Geovision GV-IO 12-in card V3 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Geovision GV-IO 12-in card V3 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
2013.12.23
With 12 digital inputs, the GV-IO 12-In Card is designed to work with the GV-NET/IO
Card to provide an interface for your external devices such as sensors and detectors.
Installation
Insert the GV-IO 12-In Card to an empty card slot. Connect the 20-Pin Ribbon Cable
to the GV Video Capture Card, the GV-IO 12-Out Card, and the GV-NET/IO Card as
shown below.
1
2
20-Pin Ribbon Cable (4 Connectors) x 1
GV-IO 12-In Card x 1
Packing List
12
ECE
3
ON
GV Video Capture Card
Input 5
Input 6
Input 7
Input 8
Ground
OFF
Wet Contact
ON
GV-IO 12-In Card
1
12
ECE
3
ON
12
ECE
3
ON
Dry Contact
20-pin Ribbon Cable
2
Connect to
GV-NET/IO Card and
GV-IO 12-Out Card
3
4-Pin to 4-Pin Mini Power Cable x 1
Input 13
Input 14
Input 15
Input 16
Ground
Input 9
Input 10
Input 11
Input 12
Ground
4-pin to 4-pin
Mini Power Cable
3
4
Installation Guide x 1
Specifications
All GV Video Capture Cards
Dry Contact
12
Input
Input Signal
Input
Environmental Conditions
0~50 Degree C / 32~122 Degree F
5%~95% (Non-Condensing)
Compatible Card
Models
Note:
1. Use of DIP Switch:
a. Use the switch for dry contact and 9-30V wet contact.
b. The card allows the use of mixing dry and wet contact devices
together. (Default Setting: Dry Contact)
c. The 12 inputs divided as four-in-one groups are related to the three
switches on the card for dry and wet contact.
2. To prevent the noise interference in I/O operation, tightly screw the
GV-IO 12-In Card to the PC case.
3. The GV-IO 12-In Card must work with the GV-NET/IO Card together.
Dimensions (W x H) 90 x 99 mm / 3.54 x 3.9 in
DC IN DC 5V, 1A
Wet Contact: 9~30V AC/DC
GV-IO 12-In Card V3
/