Lincoln LFC 3000 is an essential tool that will improve the efficiency of your service workshop through precise management of fluids and security. You will have the ability to control access to hoses, precisely meter the usage of products such as oil and antifreeze, and accurately track and account for every transaction. After each completed transaction, a ticket will be printed containing relevant data such as the job number, product name, amount dispensed, mechanic's name, hose used, type of transaction, and the remaining inventory of the dispensed product.

Lincoln LFC 3000 is an essential tool that will improve the efficiency of your service workshop through precise management of fluids and security. You will have the ability to control access to hoses, precisely meter the usage of products such as oil and antifreeze, and accurately track and account for every transaction. After each completed transaction, a ticket will be printed containing relevant data such as the job number, product name, amount dispensed, mechanic's name, hose used, type of transaction, and the remaining inventory of the dispensed product.

Page
Section
- F60
- 2
Form 403082
June 2002
LFC 3000 Users Manual
Series A
Page Number - 2
LFC 3000 Users Manual
Series A
Form 403082
IMPORTANT SAFETY INSTRUCTIONS.
1. Before installing or using this product, please read the
instruction manual thoroughly.
2. Unpacking: Please check that the product is complete
and free from any damage
3. Only qualified individual should install and/or repair this
product.
4. Unplug the LFC3000 from the electrical outlet before you
clean it.
Use a damp cloth for cleaning and do not use liquid or
aerosol cleaners.
5. Do not place the LFC3000 on an unstable surface that
may allow the unit to fall.
6. Never place the LFC3000 near or over a radiator or heat
register.
7. Use the type of power source indicated on the label (AC
power). If you are not sure of the type of power available,
consult your supplier or local electric company.
8. The LFC3000 must be equipped with a plug having a
third (grounding) pin, which fits only into a grounding-
type outlet. This is a safety feature. LFC3000 should not
be used without a properly grounded outlet. Failure to
properly ground the LFC3000 may cause damage to the
unit or the data stored.
9. Do not put the LFC3000 where the cord will be walked
on.
10. An extension cord is not recommended for use with the
LFC3000.
If you use an extension cord, make sure that the total of
the ampere ratings on the products plugged into the
extension cord does not exceed the extension cords
ampere rating. Also make sure that the total of all
products plugged into the wall outlet does not exceed
15 amperes.
11. Unplug the LFC3000 from the wall outlet and have it
repaired by a qualified service person under the
following conditions:
A. When the power cord or plug is damaged or frayed.
B. If liquid has been spilled into it.
C. If it has been exposed to rain or water.
D. If it does not operate normally when the operating
instructions are followed. Adjust only those controls that
are covered by the operating instructions since improper
adjustment of other controls may result in damage and
lose of data.
E. If it has been dropped or damaged.
If it exhibits a distinct change in performance, indicating
a need for service.
Table of Contents
Safety Instructions..........................................................................2
Description......................................................................................3
Memory Protected..........................................................................3
Technical Data................................................................................4
User Menu.......................................................................................4
Supervisor Menu............................................................................4
Customer Menu..............................................................................6
System Menu..................................................................................8
Transaction Codes......................................................................11
Flow Chart for Screens................................................................12
Failure to adhere to these safety instructions may result
in serious bodily injury or death.
Page Number - 3
Form 403082
LFC 3000 Users Manual
Series A
DESCRIPTION
The LFC 3000 is a modular fluid management/security
system for service workshops. It provides the shop supervi-
sor with a host of services required for precise manage-
ment of an inventory of products such as oil and antifreeze.
The LFC 3000 maintains the inventory by controlling access
to hoses, precise metering of the products, and accurate
accounting.
A transaction ticket is printed upon completion of all transac-
tions and an inventory report showing all product levels is
available to the supervisor.
The LFC 3000 will keep up to 1900 transactions in its
protected memory. A transaction historic report keeps track
of all the transactions, classified by users, products or
hoses.
The modularity of the LFC 3000 makes it adaptable to your
existing workshop and upgradable in the future. It is
comprised of 1 to 8 I/O modules, 1 to 64 data entry keypads,
1 to 16 optional remote displays and 1 optional PC
interface.
The I/O module is the operating intelligence. Each I/O
module supports up to 8 counter inputs and controls up to 8
solenoid drivers - this means that the LFC 3000 can operate
up to 64 hose reels all simultaneously. One I/O module can
communicate with 1 to 8 data entry keypads. The I/O module
also supports one additional output for activating or disacti-
vating the main air supply.
The data entry keypad provides access to the system for oil
monitoring and dispensing procedures. Configuration of
the system is also done from the keypad (for installations
without PC). The keypads are all alphanumerical and
equipped with a serial port to provide connection to a serial
printer.
The remote display has large 56 mm digits to visualize the
quantity currently dispensed.
The PC interface is available as an option and offers
extended remote transaction memory, computer interfacing
and the possibility to control up to 24 I/O units - which
means 192 outlets. A complete management software
package is supplied with the PC interface. The software is
Windows compatible and does not require a dedicated PC.
To initiate a transaction, a personal identification number
(PIN) must be entered via the data entry keypad. Any keypad
can communicate with any I/O module. A job number, a hose
number and the preset amount must be entered. The
technician then begins dispensing the product. The amount
of product dispensed is displayed on the remote display.
When a transaction ends, a transaction ticket is printed on
the printer, and the appropriate inventory is reduced by the
amount dispensed. Transactions will also end whenever
dispensing stops for a certain time period.
The transaction ticket contains all data relevant to the
transaction including the job number, the product name, the
amount dispensed, the mechanics name, the hose used,
the type of transaction, the time and date and the remaining
inventory of the dispensed product.
The LFC 3000 controls up to 64 hoses and can maintain an
inventory of up to 8 tanks. The system can be configured for
use with pulse meters that are single channel or quadrature
(w&m approved).
Access to functions such as configuration and report
printing is restricted to different security levels; a supervisor
code must be entered before these functions can be used.
The supervisor can select the language that will be used
throughout the system.
MEMORY PROTECTED
The LFC 3000 is provided with a battery backed RAM to
store up to 1900 completed transactions to guard against
data loss in the event of a power failure.
Transaction ticket: Audit trail of all completed jobs
Stock level: Stock level of each product tank
with minimum stock level
Product delivery: Details of all deliveries entered
into the system, date and quantity -
and stock corrections.
Transaction reports: Product report - usage and totals
Hose reports - usage and totals
User report - usage and totals
All transactions - usage and totals
(data retrieved from system
memory)
Alarm ticket: If a high level warning switch is
fitted to the waste oil collection
tank, a ticket is printed
immediately as a warning
Tank low level warning: When the minimum tank level is
reached, a warning ticket is
printed
Job report: Report review by job number for
different grades against the same
job number and from one date to
another (PC level only).
License plate report: Historic report by license plate
number (PC level only)
Configuration: Keeps track of the system
configuration for reconfiguration
and after sales service.
Note: All the above reports are available to be printed
except where shown as PC level only. When a PC
is incorporated, all reports can be viewed on
screen before printing.
Page Number - 4
LFC 3000 Users Manual
Series A
Form 403082
Enter Hose
_ 0
Enter the hoses number, which corresponds to your request.
Press ENTER
Product
(Products name)
The system confirms the products name dispensed on the
selected hose. Press ENTER
Enter quantity
6.7
(Optional Dispense mode: Pre-select or Free dispense)
Enter the desired quantity. Press ENTER
Dispense product
SUPERVISOR MENU
The Supervisor menu is accessible through all the keypads
by entering the Supervisor PIN Number. Every 45 seconds
without use of the keypad, the display shows you the date &
time and resets the network. The factory PIN number for the
supervisor menu is 9999.
Enter Pin No.
9999
Good Morning
Supervisor
Supervisor Menu
Start / Stop
The selection Start/Stop allows the supervisor to restart the
system. ENTER
System State
Active
ENTER
Supervisor Menu
Transaction Report
Upon request, the supervisor can print the transactions
reports. These reports will give him precise history of fluids
dispensed and totals. All the reports are printed on the
report printer as configured in the system configuration
menu.
TECHNICAL DATA
Network specifications
The LFC 3000 operates with a CAN Bus network that uses two
wires and a shield.
System specifications
Keypads on a system 64 max.
I/O modules on a system 8 max.
Solenoid valves on a system 64 max.
Meters with single channel pulse transmitters 64 max.
Fluids on a system 8 max.
Number of operators 99 max.
Transaction log 1900 max.
Simultaneous dispenses 64 max.
Printers per system 64 max.
Power supply
The LFC 3000 operates on a 24 VDC voltage.
A power supply unit is included in the system - Voltage Input
90-120 Volts AC, 50/60 Hz single phase.
Default PIN Numbers
The factory PIN numbers are as follows:
Supervisor Menu......................................................................9999
Customer Menu........................................................................1111
System Menu...........................................................................2222
USER MENU
The user menu is accessible through all the keypads. Only
the personal PIN code gives
access to this menu.
Enter Pin No.
****
Good Morning
(Users name)
Enter Job No.
.
Enter the number of the job, Press ENTER
Enter Reg. No.
.
(Optional)
Enter the vehicle plate number (Alphanumerical), Press
ENTER
Enter Reg. No.
.
(Optional)
Enter the vehicle mileage. Press ENTER
Page Number - 5
Form 403082
LFC 3000 Users Manual
Series A
sor PIN Number has been forgotten, it will be necessary to
reset the system. See Instruction Manual under Trouble-
shooting, Lost Supervisor PIN.
ENTER
Supervisor pin
9999
ENTER
Supervisor Menu
Set super PIN
ENTER
Confirm PIN
****
ENTER
Confirm PIN
Confirmed
ENTER
Supervisor Menu
Clear transactions
ENTER
We advise you to clear regularly the transactions when you
use the system without PC: the transactions number is limit-
ed to 1900. Moreover, when you print the report, you will have
the printing of all the transactions since the last Clear trans-
actions. Answering Yes will automatically clear all transac-
tions in the memory of the system. To avoid clearing transac-
tions by mistake, the system is proposing a No answer.
Using the down arrow will bring the Yes answer on the
screen.
ENTER
Clear Transactions
No
Down
ENTER
Are you sure?
No
Down
ENTER
Suggestion: print your transaction reports before clearing
transactions.
Transaction reports are available:
By user Report by user (Enter the users number)
By hose Report by hose (Enter the hoses number)
By product Report by product (Enter the products
number)
All trans-
actions All Reports
Exit
Supervisor Menu
Delivery Rep.
LFC 3000 prints a hard copy of all your stock modifications.
We recommend you to print this report after each product
delivery entered in the system.
Supervisor Menu
Stock Level Rep.
Prints the stock and the minimum levels for all the config-
ured tanks.
Supervisor Menu
Product Delivery
Enter here your new oil deliveries. The new stock will be
calculated automatically. Suggestion: Print a delivery report
after entering deliveries.
Use Up / Down key to select the desired tank. ENTER
Supervisor Menu
New Stock Level
If you want to modify the stock level:
ENTER
New Stock Level
Tank 1 = 200
New Stock Level
300 lts
Supervisor Menu
Set Date / Time
ENTER
Date 17-05-02
Time 15:09
In a multi I/O system, this parameter must be the same on
each I/O. Every 45 seconds without use of the keypad, the
display shows you the date & time and reset the network.
Supervisor Menu
Set super PIN
This prompt is used to change the Supervisor PIN Number.
Only numerical PIN is accepted by the system. If the supervi-
Page Number - 6
LFC 3000 Users Manual
Series A
Form 403082
CUSTOMER MENU
The Customer Configure Menu is accessible though all the
keypads. At the initialization of the system or when modifi-
cations are done on this menu, the data is automatically
updated at the other keypads through the network. It is not
necessary to configure all the keypads separately.
Customer Menu
Products
All the fluids controlled by the system can be identified in
alphanumerical characters. In certain installations, the
same product can be pumped from different tanks (maxi-
mum 8 tanks). The LFC 3000 allows you to manage these
tanks separately to control their respective stock level.
Assign the tank from which the product will be pumped.
Enter
Tank Number 1
Enter the tank number
ENTER
Product 1
Motor Oil
Use Up / Down key to select the product number
ENTER
Enter the products identification by using the alphanumeric
keypad
ENTER
The system goes back to the prompt Products
Customer Menu
Hose
All your dispensing points (hoses) must be linked to the tank
it is dispensing from.
ENTER
Enter Hose
01
Enter the hose number
ENTER
Enter Tank
01
Enter the tank number
ENTER
The system will confirm the name of the product configured
for verification;
Select Product
Motor Oil
ENTER
Enter hose 00 to exit
Supervisor Menu
Add New User
Up to 99 users can be stored in the system. Any 4 digit PIN
numbers can be assigned to an operator. It is recommend-
ed that the supervisor keep a list of the PIN numbers in
case he needs to remove one of them. Two users cannot
have the same PIN Number.
ENTER
New User Pin
****
ENTER
New User Name
(User name)
ENTER
New User Name
User added
Supervisor Menu
Remove User
ENTER
Enter Ex-PIN
****
ENTER
Enter Ex-PIN
User deleted
The user will be deleted from the system.
Supervisor Menu
Customer Config.
ENTER
Customer cfg. PIN
1111
Access to the customer security level. Factory PIN number for
customer menu is 1111.
Supervisor Menu
Exit
ENTER
Return to User Screen
Page Number - 7
Form 403082
LFC 3000 Users Manual
Series A
Dispense Mode
Pre-Select - Free Dispense
Customer Menu
Odometer & Reg.
With the LFC 3000 you can store the odometer reading and
the license plate number of the vehicles maintained in the
garage. This information will appear on the transaction
ticket;
ENTER
Odometer & Reg.
Yes
Use Up / Down keys to select
The keypad will always ask the operator to store the
odometer and registration plate of the vehicle
corresponding to the job number.
Odometer & Reg.
No
The function will not be activated.
Customer Menu
Initial Timeout
The initial time-out is the time between the validation of the
transaction datas on the keypad and the opening of the
solenoid valve corresponding to the selected hose. Enter
the maximum number of seconds necessary before starting
the operation.
In a multi I/O system without PC, this parameter must
programmed and be the same and on each I/O.
ENTER
Initial Timeout
06
Customer Menu
Inactive Timeout
The inactive timeout is the period between the last pulse
received by the system and the closing of the solenoid. The
LFC 3000 will close the transaction if the time between 2
pulses reaches the inactive-time configured in the system.
It is visualized that the operator has started to fill the vehicle
with oil and that he has stopped the dispense before the
pre-set quantity has been reached or because he is work-
ing in the free dispense mode. When choosing this dura-
tion, bear in mind that this should be long enough for your
worker to verify the oil level on the dip stick. Enter the
maximum number of seconds needed.
Customer Menu
Warn Level
A minimum stock level must be set for each tank. All fluids
dispenses will automatically be deducted from the respective
tank stock. When the stock level in the tank reaches the warn-
ing level, a warning reordering message will automatically be
printed on the report printer.
ENTER
Use Up / Down arrow key to select the tank
Warn Level
Tank 1 = _ _ _ _
ENTER
Warn Level
_ _ _ _ 0
Enter the minimum stock level
ENTER
Warn Level
400
Customer Menu
Stop Level
In addition to the minimum level, the LCF 3000 offers the
ability to set up stop levels for each tank, preventing
dispenses of the selected product when the level in the tank
is under the stop level limit. This will prevent air to enter in
the oil line and prevent any risk of impurities entering the
line as well.
ENTER
Stop Level
Tank 1 = _ _ _ _ 0
Choose the tank you want to configure.
ENTER
New Stop Level
_ _ _ _ 0
Customer Menu
Dispense Mode
The LFC 3000 offers the possibility for the operator to
dispense oil in Pre-Select or in free dispense mode. In Pre-
select mode, the system will not authorizes any dispense
without a pre-selected quantity of fluid. In free dispense, the
system will authorize dispenses without pre-selection of any
quantity.
The system will close the transaction when the inactive
time-out has been reached.
ENTER
Use Up / Down key to select the mode.
Page Number - 8
LFC 3000 Users Manual
Series A
Form 403082
Inactive Timeout
120
In a multi I/O system without PC, this parameter must
programmed and must be the same on each I/O.
Customer Menu
Set Language
ENTER
Use Up / Down key to select the language.
LFC 3000 is a multi language system. The default
language is British English.
To change to American English, you must enter US0011.
This will also change the unit of measurement from liters to
quarts.
Customer Menu
Set Customer PIN
This prompt is used to change the Customer PIN number.
Only numerical PIN is accepted by the system.
If the Customer PIN has been forgotten, it will be necessary
to reset the system and re-configure. See Instruction
Manual, under Troubleshooting, Lost Supervisor Pin.
ENTER
Customer Cfg PIN
****
ENTER
Confirm PIN
****
Confirm PIN
Confirmed
System Menu
Diagnostics
As a support for the installer and after sales services, LFC
3000 provides a diagnostic report:
- the configuration for the installation parameters
- the names of the products
- the number of the users, their names and their
PIN codes
- the hoses, tanks, products names, displays and
corrections factors
We advise you to print this diagnostic after each installation.
Customer Menu
Configure System
ENTER
System Cfg PIN
2222
Access to the System Configuration installer level. The
factory PIN number is 2222 for the System Menu.
Customer Menu
Exit
ENTER
Return to the supervisor menu prompt. To return to the User
Screen, press ENTER again.
SYSTEM MENU
The System Configuration Menu is accessible through all
the keypads. The modified data is automatically updated at
the other keypads through the network. It is not necessary to
configure all the keypads separately. Only ticket (A&B)
printers must be configured on each keypad.
System Menu
Test Mode
ENTER
Use Up / Down key to select the test.
-Test A: test the opening/closing for each solenoid.
The test A from a keypad is only valid for the
solenoid valves connected on the I/O unit
communicating with this keypad.
-Test B: factory use only
-Test C: test to confirm the address of each large character
remote display
display address 0: random figures
display address 1: figures 000.1
display address 2: figures 000.2
Etc
-FLT FLT FLT FLT or OK OK OK OK: this test is only valid for
quadrature pulsers.
You have the possibility to test a maximum of 4 quadrature
pulsers connected on the I/O Unit.
The position of the message indicates where the position of
the pulser is.
An OK message indicates that the quadrature pulser is not
connected.
If you connect single pulsers, a FLT message will appear.
-none
System Menu
Display Allocation
The LFC 3000 offers the use of remote displays for an easy
visualization of the oil dispensed by the worker. This screen
allows you to program in the system on which display the
worker wants to visualize his dispenses. One display can
be used for multi hose reels.
Page Number - 9
Form 403082
LFC 3000 Users Manual
Series A
Report Address
I/O Control
ENTER: The report printer is connected to an I/O unit
(ID=0). Use Up / Down key to select
Report Address
Keypad x
ENTER: The report printer is connected on the keypad
number X.
Use Up / Down key to select until you have the correct
address.
ENTER
Report Address
None
ENTER: There is no report printer on the system.
Use Up/Down keys to select.
ENTER
System Menu
Set Ticket A Adr.
To fulfill all the needs of the garage supervisors, LFC 3000
offers the flexibility to print the transaction tickets on different
printers. All the printers must be connected through the
serial port and be Epson emulated. This instruction must
be done on EACH keypad.
The Factory default setting is Ticket A address on Keypad 0.
ENTER
Ticket A Address
I/O Control Unit
ENTER: The ticket A printer is connected on the I/O unit
(ID=0)
Use Up / Down keys to select.
Ticket A Address
Keypad X
ENTER: The ticket A printer is connected on the keypad
number X.
Use Up/Down key to select the address.
ENTER
Ticket A Address
None
ENTER: There is no ticket A printer on the system.
Use Up/Down keys to select.
ENTER
Every display is delivered with dip switches on the PC
board. See Instruction Manual, Wiring the display.
ENTER
Select Hose
01
ENTER
Select Display
00
ENTER
Hose Number 1 will be visualized on display Number 00.
System Menu
Set Encoder Type
LFC 3000 allows the use of single channel and dual
channels pulse transmitters.
By default, all the systems are programmed to be use with
single channel pulse transmitters.
ENTER
Set Encoder type
Quadrature
Quadrature corresponds to dual channel pulse transmitter.
Use Up / Down keys to select.
Set Encoder type
Single Channel
Single channel pulse transmitter.
In a multi I/O system without PC, this parameter must be
programmed and be the same on each I/O.
ENTER
System Menu
System Type
System Type
Non-Master
Use Up / Down keys to select.
Non-Master is used without PC.
Master is used with PC.
ENTER
System Menu
Set Report Adr.
A Main printer is necessary to print the entire statistic, stock
level reports and diagnostic.
This printer must be 80 columns; Epson emulated with a
serial port.
The factory default setting is report address on Keypad 0.
ENTER
Page Number - 10
LFC 3000 Users Manual
Series A
Form 403082
System Menu
Set Ticket B Adr.
To fulfill all the needs of the garage supervisor, LFC 3000
offers also the flexibility to print a copy of the transaction
tickets. All the printers must be connected through the serial
port and be Epson emulated. This printer can be the main
printer. This instruction must be done on EACH keypad. The
factory default setting is ticket B address on keypad 0.
Ticket B Address
I/O Control Unit
ENTER: The ticket B printer is connected on the I/O unit
(ID=0)
Use Up / down keys to select.
Ticket B Address
None
ENTER: There is no ticket B printer on the system.
Use Up / Down keys to select
Ticket B Address
Keypad x
ENTER: The ticket B printer is connected on the keypad
Number x.
Use Up / Down keys to select the address
ENTER
System Menu
Set System PIN
The system PIN code can be modified. Only numerical PIN
is accepted by the system. If the system PIN Number has
been forgotten, it will be necessary to reset the system and
re-configure. See Instruction Manual, under Troubleshoot-
ing, Lost Supervisor PIN.
ENTER
System Cfg PIN
****
LFC 3000 operates all the hose reels simultaneously or one
hose reel at a time. When the system is configured in
simultaneous mode, you will be able to dispense on all the
different hoses at the same time.
The factory default setting is simultaneous.
System Menu
Set Simultaneous Mode
ENTER
Set Simultaneous Mode
Non-Simultaneous
Use Up / down keys to select.
Set Simultaneous Mode
Simultaneous
In a multi I/O system without PC, this parameter must
programmed and must be the same on each I/O
ENTER
System Menu
Pulses per Liter
LFC 3000 is designed to register pulses from 1 to 255 per
liter. Refer to the type of pulse transmitter. To change to
pulses per quart see user menu, Set Language, change
to American English.
Pulse per Liter
100
In a multi I/O system without PC, this parameter must
programmed and be the same and on each I/O.
ENTER
System Menu
Max. Dispense
ENTER
Select Hose
0
Max. Dispense
_ 100
ENTER the maximum quantity that will be allowed to be
dispensing on the selected hose.
Then press ENTER and do the same for the other hoses.
System Menu
Decimal Place
Decimal Place
1
You can choose the place of the decimal. You only have 1 or
2 (use the Up / down arrow key).
( You also have to change physically the jumper located in
the display). ENTER
Page Number - 11
Form 403082
LFC 3000 Users Manual
Series A
System Menu
Hose Calibration
This prompt is offering the possibility to correct the delay of
the solenoid valve shut-off.
When an operator presets a quantity of fluid to be dis-
pensed, the system will automatically close the solenoid
valve when the preset quantity has been reached. The LFC
3000 counts the pulses coming from the pulse transmitter.
Assuming that the pulse transmitter type is 100 pulses per
liter, the calibration procedure will be as follows;
Preset quantity: 4 liters = 400 pulses
Quantity dispensed: 4.1 lit. = 410 pulses
Difference: 0.1 lit. = 10 pulses
10 will be the calibration factor to enter in the system.
ENTER
Select Hose
01
ENTER
Pulse count
10
ENTER
System Menu
Change I/O ID
By default all the I/O units have the same address (ID)
Number 0 corresponding to solenoid drivers (hose reels) 1
to 8. For the installation with multi I/O units (more than 8
hosereels), each I/O must have its own address to be
identified by the network.
Power up each I/O successively and change their address.
For example ID Number 1 for solenoid drivers (hose reels)
9 to 16.
ENTER
Changer ID I/O
From 0 to 1
ENTER
The network communicates now with this I/O unit 1 for
hoses 9 to 16.
System Menu
Exit
ENTER
Return to Customer Configure Menu at the exit prompt. To
return to the User screen, press twice ENTER.
TRANSACTION CODES
Explanations for the transaction end codes
printed on each transaction ticket:
0 Means that the transaction has been stopped after
the inactive Timeout:
- its normal in free dispense mode
- The preset quantity has not been totally dispensed
1 In preselect mode, the preset quantity has been
totally dispensed: Completed
2 Input Error in the pulses sequence: for quadrature
pulsers only
3 Count Error: missing pulse in quadrature pulsers
only
4 It means that the power has been shut down during
the transaction: Power down
5 The transaction has been stopped by the emergency
procedure (): System inactive
6 IOP Error: Microprocessor Error
7 Unauthorized transaction: for approved systems only,
quantity dispensed between 0.5Lt and 100Lt.
Page Number - 12
LFC 3000 Users Manual
Series A
Form 403082
FLOW CHART
Enter PIN Number
_ _ _ _
Good Morning
User’s Name
Enter Job Number
_ _ _ _
Good Morning
Supervisor
9999 Enter
Supervisor Menu
Start/Stop
(Enter Reg Number)
_ _ _ _
(Enter Od Number)
_ _ _ _
Enter Hose
_ _ _ 0
Product
Product’s Name
(Enter Qty)
6.7
Dispense Oil
Supervisor Menu
Transact. Rep.
Supervisor Menu
Delivery Rep.
Supervisor Menu
Stock Lev. Rep.
Supervisor Menu
New Stock Level
Supervisor Menu
Set date/time
Supervisor Menu
Set Super PIN
Supervisor Menu
Clear Transacts.
Supervisor Menu
Add new user
Supervisor Menu
Remove user
Supervisor Menu
Cust. Config.
Supervisor Menu
Exit
Customer Menu
_ _ _ _
Customer Menu
Products
Customer Menu
Hose
Customer Menu
Warn. Level
Customer Menu
Stop Level
Cust. Menu
Dispense Mode
Customer Menu
Odom. & Reg.
Customer Menu
Inact. Timeout
Customer Menu
Exit
Customer Menu
Config. Syst.
Customer Menu
Diagnostic
Customer Menu
Init. Timeout
Customer Menu
Set Cust. PIN
Customer Menu
Set Language
Enter
Enter
System Menu
_ _ _ _
System Menu
Test Mode
PIN user - Enter
1111 - Enter
2222 - Ente
r
System Menu
Display Alloc.
System Menu
Exit
System Menu
Change I/O ID
System Menu
Hose Calibration
System Menu
Decimal Place
System Menu
Max Dispense
System Menu
Pulses Per Quart
Syststem Menu
Set Simul. Mode
System Menu
Set Syst. PIN
System Menu
Set Ticket B Address
System Menu
Set Ticket A. Address
System Menu
Set Rep. Addr.
System Menu
System Type
System Menu
Set Encoder Type
Enter
Supervisor Menu
Prod. Delivery
Customer Menu
Stock Mode
Americas:
One Lincoln Way
St. Louis, MO 63120-1578
USA
Phone +1.314.679.4200
Fax +1.800.424.5359
Europe/Africa:
Heinrich-Hertz-Str 2-8
D-69183 Walldorf
Germany
Phone +49.6227.33.0
Fax +49.6227.33.259
Asia/Pacific:
25 Intl Business Park
#01-65 German Centre
Singapore 609916
Phone +65.562.7960
Fax +65.562.9967
© Copyright 2002
Printed in USA
Web site:
www.lincolnindustrial.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Lincoln LFC 3000 User manual

Type
User manual

Lincoln LFC 3000 is an essential tool that will improve the efficiency of your service workshop through precise management of fluids and security. You will have the ability to control access to hoses, precisely meter the usage of products such as oil and antifreeze, and accurately track and account for every transaction. After each completed transaction, a ticket will be printed containing relevant data such as the job number, product name, amount dispensed, mechanic's name, hose used, type of transaction, and the remaining inventory of the dispensed product.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI