Munters CC247 Elite Product information

Type
Product information
1 2 31 2 3
1 2
PC
ID #4-13
1 2
COMM
1 2
1 2 3
COMM
ID #16
ON
OFF
ID #3
ID #2ID #17 ID #1
ON
OFF
ON
OFF
1 2
GND
COM
ON
OFF
NO
YES
NO
YES
NO
YES
1 2
GND
COM
1 2
GND
COM
T∞ T∞ T∞ T∞ T∞ T∞ T∞ T∞
T∞
NC NOC
ALARM
+ 1 2 1 1 3
- - - 2 2 4
14VDC 0-10V PC MODULES
{
3
-
4
-
SH
SH
L1 L2/N
POWER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
- - - - - - - - - - - - - - - -
SENSOR INPUTS
17 18 19 20 21 22
- - - - - -
{
OUT
GND
L1
L2
( N )
PC
1
2
3
230 V
CC24-7 ELITE
{
[0-10V "-"] →
[0-10V "-"] →
[0-10V "-"] →
[0-10V "-"] →
[0-10V "4"] →
[0-10V "3"] →
[0-10V "2"] →
[0-10V "1"] →
[11] →
[10 + ] →
[10
- ] →
[14VDC +] →
[14VDC +] →
[14VDC -] →
← [MODULE 3]
← [MODULE 4]
← [MODULE 2]
ON
OFF
WIRING DIAGRAM
CC24-7 ELITE
#891-00003 Rev.10
Inside Probe 1
Inside Probe 2 (opt.)
Inside Probe 3 (opt.)
Inside Probe 4 (opt.)
Inside Probe 5 (opt.)
Inside Probe 6 (opt.)
Inside Probe 7 (opt.)
Inside Probe 8 (opt.)
Outside Probe (opt.)
Message
center input
Feeder
Water
meter 2 (opt.)
Water
meter 1 (opt.)
0-10V
Load 1
115/230Vac
Voltage selection
switch
J10 Memory card
connector
PC PORT: Insert an “Enabler”
card to use the ABOX or insert a
Comlink-1 card to use Agnet (see
overleaf).
Control
Power Supply
85 to 250 Vac
Alarm
Supply
Internal Static
Pressure sensor
Relay Panel CS
Inside humidity
sensor (optional)
To communication system (see overleaf)
0-10V
Load 2
0-10V
Load 3
0-10V
Load 4
Connect the
controller to a
15A breaker !
Water module
(optional)
End of line=No
(see note 7 below)
End of line=No
(see note 7 below)
End of line=No
(see note 7 below)
End of line (EOL) =Yes
(Set the EOL jumper to “No” only if
additional devices follow the relay
panel on the communication line.
See note 7 below.)
End of line=No
(see note 7 below)
End of line=Yes
(see note 7 below)
End of line=Yes
(see note 7 below)
Air inlet module
8
(optional)
Variable Outputs
(inside VSM-2 or inside
RP-2V16 module)
Wiring Diagram when using a RELAY PANEL CS
(Relay panel with 2 “MODULE” terminals)
Installation Notes:
1. Mounting Instructions: Leave a clearance of at least
16(400 mm) to the left of the controller box to allow
the cover to be removed for maintenance.
2. Cable Entry: Punch holes at the bottom of the enclosure
to allow wires to be introduced in the controller. Do not drill
the top or side panels of the enclosure.
3. Alarm System: Installation of a good quality alarm system
is strongly suggested to warn of power failures and high/low
temperatures.
4. Surge Protection: Provide a surge protection (including light-
ning protection) from the power supply to the controller and
from the control to the sensors. Consult a certified electrician
if required.
5. Low Voltage Wires: Install low voltage wires (probes &
0-10V loads) at least 12 inches (300 mm) away from high
voltage wires (230-120VAC,24Vdc). Always cross low and
high voltage wires at a 90° angle.
6. Water Meter: The water meter output should be a dry
contact and should not pulse faster than 60 times a second
(60Hz). A 22/12 AWG gauge cable no longer than 2000 feet
(0.6 km) can be used to connect the water meter. Do not use
a cable longer than 2000 feet even if a larger cable is used.
Do not run the meter cable outside the building!!
7. End of Line Jumper (EOL):
Set the end of line jumper to the
“Yes” position on the first and
last device of the communica-
tion line.
2-3=Yes
1-2=No
Relay Panel CS ID Numbers
8. Air Inlet ID Numbers: Position the black jumpers properly
on the Comlink card of each inlet to assign the inlet’s ID num-
ber. Assign inlet ID in numerical order starting with ID#4.
9. Relay Panel ID Assignment (for RP-16, RP-32 & RP-48
only): Each group of 16 relays is linked with a communication
board. Up to 3 different communication boards can be located
inside a relay panel and each board must be given a unique
identification number so the controller can communicate with
it. Refer to the “RELAY PANEL ID NUMBER” table above to
assign these number properly.
Comm.Board 3 Comm.Board 2 Comm.
Board 1
ID assignment for RP- 8 /16 / 32 / 40 / 48
Comm.
Board 1
Relays
1-16
ID #1
Comm.
Board 2
Relays
17-32
ID #2
Comm.
Board 3
Relays
33-48
or
33-40
ID #17
Comm.
Board 4
Relays
49-64
ID #18
Comm.
Board 5
Relays
65-80
ID #19
Comm.
Board 6
Relays
81-96
ID #20
ID assignment for RP-50
Comm.
Board 1
Relays
1-50
ID #1
1 2 31 2 3
1 2
PC
ID #4-13
1 2
COMM
1 2
1 2 3
COMM
ID #16
ON
OFF
ID #3
ON
OFF
T∞ T∞ T∞ T∞ T∞ T∞ T∞ T∞
T∞
NC NOC
ALARM
+ 1 2 1 1 3
- - - 2 2 4
14VDC 0-10V PC MODULES
{
3
-
4
-
SH
SH
L1 L2/N
POWER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
- - - - - - - - - - - - - - - -
SENSOR INPUTS
17 18 19 20 21 22
- - - - - -
{
OUT
GND
L1
L2
( N )
PC
1
2
3
230 V
CC24-7 ELITE
{
[0-10V "-"] →
[0-10V "-"] →
[0-10V "-"] →
[0-10V "-"] →
[0-10V "4"] →
[0-10V "3"] →
[0-10V "2"] →
[0-10V "1"] →
[11] →
[10 + ] →
[10
- ] →
[14VDC +] →
[14VDC +] →
[14VDC -] →
ON
OFF
← [MOD.3]
← [MOD.2]
21 3 4 SH
WIRING DIAGRAM
CC24-7 ELITE
#891-00003 Rev.10
Inside Probe 1
Inside Probe 2 (opt.)
Inside Probe 3 (opt.)
Inside Probe 4 (opt.)
Inside Probe 5 (opt.)
Inside Probe 6 (opt.)
Inside Probe 7 (opt.)
Inside Probe 8 (opt.)
Outside Probe (opt.)
Message
center input
Feeder
Water
meter 2 (opt.)
Water
meter 1 (opt.)
0-10V
Load 1
115/230Vac
Voltage selection
switch
J10 Memory card
connector
PC PORT: Insert an “Enabler”
card to use the ABOX or insert a
Comlink-1 card to use Agnet (see
overleaf).
Control
Power Supply
85 to 250 Vac
Alarm
Supply
Internal Static
Pressure sensor
Relay Panel
Inside humidity
sensor (optional)
To communication system (see overleaf)
0-10V
Load 2
0-10V
Load 3
0-10V
Load 4
Connect the
controller to a
15A breaker !
Water module
(optional)
End of line=No
(see note 7 below)
End of line=No
(see note 7 below)
End of line=Yes
(see note 7 below)
End of line=Yes
(see note 7 below)
Air inlet module
8
(optional)
Variable Outputs
(inside VSM-2 or inside
RP-2V16 module)
ID Number
(see note 9 below)
MODULE
Wiring Diagram when using a non-CS Relay Panel
(Relay panel with 5 “MODULE” terminals)
Installation Notes:
1. Mounting Instructions: Leave a clearance of at least
16(400 mm) to the left of the controller box to allow
the cover to be removed for maintenance.
2. Cable Entry: Punch holes at the bottom of the enclosure
to allow wires to be introduced in the controller. Do not drill
the top or side panels of the enclosure.
3. Alarm System: Installation of a good quality alarm system
is strongly suggested to warn of power failures and high/low
temperatures.
4. Surge Protection: Provide a surge protection (including light-
ning protection) from the power supply to the controller and
from the control to the sensors. Consult a certified electrician
if required.
5. Low Voltage Wires: Install low voltage wires (probes &
0-10V loads) at least 12 inches (300 mm) away from high
voltage wires (230-120VAC,24Vdc). Always cross low and
high voltage wires at a 90° angle.
6. Water Meter: The water meter output should be a dry
contact and should not pulse faster than 60 times a second
(60Hz). A 22/12 AWG gauge cable no longer than 2000 feet
(0.6 km) can be used to connect the water meter. Do not use
a cable longer than 2000 feet even if a larger cable is used.
Do not run the meter cable outside the building!!
7. End of Line Jumper (EOL):
Set the end of line jumper to the
“Yes” position on the first and
last device of the communica-
tion line.
2-3=Yes
1-2=No
ID assignment for RP- 8 /16 / 32 /48
Comm.
Board 1
Relays
1-16
ID #1
Comm.
Board 2
Relays
17-32
ID #2
Comm.
Board 3
Relays
33-48
ID #17
Comm.
Board 4
Relays
49-64
ID #18
ID assignment for RP-50
Comm.
Board 1
Relays
1-50
ID #1
Comm.
Board 1
Relays
51-100
ID #2
Relay Panel ID Numbers
8. Air Inlet ID Numbers: Position the black jumpers properly
on the Comlink card of each inlet to assign the inlet’s ID num-
ber. Assign inlet ID in numerical order starting with ID#4.
9. Relay Panel ID Assignment (for RP-16, RP-32 & RP-48
only): Each group of 16 relays is linked with a communication
board. Up to 3 different communication boards can be located
inside a relay panel and each board must be given a unique
identification number so the controller can communicate with
it. Refer to the “RELAY PANEL ID NUMBER” table above to
assign these number properly.
AgNet Communication System Hook-up (optional)
A-BOX Communication System Hook-up (optional)
7654321
1 2 3 4 Tx Rx G
L N
G
Modem or
Computer
Modem or
Computer
Bridge-A
Red
Green
White
SureLink-2 Module
A B
GND
A B
GND
Red
Black
Shield
A
Connector A
Main Control
Main Control
PC
PC
Enabler card
* Refer to the Surelink
manual to set the end
of line jumpers (EOL)
properly.
14Vdc
+ -
NO YES
End of line
EOL = yes
[PC line]
Comlink-1 Card
1
END OF LINE
2 3
EOL = yes
[PC line]
**
WIRING DIAGRAM
CC24-7 ELITE
#891-00003 Rev.10
  • Page 1 1
  • Page 2 2
  • Page 3 3