MICRO-EPSILON P115 Assembly Instructions

Type
Assembly Instructions
Draw-Wire Displacement Sensors
Series WDS
Model P115
Assembly Instructions
wireSENSOR
WDS- ... - P115 - U/I/P, dimensions in mm (inches), not to scale
measuring range 3,000 ... 5,000 mm
Precautionary Measures
- Do not let the measuring wire rewind without control (snap back).
> Danger of injury from whiplash effect of the wire with assembly bolts/clips,
destruction of wire and/or of sensor
- Do not pull the measuring wire over range.
> Damage to or destruction of the sensor is possible.
- Do not damage the measuring wire.
- Do not oil or grease the measuring wire.
- Do not bend the measuring wire.
- Do not pull the measuring wire at an angle.
- Do not allow to loop the measuring wire around objects.
- Do not fix the measuring wire to the target when wound up.
- Do not loop the messuring wire around parts of the body.
Sensor Assembly
Mount the sensor through mounting grooves for nut M4 DIN 934 or bolt M4
DIN 931.
The sensor does not have to be oriented in a special way.
Choose the installation position so that damage and soiling of the measuring
wire is avoided.
Proper Environment
- Protection class of sensor: IP 65
1
- Operating temperature: -20 to +80 °C (-4 to +176 °F)
- Storage temperature: -40 to +80 °C (-40 to +176 °F)
- Humidity: 5 - 95 % (non-condensing)
- Ambient pressure: atmospheric pressure
- Vibration: according to IEC 68-2-6
- Mechanical shock: according to IEC 68-2-27
1)
Models with male plug connection only with gasketed female plug
WDS- ... - P115 - U/I/P, dimensions in mm (inches), not to scale
measuring range 7,000 ... 15,000 mm
WDS- ... - P115 - HTL/TTL, dimensions in mm (inches), not to scale
WDS- ... - P115 - SSI, dimensions in mm (inches), not to scale
WDS- ... - P115 - CO/PB, dimensions in mm (inches), not to scale
Model A B
WDS - P115 - U/I/P WDS-3000-P115 186 (7.32) -
WDS-4000-P115 180 (7.09) -
WDS-5000-P115 180 (7.09) -
WDS - P115 - U/I/P WDS-7500-P115 37 (1.46) 153 (6.02)
WDS-10000-P115 44,5 (1.75) 196 (7.72)
WDS-15000-P115 60,5 (2.38) 228 (8.89)
WDS - P115- HTL/TTL
WDS - P115 - SSI
WDS - P115 - CO/PB
WDS-5000-P115 28.5 (1.12) 91 (3.58)
WDS-7500-P115 37 (1.46) 112 (4.40)
WDS-10000-P115 44.5 (1.75) 155 (6.10)
WDS-15000-P115 60.5 (2.38) 187 (7.36)
Dimensions in mm (inches)
145 (5.71)
60 (2.36)
60 (2.36)
ø58
(2.28 dia.)
50
(1.97)
A
80 (3.15)
ø30 (1.18 dia.)
60 (2.36) B53
(2.08)
115 (4.53)
4x M6
2x Slot nut
2x Fixation screw M4
ø20.2 (.79 dia.)
36
(1.42)
145 (5.71)
60 (2.36)
60 (2.36)
ø58
(2.28 dia.)
50
(1.97)
A
80 (3.15)
ø30 (1.18 dia.)
60 (2.36) B69
(2.72)
115 (4.53)
4x M6
2x Slot nut
2x Fixation screw M4
ø20.2 (.79 dia.)
36
(1.42)
145 (5.71)
60
(2.36)
60 (2.36)
ø58
(2.28 dia.)
50
(1.97)
A
80 (3.15)
ø30 (1.18 dia.)
60 (2.36) B101
(3.97)
115 (4.53)
4x M6
2x Slot nut
2x Fixation screw M4
ø20.2 (.79 dia.)
36
(1.42)
127.5 (5.02)
A
60
(2.36)
60 (2.36)
ø58
(2.28 dia.)
50
(1.97)
5
(.20)
17.6
(.69)
80 (3.15)
Cover bolt for Gain and ZERO-pot.
Cable bending
WDS - P115:
R > 20
(.79) one time
R > 75
(2.95) alternating
40
(1.57) respectively
100
(3.94) for CAN-bus
60
(2.36)
115 (4.53)
50 (1.97)
123 (4.84)
2x Fixation screw M4
2x Slot nut
4x M6
118 (4.65)13
(.51)
P115-SR-U/I
P115-CA-P
36
(1.42)
170.4 (6.71)
60 (2.36)
60 (2.36)
50
(1.97)
A
5
(.20)
80 (3.15)
60 (2.36) B
4x M6
2x Slot nut
2x Fixation screw M4
115 (4.53)
P115-SR-U/I
P115-CA-P
36
(1.42)
Cover bolt for Gain and ZERO-pot.
*X9771034.03-A04*
X9771034.03-A041115GBR
Wire Guide and Fastening
If the measuring wire has to be extracted from the sensor to guide the wire
resp. to fix it to the target
- the sensor may not be held by another person
- the measuring wire may not be further extracted but only to the specified
measuring range
- the surroundings of the sensor have to be protected against snapping of
the measuring wire
Fix the measuring wire to the target using a wiring clip.
Fed the measuring wire perpendicularly from the sensor housing.
A misalignment is only permissible up to 3 degrees.
If you drag of the measuring wire on the inlet hole or other objects, this leads
for damaging and/or snapping of the measuring wire.
If you cannot fed the measuring wire vertically out of the housing, it is essen-
tial to use a guide pulley (accessory TR1-WDS).
Keep the measuring wire in an area where it cannot be snagged or otherwise
be violated.
Wire outlet 0 °
±3 ° tolerancy
max. 3 °
Dimensional wire fastening and misalignment
Power Supply and Display/Output Device
Electrical connection Output
- CR - integrated cable - SR - connector - P - potentiometer
color DIN 47 100 Pin
white 1 input +
brown 2 ground
green 3 signal
screen screen housing
Connection pin assignment WDS- ... - Pxx - CR - P
Electrical connection Output
-- SR-
1
device plug
DIN 45 326
- U
voltage
- I
current
Pin - Nr.
1 supply +
2 ground
3 signal ---
4
ground
(signal)
---
Connection pin assignment WDS- ... - Pxx - SR - U/I
8
1
2
3
4
5
6
7
View of solder pin
side 8-pole female
cable connector
1)
Pin 5 - 8 are not connected.
R1k
0 %
R1k
100 %
Measuring range
1
2
3
R1K
100 %
0 %
Input +
Ground
Signal
Model with potentiometer
output
A pre-assembled connecting
cable PC3/8 is available as an
accessory.
Note for the user-side assembly
of a cable:
1
2
0 - 10 V
U
zero gain
3
4
Supply
Ground
Signal
Ground
Model with voltage output
1
2
4 - 20 mA
I
zero gain
Supply
Ground
Model with current output
- Use a screened cable.
- Earth the screen on electronics side.
- Recommended conductor cross-section 0.14 mm
2
(up to 9 m/30 ft cable length)
- Maximum cable diameter 8 mm / 0.3 inch
Note the pin assignment for draw-wire displacement sensors with encoder output.
The sensor contains an additional supplement for detailed information.
For further information, please refer to the online documentation.
You will find the latest version at:
www.micro-epsilon.com/link/wire
> “wireSENSOR WDS-P60 / P96 Analogue“ or
“wireSENSOR WDS-P115 Analogue“.
Operation
Draw wire sensors with voltage output (U) or current output (I) are equipped
with integrated electronics with setting potentiometers (trimmers) for zero and
gain. The access holes for the trimmers are located in the housing cover. With
the zero trimmer the zero point can be shifted by ±20 % of the range with
voltage output (±18 % with current output). With the gain trimmer the signal
span (sensitivity) is adjusted by ±20 % with voltage output (±15 % with current
output). For draw wire sensors with encoder output (E, A) there are no adjust-
ment and setting elements.
Declaration of incorporation
Declaration of incorporation according to the EC Machinery Directive
2006/42/EC, Annex II B
Manufacturer and authorized representative for the compilation of the relevant
technical documents
MICRO-EPSILON MESSTECHNIK GmbH & Co. KG
Königbacher Straße 15, 94496 Ortenburg / Germany
hereby declares that the machine designated below, as a result of its manner
of design, construction as well as version that has been placed on the market
- to the extent possible in the scope of delivery - corresponds to the relevant,
fundamental health and safety requirements of the EC Machinery Directive,
including the valid changes at the time of this declaration.
Model: wiresensor
Type designation: WDS-xxx, WPS-xxx
The following fundamental health and safety requirements in accordance with
Annex I of the above-named directive are applied and maintained:
- No. 1.1.2. Principles of safety integration
- No. 1.7.3. Marking of machinery
- No. 1.7.4. Instructions
Furthermore, the compliance with the following standards is explained,
including the valid changes at the time of this declaration:
- EN ISO 13857 Safety of machinery - Safety distances to prevent hazard
zones being reached by upper and lower limbs
- EN 60204-1: 2006/A1: 2009 Safety of machinery - Electrical equipment of
machines - Part 1: General requirements
- DIN EN 61326-1: 2013
- DIN EN 61326-2-3: 2013
Moreover, we declare that the relevant technical documentation for this partly
completed machinery has been created in accordance with part B of Annex
VII, and that we shall be obligated to deliver these upon the request of the
market surveillance authorities.
The described partly completed machinery is intended for installation in a
production line.
The commissioning of this partly completed machinery shall be prohibited
until the partly completed machinery has been installed in a machine that
complies with the provision of the EC Machinery Directive and for which an
EC Declaration of Conformity in accordance with Annex II A is available.
Ortenburg, October 8th 2015 Dr. Thomas Wisspeintner
Managing Director
  • Page 1 1