AK200126113 (121)
Warranty Conditions
The Aqua-Pure
®
AP9200
+
Water Filter System is designed to operate at a maximum pressure of 862kPa (125psi) and at a maximum temperature of 38°C. 3M Purifi cation Pty Limited (“3M”) warrants this fi lter system
to be free from defects in material and workmanship for a period of one year from the date of purchase (*warranty period does not apply to cartridge which is a consumable). This warranty is expressly limited to the
repair or replacement at our premises of any part or parts proving defective providing the housing has been installed by a licensed plumber in accordance with our installation instructions and all relevant plumbing codes,
the installation of an approved pressure limiting device preceding the fi lter, and the pressure and temperature do not exceed the limits stated herein. This warranty does not extend to mechanical damage caused during
installation or use. To claim under this warranty contact 3M Purifi cation on 1300 345 837.
This warranty only applies to 3M Purifi cation Customers who purchase the Aqua-Pure
®
AP9200
+
Water Filter System sold by 3M Australia.
This warranty is provided in addition to other rights and remedies you may have under law: Our goods come with guarantees which cannot be excluded under the Australian Consumer Law. You are entitled to replacement
for a major failure and to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. This warranty is given by 3M Purifi cation Pty Limited, ABN 28
003 075 812, Building A, 1 Rivett Road, North Ryde NSW 2113, Ph 1300 345 837.
PERFORMANCE DATA SHEET AQUA-PURE
®
CARTRIDGE
Model: AP9250 Stage 1 & 2 Replacement Cartridges for AP9200
+
This system has been tested according to NSF/ANSI Standard 42 and / or AS/NZS 4348 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system as specifi ed in NSF/ANSI Standard 42 and / or AS/NZS 4348.
Substance Average Infl uent Infl uent Challenge NSF / ANSI Guidelines Avg. Product Water Average Reduction % Status
Concentration Concentration Units Concentration
apply to each row
Chlorine
Taste and Odour
Cyst
Application Guidelines / Water Supply Parameters
Capacity 2,839 litres
Service Flow 2.8 lpm
Water Pressure 172-862 kPa (25-125 psi)
Water Temperature 4.4 ºC - 38 ºC
Testing Condition: pH: 7+/-1 | Temp: 20+/-5 Celsius | Pressure: 600 kPa +/- 100 kPa
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
System must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines. Failure
to do so may void warranty. See warranty card for details.
CAUTION: This fi lter system or cartridge is designed to be installed on the cold water line. Do not install on hot water line.
WARNING: AS3497:1998 requires dual backfl ow prevention and certifi ed pressure control device to be installed prior
to fi lter system(s) that are plumbed into mains water supply. Failure to do so will not only void all warranty(s) on the fi lter
system(s), but will put the home at risk of fl ooding in the event of damaged appliances during pressure surges.
CAUTION: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certifi ed for cyst reduction may be used on disinfected water that may contain fi lterable cysts.
To reduce the risk associated with property damage due to water leakage:
• Read and follow instructions before installation and use of this system
• Installation and use must comply with existing state or local plumbing codes
• Protect fi lter from freezing. Drain fi lter when room temperature drops below 4.4ºC
• Contact plumbing professional if you are uncertain how to check your water pressure
• Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer
arrester. Contact a plumbing professional if you are uncertain how to check for this condition
• Install on cold water lines only. Do not install on hot water supply lines. The maximum operating water temperature of this fi lter
system is 38 ºC
• The disposable fi lter cartridge must be replaced every 12 months or at the specifi ed service cycle
• Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation (waste baskets,
etc.)
!
NOTE: Aqua-Pure
®
fi lter systems are designed for ease of
installation. However, post-installation inspections are highly
recommended. Check for leaks immediately after installation
and once again after 24 hours. If leaks are detected, turn off
water supply, drain water and inspect the leaks. If problems
persists, contact the installer / plumber for rectifi cation.
It is essential that operational, maintenance and fi lter
replacement requirements be carried out for this product to
perform as advertised.
Flush new cartridge for at least 2 minutes to remove trapped
air bubbles.
If left unused for more than 24 hours, fl ush cartridge for 2
minutes before use.
2.125 mg/L 2.0 mg/L + 10% ≥ 50.00% 0.184 mg/L 96.02 PASS
6.25 x 10
4
/mL 6.25 x 10
4
/mL ≥ 99.90% 26 / ml 99.96 PASS