  • Hello! I am an AI chatbot trained to assist you with the Whirlpool AKM 404/NB/01 Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
AKM 404 PRODUCT DESCRIPTION SHEET
FR
5019 319 61641
Operation of burners with electric
ignition
To light one of the burners:
Press the relative knob and turn it
anti-clockwise to the large flame and star
setting .
At the same time, keep the knob pressed against
the control panel until the burner ignites.
Once the burner is lit, keep the knob pressed
for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
cast iron griddles or terracotta pots and pans
heat diffusers such as metal mesh, or any
other types
two burners simultaneously for one
receptacle (e.g. fish kettle).
Operation of the electric hotplate
Set the knob to one of positions 1-6, which
correspond to different temperatures.
To switch off the hotplate, set the knob to
position “0”.
1. Removable panstand grids
2-5. Medium burners
3. Rapid electric hotplate
4. Large burner
6. Medium burner control knob
7. Large burner control knob
8. Medium burner control knob
9. Electric hotplate control knob
10. Pilot lamp for electric hotplate
Symbols
Shaded
circle
Tap closed
Large
flame and
star
Maximum opening/delivery
and electronic ignition
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
ELECTRIC HOTPLATE POWER: 1500 W.
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL
GAS
(Methane) G 20
large
medium
128
94
3.00
1.65
286 l/h
157 l/h
0.60
0.35
17 20 25
NATURAL
GAS
(Groningue) G 25
large
medium
128
94
2.78
1.53
308 l/h
170 l/h
0.60
0.35
20 25 30
LIQUID
PETROLEUM GAS
(Cylinder) G 30
large
medium
85
65
3.00
1.65
218 g/h
120 g/h
0.60
0.35
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G 31
large
medium
85
65
3.00
1.65
214 g/h
118 g/h
0.60
0.35
25 37 45
Type of gas used Appliance model Total rated
heat capacity
Pcs-kW
Total rated
consumption
Air required
for burning
m
3
/h
G 20 20 mbar 3 gas + 1 E 6.30 600 l/h 12.6
G 25 25 mbar 3 gas + 1 E 5.84 648 l/h 11.7
G 30 28-30 mbar 3 gas + 1 E 6.30 458 g/h 12.6