Page 4 of 6 | 20221026
User Manual: Twin-line Central Foam Staon | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: CFS-TL
Operaon Instrucons:
1. Follow all instrucons from chemical manufacturer.
2. With the discharge trigger handle (PSG12) in the closed
posion, open the air inlet valve (BVB14) and soluon
inlet vavle (QFSOV14)
3. To start foaming, point discharge handle assembly at area
you wish to foam and squeeze the trigger handle (PSG12)
to begin foaming. Release the trigger handle to stop
foaming.
4. While the unit is running and discharging product, adjust
the needle valve (NV18, NV1032HNDL, NV1032SETS),
located inside the control box, as needed to regulate the
wetness or dryness of the foam following the steps below:
a. Close needle valve completely in clockwise direcon.
b. Open needle valve in counter-clockwise direcon 2
complete turns.
c. Connue to open needle valve in ¼ turn increments,
allowing 30 seconds between adjustments, unl
desired consistency of foam is achieved.
Aer Use Instrucons:
We recommend depressurizing the unit aer each use.
1. Close the discharge trigger handle (PSG12).
2. Shut o the air and soluon supply to the unit by closing
the air inlet valve (BVB14) and soluon inlet valve
(QFSOV14).
3. Open the discharge trigger handle to relieve any pressure
remaining in the system.
4. Close the discharge trigger handle aer all pressure has
been released from the unit. Store the unit with the
discharge trigger handle in the closed posion.
Maintenance Instrucons:
To keep your foam unit operang properly, periodically perform
the following maintenance procedures:
Note: Before performing any maintenance, ensure that the unit
has been depessurized according to the “Aer Use Instrucons.”
• Inspect hoses for leaks or excessive wear. Make sure all
hose clamps are in good condion and properly secured.
Troubleshoong Instrucons:
• Check to ensure that the discharge tubing has no kinks
that could obstruct uid ow.
• If foam discharge is inconsistent or sporadic, the needle
valve (NV18) and/or air regulator (R16) may be set
improperly. If this occurs, readjust the needle valve
(NV18) as described in Operaon Instrucons.
• Make sure proper foaming chemical and concentraon is
being used.
• If foam comes out wet, no maer where the needle valve
(NV18) is posioned, the check valve (CV14QF-S) may
need to be replaced.
• If the unit foams at a reduced pressure:
o Check the air compressor supplying the unit. If the
pressure is less than 40 psi, turn the foam unit o
unl the compressor can catch up.
o If the air supply to the unit is sucient, check the
air gauge (AG100) inside the control box. The
air pressure should be roughly equivalent to the
incoming soluon pressure.