN.
THE CHIMNEY MUST BE OF A TYPE SUITABLE FOR
SOLID-FUEL BURNING.
12
P68 Pellet Stove
3-90-00688R24_06/13
#6 Installing into an existing replace chimney
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.
InsomeplacesintheUSandCanadaitisrequiredthatthe
ventpipeextendallthewaytothetopofthechimney.
Inthismethodacapshouldalsobeinstalledonthechimney
tokeepoutrain.Besuretouseapprovedpelletventpipe
ttings. Seal pipe joints with silicone or aluminum tape in
additiontothesealingsystemusedbythemanufacturer.Pipe
sizeshouldbeincreasedto4"usingthismethod.
Chimney must be of a type suitable for use with solid
fuel.
#7 Installing into an existing chimney
Thismethodprovidesexcellentventingfornormaloperation.
This method also provides natural draft in the event of a
powerfailure.
InsomeplacesintheUSandCanadaitisrequiredthatthe
ventpipeextendallthewaytothetopofthechimney.The
pipeorlinerinsidethechimneyshouldbe4"diameter.
Inthismethodacapshouldalsobeinstalledonthechimney
tokeepoutrain.
Chimney must be of a type suitable for use with solid
fuel.
Venting
Fig. 12
Fig. 13
WARNING!
THE CHIMNEY AND CONNECTOR MUST BE
MAINTAINED IN GOOD CONDITION AND KEPT CLEAN.
13 P68 Pellet Stove 3-90-00688R24_06/13
#8 Installing through the ceiling
Through the ceiling vent, follow PL vent manufacturers
recommendationswhenusingwallandceilingpassthroughs.
Note: Do not place joints within wall pass-throughs.
Minimum flue vent
conguration
It is recommended that outside
airbeinstalledwiththisventing
conguration to reduce smoke
andcreosotesmellintheroomin
theeventofpowerfailure.
Min. above ground level
12"
Venting
Fig. 15
Fig. 14
PL vent manufacturer's
restop spacer and
support
(See Page 7 for
corner installation
clearances)
Storm collar
Flashing
3"min. 3"min.
12"min.
3"min.
3"min.
No insulation or
other combustible
materials are allowed
within 3" of the pellet
vent pipe. Unless
specied by the pipe
manufacturer
12"
min. wall to outlet
36"
min. clearance to any
combustable material
Fig. 16
14
P68 Pellet Stove
3-90-00688R24_06/13
AUTOMATIC IGNITION/OPERATION
TheP68isafullyautomaticstovethatfeaturestwooperating
modes;Stove Temperature ModeandRoom Temperature
Mode.InStoveTemperatureMode,youselectaburnrate
andthestovewillremainatthesameburnrateregardless
oftheroomtemperature.
IntheRoomTemperatureModethestoveconstantlymonitors
thetemperatureintheroomandadjuststhesizeofthere
andtheheatoutputofthestovesothattheroomiskeptat
aconstanttemperature.Roommode,intheAUTOposition,
hastheaddedadvantageofturningthestoveoffifnoheat
isrequiredandturningthestoveonagainwhentheroom
temperaturedropsbelowyourdesiredroomtemperature.
Room Temperature Mode
Most consumers use the stove in the Room Temperature
Modebecauseitistheeasiestandmost efcient method
ofkeepingtheroomatagiventemperature.IntheRoom
Temperature Mode, the Room Sensing Probe constantly
monitorsroomtemperature.Astheweatherchangesoutside
andyourhomeneedsvarying amountsofheattobeata
desiredtemperature, thestove willautomatically increase
size and heat output of the re so that a constant even
temperatureismaintained.Iftheweatherwarmsupandno
heatisrequiredthestovewillgraduallyshutdown.Whenthe
housecoolsdownthestovewillautomaticallybringtheroom
temperaturetotheprecisetemperatureyoudesire.
IntheRoomTemperatureModeyoucanselecteitherAuto
or Manual modes for the igniter using the igniter toggle
switch.WhenthetoggleswitchisintheAutopositionthe
igniterlocatedinsidetheburnpotisreadytoautomatically
lighttherewhenrequired.Whenthetoggleswitchsettothe
Manualpositionthestovecanbelitmanuallywitheitheragel
orawaxtyperestarter.(seelightinginstructionsonpage
18.)WiththeignitertoggleswitchsetintheManualposition
thestovewillautomaticallyadjustheatoutput,butthestove
willnotautomaticallyshutdownifnoheatisrequired.Instead
itwillgotoitslowestsettingandremainthere.TheManual
positionontheignitertoggleswitchletsyoulightthestove
manually,shouldtheigniterfailforanyreason.Secondlyif
youareusingtheHarmanbatterybackupsystemtheManual
settingwillpreventthestovefromturningoffandonduring
apowerfailure,whichwoulddrainthebackupbattery,and
possiblycausedamagetotheback-uporthestove.
IntheRoomTemperatureMode,thedistributionblowerspeed
canbeincreasedordecreasedbyadjustingtheRoomTemp/
Off/StoveTempdialbetweenLandH.Asoutputofthestove
increases,thespeedoftheblowerwillincreaseautomatically
toinsurethatmoreheatistransferredoutintotheroom.The
distributionblowerwillshutoffastheroomreachestheset
temperature,thiswillpreventoverheatingoftheroom.
Room Temperature Mode: Thissetting,seeabove,willproduce
aroomtemperatureof70degreeswiththedistributionblowerat
mediumspeed.
Room Temperature Mode
KEEP APPLIANCE DOORS CLOSED WHILE IN
OPERATION. MAINTAIN ALL SEALS IN GOOD CONDITION.
15 P68 Pellet Stove 3-90-00688R24_06/13
AUTOMATIC IGNITION/OPERATION
The setting above will produce continuous maximum heat output
with the distribution blower at full speed.
Stove Temperature Mode
The setting above will produce continuous medium heat output
with the distribution blower at low speed.
Shut Down Procedure
Thebestwaytoshutdownthestoveissimplyletitrunoutof
pellets.Thestovewillshutdownautomatically.Alternatively,
youcanturntheModeSelectorto“off”.Thiswillcausethe
retograduallydiedownandgoout.Therewillnotgo
out immediately and may take more than an hour to fully
shutdown.
Ifthestoveislefttorunoutoffuel,youmaygeta6blink
statuslight.Ifthishappenssimplyresetthecontrolboardby
turningthemodeselectortoOFFandbackON.
Stove Temperature Mode
IntheStoveTemperatureModeandwiththeignitertoggle
switchintheAutoposition,thestovewilllightautomatically
andcanbeadjustedtothedesiredsettingusingthesame
temperaturecontroldialasisusedintheRoomTemperature
Mode. The heat output and fuel consumption will remain
constantregardlessofroomtemperature.Thesettingsfrom
1to7ontheinnerringofthedialprovideforrelativeheat
outputsettingswith1beinglowand7beingthemaximum.
InStoveTemperatureMode,thestovewillnotautomatically
shutoffunlessthestoverunsoutoffueloristurnedoff.
Neverpulltheplugtoshutdownthestove.Thiswillstopthe
combustionblowerandsmokewillescapethroughwindow
anddoorgaskets.
Whentheignitertoggleswitchissettomanualinthismode,
thedistributionblowerwillnotturnonwithatemperaturedial
settingfrom1to5.Theadvantageofthismodeistoallow
theoperatortohavealargeviewingrewithoutblowingextra
heatintotheroom.
During manual operation, with the temperature dial set
at #4 or less, the distribution fan will not operate.A #4
on the temperature dial and a #5 on the feed adjuster is
approximately80%output.Itisnotnecessarytooperatethe
distributionblowerbelowthispoint.Therefore,thecontrol
allowsahigherburnrate(alargerviewingre)withoutan
excessofhotairblowingintotheroom.
AnexampleofwhentousetheManualStoveTemperature
Modeisifyouwanttowatcha large re and the room is
alreadyuptotemperature.TheStoveTemperatureMode
allows you to have a larger re and a lower sound level,
withoutthedistributionblower.
NOTE: During the use of this mode, if you keep increasing
the temperature dial setting to increase the re size, the
distribution blower will automatically come on when the
ESP Temperature reaches 350o F, or 81% output.
Feed Adjuster Knob
FormostpremiumgradepelletfuelstheFeedAdjusterKnob
shouldbesetat4.Ifhigherashfuelsareusedthesetting
should be increased to 5 or 6. Also higher settings are
requiredifyouwouldliketogetthemaximumheatoutputfrom
thestove.Atthemaximumburnrate(withthetemperature
dialon7/90°andthefeedadjusterat6)thereshouldbe1"or
moreofashonthefrontoftheburnpot.Ifthereislessthan
1"ofash,turnthefeedadjusterknobdowntoalowersetting.
16
P68 Pellet Stove
3-90-00688R24_06/13
AUTOMATIC START UP
Helpful Hints
1. Fines are small pieces of broken pellets (sawdust). Fines do not
ow easily and often build up on the hopper funnel bottom angles.
You can push these nes into the feeder opening and then ll the
hopper with pellets. As the system works, they will be burned. Or
you can clean them out before lling the hopper.
2. The "TEST" cycle will operate the feeder motor for exactly one
minute. Turning to "TEST" again and again may purge too much
fuel into the burn pot causing excessive smoke on start-up.
3. The rebox low pressure switch will not allow the auger motor
or the igniter element to operate if the view door or the ash pan
door are open.
4. Adjust Feed Rate. If this is your rst re or you are trying different
pellets, set the feed adjuster to #4, Fig. 17. This is a conservative
number and will probably need to be increased. After you know a
feed rate setting that works well, use that setting. Remember, if your
feed rate is too high you may waste fuel.
5. This is usually a weekly maintenance procedure. Cleaning the
burn pot with the scraper with a small amount of new fuel in the
bottom is not a problem. First, scrape the ashes on the front of the
burn pot into the ash pan. Then, scrape the top surface of the burn
pot downward into the base of the burn pot. When the stove is
ignited these scrapings will be pushed out by the feeder and burned.
6. The ash pan can hold the ashes from approximately 1 ton of
premium fuel. This means the ashes will only need to be emptied
a few times a year.
7. Setting the feed adjuster # for maximum burn: With the unit
burning in "AUTO", turn to "Stove Mode" and put the fan on "H".
Set the Temperature Dial to #7. Allow the unit to burn for about 30
minutes and check ash on front of burn pot. Fig. 18. If the ash line
is larger than 1", turn the feed adjuster from #4 to #5. Allow another
30 minutes of burn time and check again. If , at #6 setting, a 1" or
less ash bed is not obtainable, it is not a problem. The 1" ash bed
is only at maximum burn rate and at most normal settings the ash
bed will be larger.
Fig. 17 SeeHint #7.
Fig. 18
1"
Flame Guide
Igniter Switch to "AUTO" (up position)
Makesuretheunitispluggedintoa120VAC,60HZelectrical
source.Thepowerlightshouldbetheonlylightlit.
To avoid unwanted smoke, be sure there is no fuel or
combustibles in the ash pan prior to lighting.
1. Turn Mode Selector to "OFF".
2. Fill hopperwithpellets.
3. Clean burn pot withscraper,ifnecessary.
4. If starting after an empty hopper, turn Feed Adjuster
to "TEST" (forone60secondcycle).Thiswillfeedpellets
intotheaugertubeandalsoallowyoutocheckthemotors
foroperation.NOTE: The auger motor will not operate
with the view door or ash pan door open.
5. Turn Feed Adjuster to #4.
6. Flip the Igniter Switch up intothe"AUTO"position.
7. Turn the Temperature Dial todesiredroomtemperature.
8. Turn Mode Selector to Room Temperature or Stove
Temperature.
9. Fill hopper withpelletsandremove ashesasrequired.
CAUTION
HOT WHILE IN OPERATION. KEEP CHILDREN,
CLOTHINGANDFURNITUREAWAY.
CONTACTMAYCAUSESKINBURNS.
CAUTION
KEEPHOPPERLID,FIREDOOR,ANDASHDRAWER
PROPERLY CLOSED WHENAPPLIANCE IS IN
OPERATION.
CAUTION
DO NOT USE CHEMICALS OR FLUIDS TO START
THE FIRE. FOR EXAMPLE: NEVER USE GASOLINE,
GASOLINE-TYPE LANTERN FUEL, KEROSENE,
CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR "FRESHEN UP" A FIRE IN THIS HEATER.
KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE
HEATER WHILE IT IS IN USE.
Starting First Fire
17 P68 Pellet Stove 3-90-00688R24_06/13
TheP68PelletStoveiscapableofmanualoperation.Thisalsoallowstheoperatortomanually
controloperationduringanemergency(i.e.igniterfailure,orwhenusingcertaingenerators
orotherauxilliarypowersource.)
Theunitcanbeswitchedbetween"AUTO"and"MANUAL"atanytimeduringoperation.
Igniter Switch to "MANUAL"
Room Temperature Mode
Therewillhavetobelitwithstartinggelandamatch,or
started automatically, see "Automatic Operation" on Page
15.Turnto"Manual"positionaftertheignitioncyclebegins.
Thedifferencebetween"AUTO"RoomTemperatureMode
and"Manual"RoomTemperatureModeisthattherewill
notgooutastheroomtemperaturegoesabovethecontrol
boardsetting.Theunitcanonlygotolowburnandwillremain
thereuntil it runs out offuel or untilmore heat is needed
andthefeedrateincreases.Feedrateadjustmentsanddial
settingsarethesameas"AUTO"settings.Theblowerwill
shutoffcompletelyifthetemperatureontheESPistoolow.
Igniter Switch to "MANUAL"
Stove Temperature Mode
Theadvantageofthismodeistoallowtheoperatortohave
alargeviewingrewithoutblowingextraheatintotheroom.
Duringoperation,withthetemperaturedialsetat#4orless,
thedistributionfanwillnotoperate.A#4onthetemperature
dial and a #5 on the feed adjuster is approximately 80%
output.Itisnotnecessarytooperatethedistributionblower
belowthispoint.Thiscontrolsettingallowsahigherburnrate
(alargerviewingre)withoutanexcessofhotairblowing
intotheroom.
AnexampleofwhentousetheManualStoveTemperature
Modeisifyouwanttowatcha large re and the roomis
alreadyuptotemperature.TheStoveTemperatureMode
allows you to have a larger re and a lower sound level,
withoutthedistributionblower.
NOTE: During the use of this mode, if you keep increasing
the temperature dial setting to increase the re size, the
distribution blower will automatically come on when the
ESP Temperature reaches 350o F, or 81% output.
MANUAL IGNITION/OPERATION
Room Temperature Mode: This
setting, see below, will produce a
room temperature of 70 degrees
with the distribution blower at
medium speed.
This setting will produce a large viewing re without a
distribution blower operating.
Manual Stove Temperature Mode
18
P68 Pellet Stove
3-90-00688R24_06/13
MANUAL START UP
Helpful Hints
1. Fines are small pieces of broken pellets (sawdust). Fines do not
ow easily and often build up on the hopper funnel bottom angles.
You can push these nes into the feeder opening and then ll the
hopper with pellets. As the system works, they will be burned. Or
you can clean them out before lling the hopper.As the system
works, they will be burned.
2. The "TEST" cycle will operate the feeder motor for exactly one
minute. Turning to "TEST" again and again may purge too much
fuel into the burn pot causing excessive smoke on start-up.
3. The rebox low pressure switch will not allow the auger motor
or the igniter element to operate if the view door or the ash pan
door are open.
4. Adjust Feed Rate. If this is your rst re or you are trying different
pellets, set the feed adjuster to #4, Fig. 19. This is a conservative
number and will probably need to be increased. After you know a
feed rate setting that works well, use that setting. Remember, if your
feed rate is too high you may waste fuel.
5. This is usually a weekly maintenance procedure. Cleaning the
burn pot with the scraper with a small amount of new fuel in the
bottom is not a problem. First, scrape the ashes on the front of the
burn pot into the ash pan. Then, scrape the top surface of the burn
pot downward into the base of the burn pot. When the stove is
ignited these scrapings will be pushed out by the feeder and burned.
6. The ash pan can hold the ashes from approximately 1 ton of
premium fuel. This means the ashes will only need to be emptied
a few times a year.
7. Setting the feed adjuster # for maximum burn: With the unit
burning in "AUTO", turn to "Stove Mode" and put the fan on "H".
Set the Temperature Dial to #7. Allow the unit to burn for about 30
minutes and check ash on front of burn pot. Fig. 21. If the ash line
is larger than 1", turn the feed adjuster from #3 to #4. Allow another
30 minutes of burn time and check again. If , at #6 setting, a 1" or
less ash bed is not obtainable, it is not a problem. The 1" ash bed
is only at maximum burn rate and at most normal settings the ash
bed will be larger.
Fig. 20
Fig. 19
Fig. 21
1"
See Hint #7.
Manual "Cold" Start
CAUTION
DO NOT USE CHEMICALS OR FLUIDS TO START
THE FIRE. FOR EXAMPLE: NEVER USE GASOLINE,
GASOLINE-TYPE LANTERN FUEL, KEROSENE,
CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO
START OR "FRESHEN UP" A FIRE IN THIS HEATER.
KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE
HEATER WHILE IT IS IN USE.
Igniter Switch to "MANUAL"
Makesuretheunitispluggedintoa120VAC,60HZelectrical
source.
IMPORTANT: Toavoidunwantedsmoke,Besurethereis
nofuelorothercombustiblesintheashpanpriortolighting.
Keepalldoorsclosed during operation. Maintain all seals
andgasketsingoodcondition.
Useonlytheburnpot,assuppliedintherebox,tosupport
orcontaintheburningfuel.Nootherformofgrateorrack
ispermitted.
1. Turn FEED ADJUSTER to the desired feed rate.No.4
isgoodformostpellets.
2. Turn the MODE SELECTOR to “OFF” and then to the
desired mode.Thiswillreset thecontrolandstartthe
combustionmotor.
3. Turn the TEMPERATURE DIAL to the desired setting.
4. Clean the burn pot with the scraper, if necessary.
5. Fill the burn pot with pellets, only level with front edge.
(DoNotOverFill).
NOTE: If an automatic ignition was attempted - Be sure
to give the appliance at least 30 minutes of cooling time
before proceeding with these instructions.
6. Add starting gel on top of the pellets.Stirthegelinto
pelletsforfasterlighting.
SEE CAUTION BELOW.Theuse of a startinggel that is
commerciallymarketedforusewithpelletstovesispermitted
ONLYwhenperformingacoldstart.Alsobesuretoperform
theabovestepsinsequencetoensurecombustionblower
operationbeforeapplyingthestartinggel.Followthestarter
manufacturer'sinstructionsforproperapplication.
7. Light the starting gel with a match, and close the door.
Operation will begin when the re reaches the proper
temperature.
8. Fill the hopper with pellets and remove ashes as
required.
19 P68 Pellet Stove 3-90-00688R24_06/13
AUTOMATIC IGNITION ESP CONTROL
Feed adjuster
Sets the maximum feed
rate
Test
Runs all motors at full
speed for one minute
to check operation.
Afterwards, it will simulate
a minimum burn and the
combustion blower will
remain on low.
Distribution Blower
speed adjustment
range.
L = low
H = high
Variable speed anywhere
between L and H; although
as the stove temp. goes up,
so does the low end of the
scale.
Temp dial
Allows you to adjust the room temperature in Room
Temp Mode using the outer scale marked in degrees
Fahrenheit. It also allows you to adjust the stove
temperature while in Stove Temp Mode using the
inner scale marked from 1 to 7.
Mode Selector
Allows you to choose between
Room Temp Mode, Stove Temp
Mode, or OFF. Also allows you
to vary the distribution blower
speed by turning the knob to the
high or low side of each mode.
Power Light
Indicates power to the
control.
Indicates power to the
feed motor.
Indicates power to the
igniter
Indicates power to
combustion blower
Status Light
Will be lit in either stove
or room temp mode
when pointer is not
within off position band
except after normal shut
down. Blinks to indicate
errors listed below.
Indicates power to
distribution blower.
Status light error messages:
3 Blinks:IndicatesanincompleteESPcircuit,orthattheESP
(ExhaustSensingProbe)Hasgoneoutofrangeaspecic
numberof times.Thismay indicate theneedfor cleaning
theexhaust.Performamanualreset*.Ifthecodepersists,
contactyourdealer.
4 Blinks: Can occur only in Room Temp Mode and
indicatesRoomSensing Probe failed ornotinstalled. If a
RoomSensingProbeistheninstalled,thestatuslightwill
automaticallyreset.
5 Blinks (In Igniter Auto. Mode Only):Indicatesthattheunit
hasfailedtolightwithinthe36minutestartcycle.Toreset-
TurnModeSelectorto"OFF",thenturntoeithermodeagain.
6 Blinks :Indicatesthatthecontrolhascalculatedpooror
incompletecombustionoccurringformorethan25minutes.
Asixblinkstatusmaybesetifthestoveisallowedtorunout
ofpellets.Toreset,turnmodeselectorto"OFF"thenback
ontothedesiredmode.Iftheunitwasnotoutofpellets,see
Troubleshootingsection,Page28,formoredetails.
* Manual reset-disconnectpowercordforafewseconds
andreconnect.IferrorstilloccurscallyourDealer.
Dealer Diagnostic Port
For dealer maintenance
only. Requires special
DDM monitor supplied
to Harman Dealers
exclusively.
Igniter switch
Set to appropriate Start-
Up mode.
20
P68 Pellet Stove
3-90-00688R24_06/13
Low Draft Voltage Adjustment
Theseunitsarepre-testedatthefactorywithexactly120VAC,
60Hz.Theyarecheckedandadjustedforreboxtightness,
gasketleakage,motoroperationandigniteroperation.The
P68isthenfactorysetatamid-pointadjustmentandinmost
caseswillnotneedanyadjustments.
NOTE: The factory low draft setting may not be correct
for the unit's permanent installation conditions.
ThecontrolboardontheP68isequippedwithalowdraft
adjustmentport.Locatedonthecontrolfacejusttotheright
oftheigniterlight.Thisvoltageadjustmentisprovidedtoallow
theunittobeadjustedforthehouseholdvoltagewherethe
unitisgoingtobeinpermanentoperation.NOTE: The line
voltage varies from area to area and often home to home.
Thelowdraftvoltageshouldbeadjustedtoachievethemost
efcient burn on low burn or "maintenance". This voltage
adjustmentallowstheinstallertochangethelowvoltageset
pointapproximately10volts.Thisadjustmentshouldbedone
bytheinstallerduringsetupbecauseadraftmeterreading
isrequired toinsurepropersetup.
Iftheunitisnotadjustedproperly,itdoesnotcauseasafety
concern.Iftheunitisadjustedtoohigh,onlyefencyislost.
Iftheunitisadjustedtoolow,thelowdraftpressureswitch
willnotallowthefeedmotorortheignitertooperate.
Combustion Motor
Speed Control
Low draft only set
point.
The small straight
screwdriver slot is
plastic; therefore, the
unit can be adjusted
while in operation.
Fig.22 Fig. 23
Draft Meter bolt hole
location
On a P68 the draft test
hole is under the left rear
corner of the rebox.
Low Draft Voltage Adjustment
Asimpledrafttestshouldbeperformedaftercompletingthe
uepipeinstallation.Torecordtheresultsforfuturereference:
1. Plugunitintoa120VAC,60HZoutlet.
2. Closethehopperlid,frontviewdoor,andtheashpan.
Neitherpelletsorarearerequiredforthistest.
3. Withthemodeselectorinthe"OFF"position,turnthefeed
adjusterto"TEST".
4. Recordthehighdraft_____inW.C.(Normalis-.50to-.60)
ThecontrolwillbeontheHighDraftforatotalof1minute.
5. Afteraminute,thecombustionmotorwillgodowntolow
draft and the distribution blower will go on high.Allow
approximately 15 seconds to pass for the combustion
motortoslowbeforecheckingthelowdraft.
6. Ifthelowdraftisbetween-.35and-.45,recordthereading
_____inW.C.Ifthereadingishigher, slowly turn the
setscrewcounter-clockwiseuntilthedraftlowers.Ifthe
readingislower,veryslowlyturnthesetscrewclockwise
untilthedraftincreases.
NOTE: In some cases, the draft may not go as low as
-.35 to -.45 even with the set screw completely counter-
clockwise. Ideally, you should just set it as low as
possible.
Ifthereisnochangeindraftreadingbetweenhighandlow
voltage,checkforobstructionsintheairintakeortheoutside
airconnection,ifinstalled.
/