Acnodes PCM8210 Owner's manual

Type
Owner's manual
Test Report
Date : Oct 27, 2016
Page 1 of 17
S
ample Description:
One (1) unit of submitted sample said to be :
Item No.
Quantity
: PCM8210
: 1 unit
Date Sample Received : Oct 21, 2016
Date Test Started : Oct 21, 2016
Tests Conducted:
As requested by the applicant, for details please refer to attached pages.
Test Sample:
Sample No. : P161000212
Standard:
Vibration Test
Mechanical Shock Test
-
-
With reference to MIL-STD-810G Method 514.6
With reference to MIL-STD-810G Method 516.6
Test result:
See test conducted
Test Report
Date : Oct 27, 2016
Test Conducted
Page 2 of 17
1. Vibration Test
Test Equipment:
Equipment : Vibration Shaker
Manufacturer : Shinken
Model Number : G-0220N
Due Date of Calibration : Sep. 29, 2017
Laboratory Ambiance Condition:
Temperature : 15 ~ 35
Humidity : 25 ~ 75 %RH
Reference Document:
The test was performed with reference to MIL-STD-810G Method 514.6
Peripheral Setup Diagram:
-Sample size: 1 unit
-Sample photo before the test:
-
Setup photo:
Z axis Y axis X axis
Test Report
Date : Oct 27, 2016
Test Conducted
Page 3 of 17
1. Vibration Test
Test Condition:
Test 1
-Pulse Shape: Random wave
-Non operation test
-Frequency Range: 5 Hz to 500 Hz
-Acceleration: 2.24 Grms
-Duration: 60 minute/axis
-Direction: Z axis
-Spectrum:
Frequency(Hz) PSD(G
2
/Hz)
5 0.1759
8 0.5120
11 0.0660
12 0.0585
13 0.348
15 0.1441
16 0.1237
20 0.0241
23 0.0536
26 0.0124
27 0.0118
30 0.0331
34 0.0086
39 0.0347
43 0.0073
45 0.0141
49 0.0084
52 0.0089
57 0.0045
67 0.0160
80 0.0037
90 0.0077
93 0.0053
98 0.0065
99 0.0063
111 0.0046
123 0.0069
128 0.0055
164 0.0031
172 0.0035
215 0.0133
264 0.0056
276 0.0096
292 0.0032
348 0.0044
417 0.0031
500 0.0008
Test Report
Date : Oct 27, 2016
Test Conducted
Page 4 of 17
1. Vibration Test
Test 2
-Pulse Shape: Random wave
-Non operation test
-Frequency Range: 5 Hz to 500 Hz
-Acceleration: 1.48 Grms
-Duration: 60 minute/axis
-Direction: Y axis
-Spectrum:
Frequency(Hz) PSD(G
2
/Hz)
5 0.0998
7 0.0799
9 0.1115
10 0.0577
14 0.0294
15 0.0651
16 0.0646
17 0.0436
18 0.0393
19 0.0622
24 0.0100
37 0.0045
38 0.0065
44 0.0033
55 0.0024
57 0.0042
59 0.0019
76 0.0012
79 0.0021
83 0.0010
114 0.0006
135 0.0017
142 0.0010
158 0.0018
185 0.0010
191 0.0007
206 0.0008
273 0.0035
300 0.0016
364 0.0074
374 0.0022
395 0.0051
500 0.0012
Test Report
Date : Oct 27, 2016
Test Conducted
Page 5 of 17
1. Vibration Test
Test 3
-Pulse Shape: Random wave
-Non operation test
-Frequency Range: 5 Hz to 500 Hz
-Acceleration: 1.90 Grms
-Duration: 60 minute/axis
-Direction: X axis
-Spectrum:
Frequency(Hz) PSD(G
2
/Hz)
5 0.0441
7 0.0390
8 0.0576
9 0.0430
10 0.0293
13 0.0221
15 0.0558
16 0.0585
18 0.0160
20 0.0099
23 0.0452
25 0.0110
35 0.0036
37 0.0098
40 0.0040
41 0.0044
45 0.0023
47 0.0047
50 0.0016
45 0.0017
64 0.0010
69 0.0030
77 0.0007
85 0.0015
90 0.0012
97 0.0015
104 0.0036
114 0.0040
122 0.0015
132 0.0013
206 0.0033
247 0.0226
257 0.0041
264 0.0054
276 0.0040
303 0.0073
332 0.0092
353 0.0172
382 0.0071
428 0.0157
500 0.0016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 6 of 17
1. Vibration Test
Test Procedure:
-Check the sample’s appearance before the test.
-Install the sample on testing table and set up testing condition.
-After testing, take off sample from table and put it in the storage area.
-Observe the sample and record for any visible change after testing.
Summary:
-No visible damage was found after the test.
-Functional electrical test is performed by the applicant per applicant’s request.
-Sample photo after the test:
Test Report
Date : Oct 27, 2016
Test Conducted
Page 7 of 17
1. Vibration Test
-Test profile:
Z axis
profile(f)
high-abort(f)
low-abort(f)
high-alarm(f)
low-alarm(f)
control(f)
500.005.00 10.00 100.00
4.4668
6.31E-05
0.0001
0.0010
0.0100
0.1000
1.0000
Frequency (Hz)
(gn)?Hz
Level: 100 %
Full Level Elapsed Time: 01:00:00
Demand RMS: 2.245294 gn
Data saved at 04:15:03 PM, Friday, October 21, 2016
Report created at 04:15:06 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 8 of 17
1. Vibration Test
-Test profile:
Y axis
profile(f)
high-abort(f)
low-abort(f)
high-alarm(f)
low-alarm(f)
control(f)
500.005.00 10.00 100.00
0.9528
3.98E-05
0.0001
0.0010
0.0100
0.1000
Frequency (Hz)
(gn)?Hz
Level: 100 %
Full Level Elapsed Time: 01:00:00
Demand RMS: 1.471470 gn
Data saved at 03:05:11 PM, Friday, October 21, 2016
Report created at 03:05:17 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 9 of 17
1. Vibration Test
-Test profile:
X axis
profile(f)
high-abort(f)
low-abort(f)
high-alarm(f)
low-alarm(f)
control(f)
500.005.00 10.00 100.00
0.4786
6.31E-05
0.0001
0.0010
0.0100
0.1000
Frequency (Hz)
(gn)?Hz
Level: 100 %
Full Level Elapsed Time: 01:00:00
Demand RMS: 1.898276 gn
Data saved at 05:27:40 PM, Friday, October 21, 2016
Report created at 05:27:43 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 10 of 17
2. Mechanical Shock Test
Test Equipment:
Equipment : Vibration Shaker
Manufacturer : Shinken
Model Number : G-0220N
Due Date of Calibration : Sep. 29, 2017
Laboratory Ambiance Condition:
Temperature : 15 ~ 35
Humidity : 25 ~ 75 %RH
Reference Document:
The test was performed with reference to MIL-STD-810G Method 516.6
Peripheral Setup Diagram:
-Sample size: 1 unit
-Sample photo before the test:
-
Setup photo:
±Z axis-1 ±X axis-1 ±Y axis-1
Test Report
Date : Oct 27, 2016
Test Conducted
Page 11 of 17
2. Mechanical Shock Test
±Z axis-2 ±X axis-2 ±Y axis-2
Test Condition:
-Operating: Input electrcial power to operate during the test
-Pulse shape: Sawtooth wave
-Acceleration: 40 G
-Pulse duration: 11 ms
-Test face:
Test Face Shock Times
+Z axis 3
-Z axis 3
+X axis 3
-X axis 3
+Y axis 3
-Y axis 3
Test Procedure:
-Check the sample’s appearance before the test.
-Install the sample on the testing table and set up testing condition.
-After testing, take off sample from table and put it in the storage area.
-Observe the sample and record for any visible change after testing.
Summary:
-No visible damage was found after the test.
-Functional electrical check is conducted by the applicant per applicant’s request.
-Sample photo after the test:
Test Report
Date : Oct 27, 2016
Test Conducted
Page 12 of 17
2. Mechanical Shock Test
-Test profile:
+Z axis
profile(t)
high-abort(t)
low-abort(t)
control(t)
22-11 -9 -6 -3 0 3 6 9 12 15 18 21
54.0000
-27.5000
-25.0000
-20.0000
-15.0000
-10.0000
-5.0000
0
5.0000
10.0000
15.0000
20.0000
25.0000
30.0000
35.0000
40.0000
45.0000
50.0000
Time (Milliseconds)
gn
Level: 100 %
Full Level Elapsed Pulses: 3
Pulse Type: Forward Sawtooth
Amplitude: 40.000000 gn
Data saved at 05:51:00 PM, Friday, October 21, 2016
Report created at 05:51:03 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 13 of 17
2. Mechanical Shock Test
-Test profile:
-Z axis
profile(t)
high-abort(t)
low-abort(t)
control(t)
22-11 -9 -6 -3 0 3 6 9 12 15 18 21
27.5000
-54.0000
-50.0000
-45.0000
-40.0000
-35.0000
-30.0000
-25.0000
-20.0000
-15.0000
-10.0000
-5.0000
0
5.0000
10.0000
15.0000
20.0000
Time (Milliseconds)
gn
Level: 100 %
Full Level Elapsed Pulses: 3
Pulse Type: Forward Sawtooth
Amplitude: 40.000000 gn
Data saved at 05:53:06 PM, Friday, October 21, 2016
Report created at 05:53:09 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 14 of 17
2. Mechanical Shock Test
-Test profile:
+X axis
profile(t)
high-abort(t)
low-abort(t)
control(t)
22-11 -9 -6 -3 0 3 6 9 12 15 18 21
54.0000
-27.5000
-25.0000
-20.0000
-15.0000
-10.0000
-5.0000
0
5.0000
10.0000
15.0000
20.0000
25.0000
30.0000
35.0000
40.0000
45.0000
50.0000
Time (Milliseconds)
gn
Level: 100 %
Full Level Elapsed Pulses: 3
Pulse Type: Forward Sawtooth
Amplitude: 40.000000 gn
Data saved at 05:57:00 PM, Friday, October 21, 2016
Report created at 05:57:03 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 15 of 17
2. Mechanical Shock Test
-Test profile:
-X axis
profile(t)
high-abort(t)
low-abort(t)
control(t)
22-11 -9 -6 -3 0 3 6 9 12 15 18 21
27.5000
-54.0000
-50.0000
-45.0000
-40.0000
-35.0000
-30.0000
-25.0000
-20.0000
-15.0000
-10.0000
-5.0000
0
5.0000
10.0000
15.0000
20.0000
Time (Milliseconds)
gn
Level: 100 %
Full Level Elapsed Pulses: 3
Pulse Type: Forward Sawtooth
Amplitude: 40.000000 gn
Data saved at 05:58:32 PM, Friday, October 21, 2016
Report created at 05:58:35 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 16 of 17
2. Mechanical Shock Test
-Test profile:
+Y axis
profile(t)
high-abort(t)
low-abort(t)
control(t)
22-11 -9 -6 -3 0 3 6 9 12 15 18 21
54.0000
-27.5000
-25.0000
-20.0000
-15.0000
-10.0000
-5.0000
0
5.0000
10.0000
15.0000
20.0000
25.0000
30.0000
35.0000
40.0000
45.0000
50.0000
Time (Milliseconds)
gn
Level: 100 %
Full Level Elapsed Pulses: 3
Pulse Type: Forward Sawtooth
Amplitude: 40.000000 gn
Data saved at 06:09:13 PM, Friday, October 21, 2016
Report created at 06:09:16 PM, Friday, October 21, 2016
Test Report
Date : Oct 27, 2016
Test Conducted
Page 17 of 17
2. Mechanical Shock Test
-Test profile:
-Y axis
profile(t)
high-abort(t)
low-abort(t)
control(t)
22-11 -9 -6 -3 0 3 6 9 12 15 18 21
27.5000
-54.0000
-50.0000
-45.0000
-40.0000
-35.0000
-30.0000
-25.0000
-20.0000
-15.0000
-10.0000
-5.0000
0
5.0000
10.0000
15.0000
20.0000
Time (Milliseconds)
gn
Level: 100 %
Full Level Elapsed Pulses: 3
Pulse Type: Forward Sawtooth
Amplitude: 40.000000 gn
Data saved at 06:10:39 PM, Friday, October 21, 2016
Report created at 06:10:42 PM, Friday, October 21, 2016
End of Report
This report is made solely on the basis of your instructions and / or information and materials supplied by you and provide no warranty on the tested sample(s) be truly representative of the sample
source. The report is not intended to be a recommendation for any particular course of action, you are responsible for acting as you see fit on the basis of the report results. Acnodes under no
obligation to refer to or report upon any facts or circumstances which are outside the specific instructions received and accepts no responsibility to any parties whatsoever, following the issue of the
report, for any matters arising outside the agreed scope of the works. This report does not discharge or release you from your legal obligations and duties to any other person. You are the only one
authorized to permit copying or distribution of this report (and then only in its entirety). Any such third parties to whom this report may be circulated rely on the content of the report solely at their
own risk.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17