WIRING DIAGRAM
WME-8
Rev.00#891-00416
VOLTAGE
SELECTOR
115/230 VAC
230V
L1 L2/N12
COMM
+12-+34-+56-+78-
GND
L1
L2
(N)( N )
230 VAC (115 VAC)
WME-8
POWER SUPPLY
{
WME-8
ON
OFF
ID #
NO
END OF
LINE JUMPER *
YES
INPUT 2
INPUT 1
INPUT 4
INPUT 3
INPUT 6
INPUT 5
INPUT 8
INPUT 7
COMMUNICATION
TERMINALS
TEMPERATURE
CONTROLLER
WATER METER:
The water meter output should
be a dry contact and should
not pulse faster than 60 times
a second (60 Hz).
A 22/12 AWG gauge cable no
longer than 2000 feet (0.6 km)
can be used to connect the
water meter. Do not use a cable
longer than 2000 feet even
if a larger cable is used.
DO NOT RUN THE
METER CABLE OUTSIDE
THE BUILDING!!
Set the End of Line (EOL)
jumpers to “Yes” on the first and
on the last device of the
communication line.
EOL = NO EOL = YES
INPUTS:
Inputs 1-8 = 60 Hz max
END OF LINE
IDENTIFICATION
DO NOT DRILL THE SIDES
OF THE UNIT CONTROL.
USE AVAILABLE KNOCK
OUTS AT THE BOTTOM OF
THE UNIT.
Rev.00