Whirlpool AKM 440/NB User guide

Category
Cookers
Type
User guide

This manual is also suitable for

Whirlpool AKM 440/NB is an electric hotplate that features 4 burners with electric ignition and an additional electric hotplate. The 4 burners include 1 large burner, 2 medium burners, and 1 small burner. The large burner has a power of 3.00 kW, the medium burners have a power of 1.65 kW, and the small burner has a power of 1.00 kW. The electric hotplate has a power of 1.50 kW. The device has a total rated heat capacity of 6.30 kW and a total rated consumption of 600 l/h. It requires a gas pressure of 20 mbar and an air supply of 11.7 m3/h for burning.

Whirlpool AKM 440/NB is an electric hotplate that features 4 burners with electric ignition and an additional electric hotplate. The 4 burners include 1 large burner, 2 medium burners, and 1 small burner. The large burner has a power of 3.00 kW, the medium burners have a power of 1.65 kW, and the small burner has a power of 1.00 kW. The electric hotplate has a power of 1.50 kW. The device has a total rated heat capacity of 6.30 kW and a total rated consumption of 600 l/h. It requires a gas pressure of 20 mbar and an air supply of 11.7 m3/h for burning.

AKM 439 PRODUCT DESCRIPTION SHEET
FR
5019 319 61881
Operation of burners with electric
ignition
To light one of the burners:
Press the relative knob and turn it
anti-clockwise to the large flame and star
setting .
At the same time, keep the knob pressed against
the control panel until the burner ignites.
Once the burner is lit, keep the knob pressed
for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The safety device of the burner shuts off the
gas supply to the burner if its flame goes out
accidentally (because of a sudden gust of
wind, an interruption in the gas delivery, the
overflowing of liquids, etc.).
Operation of the electric hotplate
Set the knob to one of positions 1-6, which
correspond to different temperatures.
To switch off the hotplate, set the knob to
position “0”.
Important
Improper use of the grids can result in damage to
the hob: do not position the grids upside down or
slide them across the hob.
Do not use:
cast iron griddles or terracotta pots and pans
heat diffusers such as metal mesh, or any
other types
two burners simultaneously for one
receptacle (e.g. fish kettle).
1. Removable panstand grids
2. Large burner
3. Rapid electric hotplate
4-5. Medium burners
6. Large burner control knob
7. Medium burner control knob
8. Medium burner control knob
9. Electric hotplate control knob
10. Pilot lamp for electric hotplate
Symbols
Shaded
circle
Tap closed
Large
flame and
star
Maximum opening/delivery
and electronic ignition
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be a minimum of 520 mm.
If the distance A between the wall cabinets is greater than the width of the
cooktop, the height B must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
ELECTRIC HOTPLATE POWER: 1500 W.
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL
GAS
(Methane) G 20
large
medium
128
94
3.00
1.65
286 l/h
157 l/h
0.60
0.35
17 20 25
NATURAL
GAS
(Groningue) G 25
large
medium
128
94
2.78
1.53
308 l/h
170 l/h
0.60
0.35
20 25 30
LIQUID
PETROLEUM GAS
(Cylinder) G 30
large
medium
85
65
3.00
1.65
218 g/h
120 g/h
0.60
0.35
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G 31
large
medium
85
65
3.00
1.65
214 g/h
118 g/h
0.60
0.35
25 37 45
Type of gas used Appliance model Total rated
heat capacity
Pcs-kW
Total rated
consumption
Air required
for burning
m
3
/h
G 20 20 mbar 3 gas + 1 E 6.30 600 l/h 12.6
G 25 25 mbar 3 gas + 1 E 5.84 648 l/h 11.7
G 30 28-30 mbar 3 gas + 1 E 6.30 458 g/h 12.6
G 31 37 mbar 3 gas + 1 E 6.30 450 g/h 12.6
  • Page 1 1
  • Page 2 2

Whirlpool AKM 440/NB User guide

Category
Cookers
Type
User guide
This manual is also suitable for

Whirlpool AKM 440/NB is an electric hotplate that features 4 burners with electric ignition and an additional electric hotplate. The 4 burners include 1 large burner, 2 medium burners, and 1 small burner. The large burner has a power of 3.00 kW, the medium burners have a power of 1.65 kW, and the small burner has a power of 1.00 kW. The electric hotplate has a power of 1.50 kW. The device has a total rated heat capacity of 6.30 kW and a total rated consumption of 600 l/h. It requires a gas pressure of 20 mbar and an air supply of 11.7 m3/h for burning.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI