Montigo Finishing around a Power COOL-Pack equipped fireplace Operating instructions

Category
Fireplaces
Type
Operating instructions
Finishing Around a Montigo Fireplace
The following pages provide finishing options for your Montigo
fireplace equipped with the Power COOL-Pack option.
Outer Glass
A
FIGURE 1: Typical Montigo Fireplace Cross Section.
See following figures for enlarged finishing detail of “A”
Finishing with a NON-Combustible Material
If the finish for the Power COOL-Pack equipped fireplace will be
of a non-combustible material, such as stone or tile, please refer
to Figure 2.
Glass
Material MUST NOT
extend past the edge
Combustible
Material /Drywall
Steel header or non-
combustible framing
member
Non-Combustible facing
material /Stone or Tile
DETAIL A: Finishing with Non-Combustible Material such
as Stone or Tile
Non-Combustible
Material /Cement Board
3
min
FIGURE 2: Detail of A - Finishing with Non-Combustible
Finishing With a Combustible Material
If the finish for the Power COOL-Pack equipped fireplace will be
of a combustible material such as wood laminate, please refer to
Figure 3.
Glass
Non-Combustible
Material / Cement board
Material MUST
NOT extend past
the edge
Combustible
Material /Drywall
Steel header or non-
combustible framing
member
Combustible
Finishing Material
DETAIL A: Finishing with Combustible Material such as Wood
Laminate. Same detail applies to sides. No non-combustible
required below glass.
6
FIGURE 3: Detail of A - Finishing with Combustible
A
Finishing a Power COOL-Pack Equipped Montigo Fireplace
www.montigo.com
Finishing with a Painted Finish
If the finish for the Power COOL-Pack equipped fireplace will be
a painted finish, please refer to Figure 4.
Glass
Non- Combustible
Material /Cement
board
Material MUST NOT
extend past the edge
Combustible
Material /Drywall
Steel header or non-
combustible framing member
6”
min
DETAIL A: Finishing with Drywall/ Cement Board
for a Painted Finish
FIGURE 4: Detail of A - Finishing with painted finish
A Note on Mantels & Surrounds
National Canadian Gas Association mantel test requirements are
for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands
for the wise use of energy, has prompted us to manufacture many
models of fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above
normal room temperature and walls above the fireplace may be
hot to touch.
We recommend careful consideration be given to the effects of
elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic, or pictures. This elevated
heat can cause melting, deformation, discoloration or premature
failure of a TV and radio components.
Finishing: Mantels and Surrounds
Combustible mantels may safely be installed over the fireplace
provided that they do not project beyond the shaded area shown
in Figure 5:
FIGURE 5: Combustible Mantel Clearances
Combustible Construction
allowed in shaded area.
Non-Combustible Framing
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
12 11 10 9 8 7 6 5 4 3 2 1
Finishing a Power COOL-Pack Equipped Montigo Fireplace