Siemens Microscope & Magnifier A1 User manual

  • Hello! I am an AI chatbot trained to assist you with the Siemens Microscope & Magnifier A1 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
MICROMASTER
User Documentation
Applications Handbook Issue A1
ii MICROMASTER Applications Handbook
Further information is available on the Internet under:
http://www.siemens.de/micromaster
Approved Siemens Quality for Software and Training
is to DIN ISO 9001, Reg. No. 2160-01
The reproduction, transmission or use of this document, or its
contents is not permitted unless authorized in writing.
Offenders will be liable for damages. All rights including rights
created by patent grant or registration of a utility model or
design are reserved.
© Siemens AG 2000. All Rights Reserved.
MICROMASTER® is a registered trademark of Siemens.
Other functions not described in this document may be
available. However, this fact shall not constitute an obligation
to supply such functions with a new control, or when
servicing.
We have checked that the contents of this document
correspond to the hardware and software described. There
may be discrepancies nevertheless, and no guarantee can be
given that they are completely identical. The information
contained in this document is reviewed regularly and any
necessary changes will be included in the next edition. We
welcome suggestions for improvement.
Siemens handbooks are printed on chlorine-free paper that
has been produced from managed sustainable forests. No
solvents have been used in the printing or binding process.
Document subject to change without prior notice.
Printed in the United Kingdom
Siemens-Aktiengesellschaft.
MICROMASTER Applications Handbook iii
Valid for A1 Release
Inverter Type Control Version
MICROMASTER MM4
Issue: A1
MICROMASTER
Applications Handbook
User Documentation
Introduction
1
Siemens Drives
Product Range
2
Selecting a Drive
3
Getting Started
4
Simple Applications
5
Electromagnetic
Compatibility
6
Real Applications
7
Advanced
Applications
8
Options
9
Appendices
A
B
Index
iv MICROMASTER Applications Handbook
International English Contents
MICROMASTER Applications Handbook v
Table of Contents
1 Introduction ............................................................................................................... 1
1.1 What is a Variable Speed Drive? ................................................................................ 1
1.2 The Variable Frequency Inverter................................................................................. 3
2 Siemens Drives Product Range............................................................................... 7
3 Selecting a Drive ....................................................................................................... 9
3.1 Overall Considerations ................................................................................................ 9
3.2 Supply Side Requirements.......................................................................................... 9
3.3 Motor limitations .......................................................................................................... 12
3.4 Load Considerations ................................................................................................... 13
3.5 Acceleration and Braking requirements ...................................................................... 15
3.6 Environmental Considerations .................................................................................... 16
4 Getting Started with an Inverter............................................................................... 17
4.1 Mounting the Inverter .................................................................................................. 17
4.2 Cooling ........................................................................................................................ 17
4.3 Wiring up the Inverter .................................................................................................. 17
4.4 First Switch On ............................................................................................................ 20
5 Applications and Possibilities ................................................................................. 21
5.1 Using a Potentiometer with the Analog Input.............................................................. 21
5.2 Using all the Digital Inputs........................................................................................... 21
5.3 Selecting and Using the Fixed Frequencies ............................................................... 22
5.4 Using other digital input features................................................................................. 22
5.5 Using the control outputs ............................................................................................ 23
5.6 Current Limit and Protection Systems......................................................................... 24
5.7 Other Protection Features........................................................................................... 24
5.8 Some Additional Features........................................................................................... 25
Contents International English
vi MICROMASTER Applications Handbook
6 Electromagnetic Compatibility (EMC)..................................................................... 29
6.1 What is EMC? ............................................................................................................. 29
6.2 Minimising the problem of EMI.................................................................................... 29
6.3 EMC Rules and Regulations ....................................................................................... 33
7 Real Applications ...................................................................................................... 35
7.1 A Simple Fan Application ............................................................................................ 35
7.2 A Closed Loop Controller using a Fan ........................................................................ 36
7.3 Controlling Lift Door Operation.................................................................................... 39
7.4 A Conveyor Application using several MICROMASTERs .......................................... 41
7.5 A Material Handling Application .................................................................................. 43
7.6 An Exercise Machine Application................................................................................ 45
8 Advanced Applications Information........................................................................ 47
8.1 Using Closed Loop Control ......................................................................................... 47
8.2 Braking and Slowing down using Inverters ................................................................. 49
8.3 Using the Serial Interface............................................................................................ 51
8.4 Using PROFIBUS........................................................................................................ 52
8.5 Vector and FCC Control.............................................................................................. 53
9 Options for Siemens Standard Drives .................................................................... 57
9.1 Introduction.................................................................................................................. 57
9.2 Advanced Operating Panel AOP................................................................................. 57
9.3 Braking Modules and Braking Resistors .................................................................... 58
9.4 EMC Filters.................................................................................................................. 58
9.5 PROFIBUS Module ..................................................................................................... 58
9.6 Input and Output Chokes ............................................................................................ 58
A Environmental Protection Levels (IP rating) .......................................................... 59
B Some Useful Formulae ............................................................................................. 61
B.1 Torque and Power Relationships ................................................................................ 61
International English Contents
MICROMASTER Applications Handbook vii
List of Figures
Figure 1-1 Induction Motor. Simplified Cross Section ............................................. 1
Figure 1-2 Torque Speed Characteristics of an Induction
Motor ...................................................................................................... 2
Figure 1-3 Torque Reduction above Base Speed.................................................... 3
Figure 1-4 Inverter Block Diagram ........................................................................... 3
Figure 1-5 Pulse Width Modulation.......................................................................... 4
Figure 3-1 Sources of Supply Disturbance .............................................................. 10
Figure 3-2 Rectifier Input Voltages and Currents..................................................... 11
Figure 3-3 Typical Harmonic currents in 230 V single and
three-phase supplies, (750 W Inverter)................................................... 12
Figure 3-4 Operating Capabilities of Motor/Inverter
Combinations.......................................................................................... 13
Figure 3-5 Torque/Speed Characteristics ................................................................ 14
Figure 3-6 Variable Torque/Load Characteristics .................................................... 14
Figure 3-7 Matching the load to the Motor/Inverter
Capabilities............................................................................................. 15
Figure 4-1 Input Wiring. Single-Phase Supplies ..................................................... 18
Figure 4-2 Input Wiring. Three-Phase Supplies ...................................................... 18
Figure 4-3 1AC or 3AC, 230 V Input. (Motor usually Delta
Connected)............................................................................................. 18
Figure 4-4 3AC, 400 – 575 V Input. (Motor usually Star
Connected)............................................................................................. 18
Figure 4-5 Typical Installation .................................................................................. 19
Figure 5-1 Using a Potentiometer with the Analog Input.......................................... 21
Figure 5-2 Using all the Digital Inputs ...................................................................... 22
Figure 5-3 Composite Control Cycle........................................................................ 23
Figure 5-4 Smoothing applied to UP and DOWN ramps.......................................... 25
Figure 5-5 Possible control cycle using brake control relay
and times................................................................................................ 26
Figure 5-6 Slip Compensation ................................................................................. 27
Figure 5-7 Voltage Boost ......................................................................................... 28
Figure 6-1 EMC. Emissions and Immunity.............................................................. 29
Figure 6-2 Star Point Grounding .............................................................................. 31
Figure 6-3 Screening of Control Cables................................................................... 31
Figure 6-4 Separation of Control and Power Connections....................................... 31
Figure 6-5 Suppression of Contactor Coils .............................................................. 32
Figure 6-6 Use of Screened or Armoured Cables.................................................... 32
Contents International English
viii MICROMASTER Applications Handbook
Figure 7-1 Fan Application....................................................................................... 35
Figure 7-2 Extractor System using Closed Loop Flow
Control.................................................................................................... 37
Figure 7-3 Lift Door Operation ................................................................................. 39
Figure 7-4 Conveyor Application............................................................................. 41
Figure 7-5 Material Handling Application ................................................................. 43
Figure 7-6 Exercise Machine ................................................................................... 45
Figure 8-1 A Typical Closed Loop Controller ........................................................... 48
Figure 8-2 Graph showing the Motor acting as a Generator.................................... 49
Figure 8-3 Absorbing Regenerated Current............................................................. 50
Figure 8-4 Braking Methods..................................................................................... 51
Figure 8-5 Vector Diagram. Load Current against Flux
Current.................................................................................................... 53
Figure 8-6 Comparison. DC Motor/AC Motor.......................................................... 54
Figure 8-7 Position Fedback via a Motor Shaft Encoder.......................................... 54
Figure B-1 Practical Assemblies. Gearbox.............................................................. 61
Figure B-2 Practical Assemblies. Conveyor ............................................................ 62
List of Tables
Table 7-1 Fan Application with Manual Control ...................................................... 36
Table 7-2 Fan Application with Closed Loop Control.............................................. 38
Table 7-3 Key Parameters. Lift Door Operation..................................................... 40
Table 7-4 Key Parameters. Conveyor Application ................................................. 42
Table 7-5 Key Parameters. Material Handling Operation ...................................... 44
Table 7-6 Key Parameters. An Exercise Machine
Operation................................................................................................ 46
Table A-1 Protection levels (IP Rating) ................................................................... 59
International English Introduction
MICROMASTER Applications Handbook 1
1 Introduction
This manual is intended to help users of variable speed drives successfully install
and utilize Siemens Standard Drives.
It includes an introduction to drives, which may be informative to first time users.
Detailed technical information and complete parameter descriptions are available
in the Reference Manual and the Parameter List.
INTERNET Address:
http://www.siemens.de/micromaster
These sites will allow access to handbooks, application and training information, as
well as Frequently Asked Questions. (FAQs).
1.1 What is a Variable Speed Drive?
A Variable Speed Drive (VSD) consists of a Motor and some form of controller.
Early electric VSDs consisted of AC and DC motors combinations which were used
as rotating controllers. The first electronic controllers used Thyristor (SCR)
Rectifiers which controlled the voltage, and therefore the speed of DC motors.
These DC VSDs are still widely used and offer very sophisticated control capability.
However, the DC motor is large, expensive and requires periodic brush
maintenance. The AC induction motor is simple, low cost, reliable and widely used
throughout the world.
In order to control the speed of an AC induction motor a more complex controller,
usually called an inverter is required.
In order to understand how an inverter works, it is necessary to understand how an
induction motor works.
An induction motor works like a transformer. When the stator (the fixed, outer
winding) is connected to a three-phase power source, a magnetic field is set up
which rotates at the frequency of the supply.
Figure 1-1 shows a simplified cross-section of an induction motor.
1
2
3
1
2
3
Stator Windings
Air Gap
Rotor
Shaft
Figure 1-1 Induction Motor. Simplified Cross Section
Introduction International English
2 MICROMASTER Applications Handbook
This field crosses the air gap between the stator and rotor and causes currents to
flow in the rotor windings. This produces a force on the rotor as the current
interacts with the changing magnetic field, and the rotor turns.
If the windings are arranged in several pairs (or poles), the frequency of the
rotating field will be less than the applied frequency (e.g. two pole = 50/60 Hz =
3000/3600 rpm, but four pole = 50/60 Hz = 1500/1800 rpm). However, if the rotor
runs at the same speed as the rotating field, there will be no changing
magnetic
field, and therefore no torque. Therefore the rotor always runs a little slower than
the rotating field in order to generate torque. This difference in speed is known as
slip
.
You can see that the speed of the motor depends on the applied frequency, as well
as the winding arrangement, and a little on the load. Therefore in order to control
the motor speed it is necessary to control the frequency of the supply.
If the frequency is reduced, the voltage must be reduced or the magnetic flux will
be too high and the motor will saturate so the voltage must be controlled as well. If
the frequency is increased above normal, more voltage would normally be needed
to maintain maximum flux. Since this is not usually possible, less torque is
available at high speed.
Speed
Normal Operating
Point
Slip
Pull out (Maximum)
Torque
Torque
Variable frequency operation
Figure 1-2 Torque Speed Characteristics of an Induction Motor
International English Introduction
MICROMASTER Applications Handbook 3
Torque
Flux, Voltage
Speed ( X 50/60)
Torque
Capability
0 0.5 1.0 1.2 1.5
Figure 1-3 Torque Reduction above Base Speed
Therefore in order to control the speed of a standard AC motor, the applied
frequency and voltage must be controlled.
Although it is difficult to control voltage and frequencies at these high powers, the
use of a standard induction motor allows a cost-effective speed control system to
be built.
1.2 The Variable Frequency Inverter
An electronic converter that converts Direct Current (DC) to Alternating Current
(AC) is known as an inverter. Electronic speed controllers for AC motors usually
convert the AC supply to DC using a rectifier, and then convert it back to a variable
frequency, variable voltage AC supply using an inverter bridge. The connection
between the rectifier and inverter is called the DC link. The block diagram of a
speed controller (often called an inverter) is shown in Figure 1-4.
Motor
Supply
Rectifier DC Link Inverter
+
-
Figure 1-4 Inverter Block Diagram
Introduction International English
4 MICROMASTER Applications Handbook
The supply, which can be single phase (usually at low power) or three-phase is fed
to a full wave rectifier which supplies the DC link capacitors. The capacitors
reduce the voltage ripple (especially on single-phase supplies) and supply energy
for short breaks in the input supply. The voltage on the capacitors is uncontrolled
and depends on the peak AC supply voltage.
The DC voltage is converted back to AC using Pulse Width Modulation (PWM).
The desired waveform is built up by switching the output transistors (Insulated
Gate Bipolar Transistors (IGBTs) on and off at a fixed frequency (the switching
frequency). By varying the on and off time of the IGBTs the desired current can be
generated, but the output voltage is still a series of square wave pulses. Pulse
Width Modulation is shown in Figure 1-5.
0 V
Time
Voltage
Current
Figure 1-5 Pulse Width Modulation
There are many complex aspects of inverters which need to be considered during
the design:
· The control system to calculate the PWM requirements is very complex and
specially designed integrated circuits (ASICs) are needed.
· The control electronics are often connected to the DC link, which is connected
to the supply, so the customer connections, display etc. must be safely isolated
from this.
· The output current must be carefully monitored to protect the inverter and the
motor during overload and short circuit.
· At first switch on the DC link capacitors are discharged, and the inrush current
must be limited, usually using a resistor which is bypassed by a relay after a few
seconds.
· All connections to the inverter, especially the supply and control connections,
may carry a lot of interference and must be fitted with suitable protection
components.
· An internal power supply with several different output voltages is needed to
supply the control electronics.
· The inverter, especially the IGBTs and rectifier diodes, produce heat which
must be dissipated using a fan and heatsink.
International English Introduction
MICROMASTER Applications Handbook 5
· The PWM output voltage contains many high frequency harmonics (because of
the fast switching) and can be a major source of EMI.
· The input rectifier draws current only at the peak of the supply waveform, so the
input currents have a poor form factor ( i.e. the RMS value can be quite high -
this does not mean the inverter is inefficient!).
A practical inverter needs to be designed for ease of use and installation. Large
inverters are often specially designed or engineered for each application; smaller
inverters are designed for general purpose use and are of standard design.
Siemens Standard Drives division manufacture standard inverters for this purpose.
Introduction International English
6 MICROMASTER Applications Handbook
International English Product Range
MICROMASTER Applications Handbook 7
2 Siemens Drives Product Range
The current product range consists of several different product types:
The MICROMASTER Vector (MM440). A VSD high performance inverter for
general purpose applications available in various voltage ranges.
The MICROMASTER (MM420). A similar range with fewer features for simple
applications.
The MICROMASTER Eco. A VSD especially designed for Heating, Ventilating and
Air Conditioning applications.
The COMBIMASTER. An induction motor with an inverter mounted in place of the
terminal box.
Larger and more sophisticated drives for engineered applications can be supplied
by other Siemens drives divisions.
The following information refers to the operation of the MICROMASTER products
in particular, but is applicable to all VSDs.
Product Range International English
8 MICROMASTER Applications Handbook
International English Selecting a Drive
MICROMASTER Applications Handbook 9
3 Selecting a Drive
Often drive selection is straight forward, as a motor is already installed and the
speed range requirement is not excessive. However, when a drive system is
selected from first principles, careful consideration may avoid problems in
installation and operation, and may also save significant cost.
3.1 Overall Considerations
Check the Current rating of the inverter and the motor. Power rating is only a
rough guide.
Check that you have selected the correct operating voltage. 230 V three-phase
input MICROMASTERs will operate with single or three-phase inputs. 400 V
MICROMASTERs are for three-phase application only. Single-phase input units
can be more cost effective in some cases, but note that 230 V units will be
damaged if operated at 400 V. See section 3.2.1.
Check the speed range you require. Operation above normal supply frequency (50
or 60 Hz) is usually only possible at reduced power. Operation at low frequency
and high torque can cause the motor to overheat due to lack of cooling.
Synchronous motors require de-rating, typically by 2-3 times. This is because the
power factor, and hence the current, can be very high at low frequency.
Check overload performance. The inverter will limit current to 150 or 200% of full
current very quickly. A standard, fixed speed motor will tolerate these overloads.
Do you need to stop quickly? If so, consider using a braking resistor to absorb the
energy. A separate braking unit may be required for some VSDs. See section 0,
Do you need to operate with cables longer than 50m, or screened or armored
cables longer than 25m? If so, it may be necessary to de-rate, or fit a choke to
compensate for the cable capacitance.
3.2 Supply Side Requirements
In order to achieve reliable operation, the main power supply to the inverter system
must be suited to the inverter and the anticipated power supplied. The following
points should be considered:
3.2.1 Supply Tolerance
Inverters are usually designed to operate on a wide range of supply voltages. For
example:
Low Voltage units 200 - 240 V ±10% i.e. 180 - 264 V
High Voltage units 380 - 480 V ±10% i.e. 342 - 528 V
Very High Voltage units 500 - 600 V ±10% i.e. 450 - 660 V
Inverters will operate over a wide supply frequency range, typically 47 - 63 Hz
However, many supplies vary outside these voltage levels. For example:
Selecting a Drive International English
10 MICROMASTER Applications Handbook
Supplies at the end of long power lines in remote areas can rise excessively in the
evening and weekends when large loads are no longer present.
Industries with locally controlled and generated supplies can have poor regulation
and control.
Power systems in certain parts of the world may not meet expected tolerances.
In all installations, check that the supply will remain within the tolerances stated
above. Operation outside of the stated supply levels will probably cause damage.
3.2.2 Supply Disturbance
Many supplies are well controlled and remain in tolerance, but are affected by local
disturbances. These can cause faulty operation and damage to inverters. In
particular, check for:
· Power Factor Correction equipment. Unsuppressed switching of capacitor
banks can produce very large voltage transients and is a common cause of
inverter damage.
· High power welding equipment, especially resistance and RF welders.
· Other drives (in particular large, old DC drives), semiconductor heater
controllers etc.
Note.
Inverters are designed to absorb high levels of supply disturbance. Voltage spikes
up to 4 kV for instance. However, the above equipment can cause power supply
disturbances in excess of this. It will be necessary to suppress this interference -
preferably at source - or at least by the installation of an input choke in the inverter
supply. EMC filters do not suppress disturbances with this level of energy; over
voltage protection products such as metal oxide varistors should be considered.
Damage can also be caused by local supply faults and the effects of electrical
storms. In areas where these are expected, similar precautions are recommended.
Figure 3-1 Sources of Supply Disturbance
MICROMASTER
Motor
Power Factor
Correction
Equipment
Welders
RF Heaters etc.
Large Drives and
Power Electronic
Systems
Lightning, Power
System Faults
Add input inductor and
Over Voltage Protection
Equipment here.
International English Selecting a Drive
MICROMASTER Applications Handbook 11
3.2.3 Ungrounded Supplies
Certain industrial installations operate with supplies that are isolated from the
protective earth (IT supply). This permits equipment to continue to run following an
earth fault. However, MICROMASTERs are designed to operate on grounded
supplies and are fitted with interference suppression capacitors between the supply
and ground. Hence operation on ungrounded supplies may be restricted. Some
inverters are designed to allow the removal of these capacitors and enable limited
operation with ungrounded supplies. Please consult Siemens for clarification.
3.2.4 Low Frequency Harmonics
The inverter converts the AC supply to DC using an uncontrolled diode rectifier
bridge. The DC link voltage is close to the peak AC supply voltage, so the diodes
only conduct for a short time at the peak of the AC waveform.
The current waveform therefore has a relatively high RMS value as high current
flows from the supply for a short time.
Input Voltage Input Current DC Link Voltage
Single Phase
Three Phase
Figure 3-2 Rectifier Input Voltages and Currents
This means that the current waveform is consists of a series of low frequency
harmonics, and this may in turn cause voltage harmonic distortion, depending on
the supply impedance.
Sometimes these harmonics need to be assessed in order to ensure that certain
levels are not exceeded. Excessive harmonic levels can cause high losses in
transformers, and may interfere with other equipment. In any case, the rating and
selection of cabling and protection equipment must take these high RMS levels into
account. Some measured harmonic levels are shown In Figure 3-3.
Selecting a Drive International English
12 MICROMASTER Applications Handbook
Figure 3-3 Typical Harmonic currents in 230 V single and three-phase supplies,
(750 W Inverter).
In order to calculate the harmonics in a particular supply system it is essential that
the supply impedance is known. This is usually stated in terms of fault current
levels, transformer size and installed impedance such as line inductors etc.
Computer programs are available to calculate the current and voltage harmonic
levels, dependent on the load, type and number of inverters in the system. In
general, industrial supplies do not require this level of assessment.
Where supplies have very low impedance (such as below 1%) an input inductor is
recommended in any case to limit peak currents in the drive.
3.3 Motor limitations
For more information concerning calculation of Power requirements, Torque, and
Moment of Inertia, see Appendix B.
The motor speed is determined mainly by the applied frequency. The motor slows
down a little as the load increases and the slip increases. If the load is too great
the motor will exceed the maximum torque and stall or ‘pull out’. Most motors and
inverters will operate at 150% load for a short time, (60 seconds for instance).
The motor is usually cooled by a built in fan that runs at motor speed. This is
designed to cool the motor at full load and base speed. If a motor runs at a lower
frequency and full torque - that is high current - cooling may be inadequate. Motor
manufacturers will give the necessary de-rating information, but a typical derating
curve would limit output torque to 75% at zero frequency rising to full capability at
50% of base speed. See Figure 3-4. Ensure that these limitations are not
exceeded for long term operation.
Consider using the I
2
t function to help protect the motor ( see section 5.7.1) or
consider using a motor with built in protection such as a PTC.
0
1
2
3
4
5
6
7
Fundamental
3rd
5th
7th
9th
11
th
13
t
h
15
t
h
1ph 750W
3ph 750W
/