  • Hello! I've reviewed the user manual for the F1.5L and F1.5LBK 1.5 liter pump-up foam units. I understand the instructions for operation, maintenance, and safety. I'm ready to answer any questions you have about its features, such as how to properly depressurize the unit, or the recommended temperature range for liquids used in the unit.
  • What is the liquid temperature range for the unit?
    What kind of chemicals can be used with this unit?
    How do I depressurize the unit?
    What should I do after using the unit?
USER
MANUAL
MODEL NUMBER:
F1.5L
F1.5LBK
and related units
1.5 Liter Pump-Up Foam Unit
English (Original Instrucons)
Page 2 of 5 | 01152018
User Manual: 0.4 gallon (1.5 liter) Pump-Up Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: F1.5L, F1.5LBK and related units
Read this manual completely and understand the
machine before operang or servicing it.
• Readallinstruconsbeforeinstallingoroperangunit.
• Alwayswearappropriatepersonalprotecveequipment
(PPE)whenoperangorservicingunit.
• Alwaysfollowallchemicalsafetyprecauonsand
handlinginstruconsprovidedbythechemical
manufacturerandSafetyDataSheet(SDS).
• Ifthisunitismodiedorservicedwithpartsnotlistedin
thismanual,theunitmaynotoperatecorrectly.
• Neverpointthedischargewandatyourself,another
person,oranyobjectyoudonotwantcoveredin
chemical.
• Neverleaveunitunaendedwhilepressurized.
• Alwaysdepressurizeunitbeforeaempngtoremove
thepumpassembly.
• Alwaysdepressurizeunitaeruse(asdescribedinthe
AerUseInstrucons).Alwaysstoreunitdepressurized.
• Donotpressurizeunitbyanymeansotherthanthebuilt-
inpumpassembly.
• Donotmodifyorremovepressurereliefvalve.Donot
useunitifpressurereliefvalveisnotoperaonal.
• Alwaysushtheunitwithfreshwaterwhenswitching
fromanalkalinetoanacidoranacidtoanalkaline.
• Alwayscarryunitbythecarryinghandle.Neverlior
carrytheunitbythepumphandleorthewand.
• Neveruseunitwithhydrocarbonsorammable
products.
• Donotexceedauidtemperatureof100˚F(37˚C).
WARNING
PROTECT THE ENVIRONMENT
Pleasedisposeofpackagingmaterials,oldmachine
components,andhazardousuidsinanenvironmentallysafe
wayaccordingtolocalwastedisposalregulaons.
Alwaysremembertorecycle.
*Specicaonsandpartsaresubjecttochangewithoutnoce.
REQUIREMENTS
Liquidtemperature
range
40-100˚F(4.4-37˚C)
Chemicalcompability Chemicalproductsusedwiththis
equipmentmustbeformulated
forthistypeofapplicaonand
compablewithunitmaterialsand
pumpseals.Formoreinformaon
onchemicalcompability,consult
themanufacturerorSDSforyour
productorcontactourcustomer
servicedepartment.
SPECIFICATIONS
Powertype Manual
Chemicalpickuptype Drawsfrompre-mixedsoluon
Numberofproducts
unitcandrawfrom
Oneproduct
OperangCapacity 0.3gallon(1.1liter)
Dischargewand/p
type
Polypropylenetriggerhandlewith
110degreefanp
Outputdistance 1-2(0.3-0.6m)
Pumpseals Viton
Page3of5|01152018
User Manual: 0.4 gallon (1.5 liter) Pump-Up Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: F1.5L, F1.5LBK and related units
Operaon Instrucons:
1. Ensureallairpressureisreleasedfromunitbyacvang
thepressurereleasevalve(locatedonthesideofthe
pumpassembly(PA-F1.5L)).
2. Securelyholdtheunitandunscrewthepumpassembly
(PA-F1.5L)fromthetankinacounter-clockwisemoon.
3. Followallinstruconsfromchemicalmanufacturer.Fill
tank3/4ofthewaywithpre-mixedsoluon.
(Note:Donotoverlltankwithsoluon.)
4. Securelyholdthetankandscrewthepumpassembly(PA-
F1.5L)backoninaclockwisemoon.
5. Pressurizethetankbypumpingapproximately20to25
mes,orunlitbecomediculttopump.(Note:The
pressurereliefvalvewillleakiftheairpressureistoohigh.
Donotoverlltankwithair.)
6. Tostartfoaming,pointthewandassemblyattheareayou
wishtofoamandpressdownontheOn/Ocontrolto
dischargefoam.ReleaseOn/Ocontroltostopfoaming.
7. Fordrainapplicaons,posiondrainaachmentoverthe
drainorinsertplugintodrain.Tostartfoaming,pointthe
wandassemblyattheareayouwishtofoamandpress
downontheOn/Ocontroltodischargefoam.Release
On/Ocontroltostopfoaming.
Aer Use Instrucons:
1. Releaseairpressurefromunitaereachusebyacvang
thepressurereleasevalve(locatedonthesideofthe
pumpassembly(PA-F1.5L)).
2. Itisrecommendedtoalwaysemptyoutremaining
soluonandrunfreshwaterthroughtheunittorinseall
partsthoroughlyaereachuseandbeforestorage.
Maintenance Instrucons:
Warning: Always depressurize unit before performing
maintenance.
Tokeepyourunitoperangproperly,periodicallyperformthe
followingmaintenanceprocedures:
• Checkthepumpassemblyforwearandleaks.
• Checkthesucontubeandscreenfordebrisandcleanas
needed.
• Replacewadding(WD-F1.5L)insidedischargewandas
needed.Replacewaddingbyfollowingstepsbelow:
1. Removethedischargewandbyunthreadingretaining
nut(WA-1.5L-RN).
2. Removethewadding(WD-F1.5L)insidethedischarge
wandanddiscard.
3. Insertnewwaddingdisksinsidethedischargewand.
4. Threadtheretainingnutbackon.Makesurethe
o-ring(WA-1.5L-OR)isinplace.
• Periodicallylubricatethepumpsealwithafoodsafe
lubricants.Tolubricatethepumpseal,raisepumphandle
andapply5to10dropsoffoodsafelubricantbetween
pumpandpumpsleeve.NEVERUSELUBRICANTSSUCH
ASWD40.
Page 4 of 5 | 01152018
User Manual: 0.4 gallon (1.5 liter) Pump-Up Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: F1.5L, F1.5LBK and related units
PUMP ASSEMBLY
ITEM NUMBER: PA-F1.5L
WAND ASSEMBLY:
ITEM NUMBER: WA-F1.5L
WA-1.5L-RN
WD-F1.5L
STB-F1.5L
WA-1.5L-OR
PW-1.5L
TANKS
ITEM NUMBERS: TANK1.5L, TANK1.5LBK
TANK1.5L (white tank)
TANK1.5LBK (black tank)
Liquid level viewing stripe
Pressure relief valve
On/off
WA-F1.5L
PST-F1.5L
Exploded View
Page 5 of 5 | 01152018
User Manual: 0.4 gallon (1.5 liter) Pump-Up Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model Number: F1.5L, F1.5LBK and related units
DHB3814
WD-F1.5L
WA-1.5L-RN
WA-1.5L-OR
PW-1.5L
H14C
RMS2
HM1414
ITEM NUMBER DESCRIPTION
DHB3814 3/8FLATSEAT1/4HOSEBARB
H14C 1/4inIDCLEARPOLYVINYLTUBING-Availableper.(3/8
inOD)
HB1414 1/4inMPTX1/4inHOSEBARB
HM1414 HOSEMENDER-1/4inchBARBX1/4inchBARB
PA-F1.5L PUMPASSEMBLYFOR1.5LFOAMUNIT
PW-1.5L POLYWANDFOR1.5LPUMPUP
RDC12 RUBBERDRAINCUPFOR1/2INCHBARB
ITEM NUMBER DESCRIPTION
RMS2 RUBBERMOLDEDSTOPPER-SIZE#2-EPDM
STB-F1.5L BUTTONSPRAYTIPFOR1.5LPUMPUP
TANK1.5L 1.5LTANK-WHITE
TANK1.5LBK 1.5LTANK-BLACK
WA-1.5L-OR O-RINGFOR1.5LWANDASSEMBLY
WA-1.5L-RN RETAININGNUTFOR1.5LWANDASSEMBLY
WD-F1.5L WADDINGDISKFOR1.5LPUMPUP(1PIECE)
ITEM NUMBER: WA-F1.5L-DP.75
ITEM NUMBER: WA-F1.5L-DP3.75
DHB3814
WD-F1.5L
WA-1.5L-RN
WA-1.5L-OR
PW-1.5L
H14C
RDC12
HB1414
FOR UNITS WITH DRAIN ATTACHMENTS:
/