8
Installation BAT-F
Release
18
07/2020
Indoor operator access area:
The location is accessible without tools.
The person responsible for the area has provided access for the
operator intentionally.
The operator knows of the access possibilities, regardless of whether
they need a tool.
If all the following requirements are fulfilled, you have the option of
installing the device in the indoor operator access area.
You supply 24 V DC to 48 V DC SELV voltage to the device.
You install the device inside a building.
The surrounding air temperature is 140 °F (60 °C).
Applies exclusively for Finland, Norway, and Sweden:
You supply Power over Ethernet (PoE) to the device, with the PoE
data cable laid inside a building exclusively.
In any case, install this device in a switch cabinet or in an operating
site with restricted access, to which maintenance staff have exclusive
access if 1 of the following requirements is fulfilled:
You supply 60 V DC to 250 V DC or 110 V AC to 230 V AC to the
device.
You install the device outside a building.
The surrounding air temperature is > 140 °F (60 °C).
Applies exclusively for Finland, Norway, and Sweden:
You supply Power over Ethernet (PoE) to the device, with the PoE
data cable laid outside a building or between buildings.
Applies to device variants featuring supply voltage with characteristic
value K: (60 V DC ... 250 V DC / 110 V AC ... 230 V AC, 50 Hz ...
60 Hz):
See “Device name and product code” on page 27.
Install this device only in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Install the device in the vertical position, with the antenna connections
pointing upwards.
At ambient air temperatures > 140 °F (+60 °C):
The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
Qualification requirements for personnel
Only allow qualified personnel to work on the device.