Mitsubishi Electric FR-A7CN User manual

Type
User manual
1
INVERTER
Heatsink Protrusion Attachment
<FR-A7CN01 to 14>
Thank you for selecting the Mitsubishi Electric inverter option unit.
This instruction manual gives handling information and precautions for use of this equipment. Incorrect handing might cause an
unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum.
Please forward this instruction manual to the end user.
This attachment allows approximately 70% of the heat generated by the inverter (high power factor converter) to be radiated outside the
enclosure by protruding the inverter (high power factor converter) heatsink section out from the rear side of the enclosure.
1. Preparation
1) Confirm the attachment model.
2) Confirm that the following parts are enclosed with the indicated quantity.
*1) For the FR-A7CN05 to 14 lower installation frame, use an inverter (high power factor converter) frame by changing its' installation position.
*2) Use inverter (high power factor converter) screws.
3) Applicable model
Safety Precautions
While power is ON or for some time after power-OFF, do not touch the inverter (high power factor converter) and attachment as they will be
extremely hot. Doing so can cause burns.
The product must be transported in correct method that corresponds to the weight. Failure to do so may lead to injuries. Take special care
with the edge sections.
Do not allow conductive foreign matter such as screws, metal chips, or flammable foreign matter such as oil enter the inverter (high power
factor converter).
No. Name
Attachment Model
FR-A7CN01 to 03 FR-A7CN04 FR-A7CN05 to 07 FR-A7CN08, 09 FR-A7CN10 to 14
1)
Upper installation frame 1 1 1 1 1
2)
Upper cover 1 1 1 1 1
3)
Lower installation frame 1 1 *1) *1) *1)
4)
Frame installation screw 4 (M5) 4 (M8) *2) *2) *2)
5)
Cover installation screw 2 (M4) 2 (M4) 6 (M4) 6 (M4) 6 (M4)
6)
Right installation frame  111
7)
Left installation frame  111
8)
Sticker  2 
Applicable
model
Applicable Attachment
FR-A7CN01 FR-A7CN02 FR-A7CN03 FR-A7CN04 FR-A7CN05 FR-A7CN06 FR-A7CN07 FR-A7CN08 FR-A7CN09 FR-A7CN10 FR-A7CN11 FR-A7CN12 FR-A7CN13 FR-A7CN14
FR-F720(P)
2.2K
3.7K
5.5K
7.5K
11K
15K 18.5K
22K
30K
37K  45K
55K
75K
90K
110K

FR-F740(P)
0.75K
1.5K
2.2K
3.7K
5.5K
7.5K
11K
15K
18.5K
22K
30K
 37K 45K
55K
75K
90K 110K 132K
160K

FR-A720
1.5K
2.2K
3.7K
5.5K
7.5K
11K 15K
18.5K
22K
30K  37K
45K

 75K
90K
55K 
FR-A740
0.4K
0.75K
1.5K
2.2K
3.7K
5.5K
7.5K
11K
15K
18.5K
22K
 30K 37K
45K
55K
75K 90K 110K
132K

FR-HC2
 7.5K H7.5K
H15K
15K 30K
H30K
75K
H110K
55K H75K H55K
2
2. Installation
1) Cut the enclosure with the following dimensions according to the inverter (high power factor converter) capacity.
FR-A7CN01
FR-A7CN02 FR-A7CN03 FR-A7CN04
FR-A7CN05 FR-A7CN06 FR-A7CN07
Applicable model Applicable model Applicable model
FR-F720(P)-37K FR-F740(P)-37K FR-F720(P)-45K
,
55K
FR-A720-30K FR-A740-30K FR-F740(P)-45K
,
55K
,
75K
FR-HC2-30K FR-A720-37K
,
45K
FR-HC2-H30K FR-A740-37K
,
45K
,
55K
6-M5 screw
112
100
90
280
7.5
265
365
136
145
(Unit:mm)
Applicable model
FR-F720(P)-2.2K to 5.5K
FR-F740(P)-0.75K to 5.5K
FR-A720-1.5K to 3.7K
FR-A740-0.4K to 3.7K
175
102
90
280
7.5
265
367
195
212
6-M5 screw
(Unit:mm)
Applicable model
FR-F720(P)-7.5K, 11K
FR-F740(P)-7.5K, 11K
FR-A720-5.5K, 7.5K
FR-A740-5.5K, 7.5K
FR-HC2-7.5K
175
102
90
320
7.5
305
407
195
212
6-M5 screw
(Unit:mm)
Applicable model
FR-F720(P)-15K
FR-F740(P)-15K, 18.5K
FR-A720-11K
FR-A740-11K, 15K
FR-HC2-H7.5K, H15K
12.5
230
40
40
102
335
517
244
200
260
90
440
(Unit:mm)
6-M8
screw
Applicable model
FR-F720(P)-18.5K to 30K
FR-F740(P)-22K, 30K
FR-A720-15K to 22K
FR-A740-18.5K, 22K
FR-HC2-15K
4-M8 screw
279
516
270
70
298
600
12
330
586
(Unit:mm)
6-M8 screw
265
516
270
95
290
540 85
12
330
611
(Unit:mm)
380
440
4-M10 screw
510
105
590
15
380
410
615
(Unit:mm)
3
2) Refer to "4. Heatsink protrusion attachment and inverter (high power factor converter) assembly" to assemble. After
assembly, install the inverter (high power factor converter) in the enclosure.
FR-A7CN08, 09
FR-A7CN10 FR-A7CN11
Applicable model Applicable model Applicable model
FR-F740(P)-90K
,
110K FR-F720(P)-75K, 90K, 110K FR-A720-55K
FR-A740-75K
,
90K FR-F740(P)-132K
,
160K
FR-HC2-75K FR-A720-75K
,
90K
FR-HC2-H110K FR-A740-110K
,
132K
FR-A7CN12 FR-A7CN13 FR-A7CN14
Applicable model Applicable model Applicable model
FR-HC2-55K FR-HC2-H75K FR-HC2-H55K
NOTE
ï‚Ÿ Having a cooling fan, the cooling section which comes out of the enclosure cannot be used in the environment of
water drops, oil, mist, dust, etc.
ï‚Ÿ Be careful not to drop screws, dust etc. into the inverter (high power factor converter) and cooling fan section.
ï‚Ÿ There is 1mm of clearance between the FR-A7CN and inverter (high power factor converter). (The inverter (high
power factor converter) is not in an enclosed condition)
440
477
4-M10 screw
582
108
660
13
400
470
690
(Unit:mm)
440
477
4-M10 screw
702
108
780
13
400
470
810
(Unit:mm)
440
477
4-M10 screw
662
108
740
13
410
470
770
(Unit:mm)
279
298
660
332
70
576
12
270
4-M8 screw
(Unit:mm)
300
12
710
338
300
626
377
70
4-M8 screw
(Unit:mm)
4
3. Outline dimension drawings
(------ : Panel cut dimensions)
FR-A7CN01 FR-A7CN02
FR-A7CN03 FR-A7CN04
FR-A7CN05 FR-A7CN06
2.3
280
389.5
8
90
(11.5)
136
150
18
111.5
(260)
97
43
23.3
(140)
(5.4)
Attachment
6- 6 screw
Attachment
Panel
Panel
(Unit: mm)
195
245
(5.4)
84
86
2.3
12.3
(16.5)
116.5(260)
32
90
280
72
22
408.5
156
(170)
6- 6.5 screw
Attachment
Panel
(Unit: mm)
Panel
Attachment
195
245
(5.4)
101
89
2.3
20
(16.5)
116.5(300)
32
90
320
72
22
448.5
156
(190)
Panel
Attachment
6- 6.5 screw
(Unit: mm)
Panel
Attachment
230
280
45.3
(11.5)
440
554
122
(400)
32
12.5
90
172
82
88.5
2.3
101.5
(9.1)
(190)
Attachment
6- 10 screw
(Unit: mm)
Panel
Attachment
Panel
(344)
338
298
600
645
(480)
35
270
10
10
123.5
71.5
130
105
3.2
(195)
Panel
(35)
Attachment
Panel
2- 10 screw
(Unit: mm)
83.5
3.2
130
(480)
35
123.5
71.5
338
290
10
270
10
540
645
85
(10)
(195)
4- 10 screw
(Unit: mm)
Attachment
Panel
Panel
5
FR-A7CN07 FR-A7CN08, 09
FR-A7CN10 FR-A7CN11
FR-A7CN12 FR-A7CN13
55
3.2
145
(465)
40
96
154
(460)
410
451
12
380
10
590
650
(50)
(250)
Attachment
(Unit: mm)
Panel
2- 12 screw
Panel
400
12
10
660
725
(535)
40
116.5
183.5
(300)
150
(519)
510
470
45
3.2
2- 12 screw
Attachment
Panel
(Unit: mm)
Panel
(55)
400
12
10
40
183.5
150
(519)
510
470
45
3.2
780
845
(655)
176.5
(360)
2- 12 screw
Attachment
Panel
(Unit: mm)
Panel
(55)
(250)
153
3.2
(615)
805
740
410
12
10
97
40
(519)
510
470
(55)
150
45
2- 12 screw
Attachment
Panel
(Unit: mm)
Panel
383
338
10
10
300
705
(389)
660
Attachment
Panel
Panel
3.2
105
130
(535)
40
171.5
(250)
78.5
2- 10 screw
(Unit: mm)
(35)
298
338
(344)
66010
705
130
40
105
3.2
78.5171.5
270
10
(535)
(250)
Attachment
Panel
2- 10 screw
(Unit: mm)
Panel
(35)
6
4. Heatsink protrusion attachment and inverter (high power factor
converter) assembly
FR-A7CN14
FR-A7CN01 FR-A7CN02
FR-A7CN03 FR-A7CN04
383
(389)
338
(35)
10
10
300
755
40
(585)
130
105
3.2
78.5171.5
(250)
710
Attachment
Panel
2- 10 screw
(Unit: mm)
Panel
1) Upper installation frame
4) Frame installation screw M5
2) Upper cover
Inverter
5) Cover installation screw M4
*
Install after making sure
that the lug is firmly fitted
into the groove.
3)
Lower
installation frame
Cover
installation
screw M4
5)
2) Upper cover
3)
Lower
installation frame
1) Upper installation frame
4)
Frame installation
screw M5
Inverter
(high power
factor converter)
5)
Cover
installation
screw M4
2) Upper cover
3)
Lower
installation frame
1) Upper installation frame
Frame
installation
screw M5
Inverter
(high power
factor converter)
4)
5)
Cover
installation
screw M4
2) Upper cover
3)
Lower
installation frame
1) Upper installation frame
Frame installation
screw M8
Inverter
(high power
factor converter)
4)
7
FR-A7CN05 FR-A7CN06
FR-A7CN07 FR-A7CN08, 09
FR-A7CN10, 11 FR-A7CN12, 13, 14
REMARKS
Replacement procedure of the cooling fan
When replacing the cooling fan, "remove the upper cover 2)" and replace the cooling fan from the opening. (Refer to the
Instruction Manual of the inverter (high power factor converter) for details.)
Remove the standard
installation foot/upper
section.
*1
2) Upper cover
5)
Cover
installation
screw M4
7)
Left
installation
frame
6)
Right
installation
frame
Inverter
(high power
factor converter)
1)
Upper installation
frame
Frame installation screw
4)
3)
Lower installation frame *2
Remove the standard
installation foot/upper
section.
*1
2) Upper cover
5)
Cover
installation
screw M4
7)
Left
installation
frame
6)
Right
installation
frame
Inverter
1)
Upper installation
frame
Frame installation screw
4)
3)
Lower installation frame *2
Remove the standard
installation foot/upper
section.
*1
2) Upper cover
5)
Cover
installation
screw M4
7)
Left
installation
frame
6)
Right
installation
frame
Inverter
1)
Upper installation
frame
Frame installation screw
4)
3)
Lower installation frame *2
8) Sticker *4
8) Sticker *4
2) Upper cover
5)
Cover
installation
screw M4
7)
Left
installation
frame
Remove the standard
installation foot/upper
section.
*1
6)
Right
installation
frame
Inverter
(high power
factor converter)
1)
Upper installation
frame
Frame installation screw
4)
3)
Lower installation frame *2
2) Upper cover
5)
Cover
installation
screw M4
7)
Left
installation
frame
Remove the standard
installation foot/upper
section.
*1
6)
Right
installation
frame
Inverter
1)
Upper installation
frame
Frame installation screw
4)
3)
Lower installation frame *2
Remove the standard
installation foot/upper
section.
*1
2) Upper cover
5)
Cover
installation
screw M4
7)
Left
installation
frame
6)
Right
installation
frame
High power
factor converter
1)
Upper installation
frame
Frame installation screw
4)
3)
Lower installation frame *2
IB(NA)-0600221ENG-C (1211)MEE Specifications subject to change without notice.
*1 When carrying the inverter (high power factor converter), do not hold it by the upper frame section of "1) upper installation frame". Doing so
may change the frame shape.
*2 Change the position of the "standard installation foot/lower section" (same as "3) lower installation frame") and screw up both "6) 7) left and
right installation frames".
*3 For the FR-A7CN07 to 11, fit the "2) upper cover" to the "1) upper installation frame" first, and then install the "1) upper installation frame" to
the inverter (high power factor converter).
When installing an "2) upper cover" to the "1) upper installation frame", a gap may sometimes be left between the lower part of the "2) upper
cover" and the "1) upper installation frame". Install the upper cover after making sure that there is no gap.
*4 Place a "8) sticker" before installing the heatsink protrusion attachment. Slits are on the left and right sides of the inverter. Cover the slits on
both sides with stickers. (Sticker placement is not necessary for the high power factor converter.)
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
A gap may
be left.
Push the cover so that
there is no gap left.
Inverter
(high power factor converter)
2) Upper cover
1)
Upper installation
frame
8) Sticker
*Place a sticker
in this area
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Mitsubishi Electric FR-A7CN User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI