Cooper Lighting HB User manual

  • Hello! I am an AI chatbot trained to assist you with the Cooper Lighting HB User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
COOPER LIGHTING - LUMARK
®
INDUSTRIAL
527
COOPER LIGHTING
DIMENSIONS
Easy slide-on die-cast
aluminum mounting box
with tapped opening for
3/4" conduit
Durable heavy-duty
die-cast aluminum
housing for lasting
performance in the
harshest environments.
Integrally hinged for
ease of maintenance with
optional toolless entry.
Finished in a standard
white polyester powder
paint
High power factor ballast
with class H insulation.
ECON
TM
electronic
ballast technology
delivers longer lamp life
and improved lumen
output while maintaining
a constant lamp wattage.
Minimum starting
temperature is -40°C
(-40°F) for HPS and
-30°C (-20°F) for MH
Universal ladder brackets
allow for the flexibility to
change out with other
reflectors / refractors
available in aluminum or
glass
Mogul-base porcelain
socket
Easily mounted prismatic
acrylic refractor has
multiple field-adjustable
distribution patterns for
precision control
Approximate net weight:
37 lbs. (17 kgs.)
DESCRIPTION
The BenchMark HB prismatic
high-bay utilizes a durable
heavy-duty die-cast aluminum
ballast housing and prismatic
acrylic reflector for maximum
durability and photometric
performance. U.L. listed and
CSA certified. Damp location
standard.
The BenchMark HB prismatic
high-bay is perfect for retail
stores, wholesale warehouses,
grocery chains, malls and
auto showrooms.
HB
16", 22" & 25"
PRISMATIC
BENCHMARK
175-1000W
High Pressure Sodium
Pulse Start Metal
Metal Halide
HEAVY-DUTY
PRISMATIC HIGH-BAY
INDUSTRIAL LUMINAIRE
16" [406mm]
22" [559mm]
25" [635mm]
Maximum Height is
16"=27 15/16" [710mm]
22"=30 7/16" [773mm]
25"=31 5/8" [803mm]
See ordering information
for details
NOTES: 1 Not available in 175, 200, 320, 350, 450 and 750W. 2 Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC
code requires that open luminaires must utilize a safety glass bottom (SGB) accessory or an Open rated socket (OR) and lamp. 3 175, 200, 250, 320, 350 & 400W
only. 4 277V only, not available with HSW, HL or HC options. 5 “MD” option available on PD22 and PD25 with 250, 320, 350 or 400W Pulse Start Metal Halide
only. 6 MD available in 208, 240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz. 7 Factory set for concentrated, medium or wide
distributions only if P (factory pre-set) is in the nomenclature of the fixture. 8 HPS only. 9 Products also available in non-US voltages and 50Hz for international
markets. Consult factory for availability and ordering information. 10 Multi-tap ballast 120/208/240/277V wired 277V. 11 Triple-tap ballast 120/277/347V wired
347V. 12 5-tap ballast 120/208/240/277/480V wired 480V. 13 Add as suffix in the order shown. 14 Specifications and dimensions subject to change without notice.
Powered by
technology
ORDERING INFORMATION
SAMPLE NUMBER: HPHB-PD16-M-250-MT-Q
Lamp Type
HP=High
Pressure
Sodium
1
MH=Metal Halide
2
MP=Pulse Start MH (CWA)
2
ML=Pulse Start MH (Linear Reactor)
2, 3, 4
MD=Pulse Start Metal Halide (Electronic)
2, 5, 6
Series
HB=High-Bay
BenchMark
Refractor Type
PD=Prismatic
Acrylic
Refractor
Diameter
16=16"
22=22"
25=25"
Socket Position/
Distribution
7
C=Concentrated
M=Medium
W=Wide
Lamp
Wattage
175=175W
200=200W
250=250W
320=320W
350=350W
400=400W
450=450W
600=600W
8
750=750W
1000=1000W
Voltage
9
120V
208V
6
240V
6
277V
6
347V
480V
MT=Multi-Tap
10
TT=Triple-Tap
11
5T=5-Tap
12
E=Electronic
6
Options &
Accessories
13
(See Pages 541-545)
% Lamp Survival
LAMP MORTALITY
2000 4000 6000 10000 8000 12000 14000 16000 18000 20000 22000 24000 26000 28000 30000
0
90
80
70
60
50
40
30
20
10
0
100
Lamp Life [Hours]
Natural White & Uni-Form Pulse Start on ECON TECHNOLOGY Uni-Form Pulse Start on CWA Probe Start Metal Halide on CWA
TM ® ®
% Lumens
LUMEN MAINTENANCE
2000 4000 6000 10000 8000 12000 14000 16000 18000 20000
40
90
80
60
70
50
0
90% Mean Lumens Nat-Wt-ECON 86% Mean Lumens-UPS-ECON 75% Mean Lumens-UPS CWA
65% Mean Lumens-Probe Start
100
Lamp Life [Hours]
LAMP MORTALITY AND LUMEN MAINTENANCE COMPARISONS
NOTE: Lamp Mortality and Lumen Maintenance Charts Courtesy of VENTURE
®
Refractor Lamp
Type Wattage
105°C
40°C (ECON)*
55°C (Open) or
40°C (Enclosed)**
Supply
Wire (Min.)
Ambient
Environment
PD16 175-400W
PD22 175-450W
PD25 400-1000W
NOTES: * Electronic Pulse Start Metal Halide.