Maxxima MEW-SC100W-02 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Maxxima MEW-SC100W-02 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Note: For Separate Feed wiring, the break-o-n located between the dark-colored screws should be removed before
wiring. Use a Flat Head to bend then unl it breaks o.
Two Single Pole Switches with Terminal screws.
15A 60Hz 120VAC
– 1800W Max - Separate Feed wiring Capable.
Caution:
Break-off-fin should only be removed for Separate Feed (2 circuit) installation.
1. Shut off power at the circuit breaker or fuse. See Warning.
2. Remove insulation from wires (approximately 3/8" to 5/8"). The HOT terminals have the dark colored
screws. Loop each wire around their respective terminal screw per the diagram below.
3.
Fasten Screws securely. Terminal screws accept up to #12AWG copper or copper clad wire
4.
Mount the switch using the long mounting screws provided. Attach wall plate.
5. Restore power at the circuit breaker or fuse. See Warning.
Maxxima extends a 1 year limited warranty to the original purchase that this product is free from
defects in material and/or workmanship only. Maxxima will replace any warranted product to the
original
consumer/purchaser if the product fails because of defects due to workmanship and/or
materials within the limited warranty period. Limited warranty is not transferable and applies to the
original installation of the Maxxima product. This offer does not constitute in any way a product
guarantee and Maxxima does not hereby assume any obilgation whatsoever beyond sending a free
replacement product
MEW-SC200W
Single Pole Combination Switch
WARNING
To avoid fire, shock, or death, TURN OFF POWER at circuit breaker or fuse and test that power
is off before wiring! - Use only with copper or copper clad wire -
SPECIFICATION
INSTALLATION
WARRANTY INFORMATION
Common Feed: The two
single pole switches wired
to one HOT circuit.
Separate Feed: Two single
pole switches on separate
circuits. (Break off fin
removed)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Hot
Hot
Hot
Neutral
Neutral
Break o n
location
WARNINGS
/