True Fitness Palladium Strength Rep Counter User manual

Category
Fitness, gymnastics & weight training
Type
User manual
OWNER’S
MANUAL
Model # SPLCTR
Note: SPL-0100 shown above, but this is the manual for all of the
Palladium Strength Rep Counters as the required assembly steps
are the same for each machine.
Revision 110520
Palladium Strength
Rep Counter
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 2 of 30
Strength
Rep Counter (Palladium Line)
IMPORTANT:
All products shown are prototype. Actual product delivered may vary.
Product specications, features & soware are subject to change without notice.
For the most up-to-date owners manual please visit www.truetness.com.
For documents in additional languages please visit www.truetness.com/resources/document-library/
IMPORTANTE:
Todos los productos mostrados son prototipos. La realidad el producto suministrado puede diferir.
Especicaciones de productos, características y soware están sujetas a cambios sin previo aviso.
Para la más actualizada de este manual del propietario, por favor visite www.truetness.com
Para los documentos en otros idiomas, por favor visite www.truetness.com/resources/document-library/
IMPORTANT: Tous les produits présentés sont prototype. Le produit réel livré peut varier. Spécications du
produit, caractéristiques et logiciels sont sujettes à modication sans préavis. Pour la plus à jour le manuel du
propriétaire s'il vous plaît visitez www.truetness.com. Pour documents dans des langues supplémentaires,
veuillez www.truetness.com/resources/document-library/ de visite
重要提示: 显示所有产品的原型。实际交付的产品可能有所不同产品规格功能和软件如有更改恕不另
行通知迄今为止对于大多数的使用说明书请访问www.true󼵠tness.com 对于其他语言的文档请访问
www.true󼵠tness.com/resources/document-library/
ھام:
جمیع المنتجات المعروضة ھي النموذج. قد تختلف المنتج الفعلي تسلیمھا.
مواصفات المنتج، والمیزات والبرامج قابلة للتغییر دون إشعار.
لمعظم ما یصل حتى الآن دلیل المالك یرجى زیارة www.truetness.com.
للمستندات في لغات إضافیة، یرجى زیارة www.truetness.com/resources/document-library/
WICHTIG: Alle hier gezeigten Produkte sind Prototypen. Das tatsächliche Produkt ausgeliefert wird, kann
variieren. Produkt-Spezikationen, Funktionen und Soware können sich ohne vorherige Ankündigung
ändern. In den meisten Fällen bis zu Bedienungsanleitung Bisher besuchen Sie bitte www.truetness.com. Für
Dokumente in weiteren Sprachen nden Sie unter www.truetness.com/resources/document-library/
BELANGRIJK: Alle getoonde producten zijn prototype. Daadwerkelijke product geleverd kan verschillen.
Product specicaties, eigenschappen & soware zijn onderhevig aan verandering zonder kennisgeving. Voor
de meest actuele handleiding van de eigenaar kunt u terecht www.truetness.com. Voor documenten in andere
talen kunt u terecht op www.truetness.com/resources/document-library/
ВАЖНО: Все товары указаны прототипа. Фактический продукт, поставляемый могут отличаться.
Технические характеристики, особенности и программного обеспечения могут быть изменены без
предварительного уведомления. Для получения самой последней на сегодняшний день руководство по
эксплуатации пожалуйста, посетите www.truetness.com
.Для документов на другие языки, пожалуйста, посетите www.truetness.com/resources/document-library/
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 3 of 30
Strength
Rep Counter (Palladium Line)
A MESSAGE TO OUR CUSTOMERS
Frank Trulaske began TRUE Fitness® over thirty-ve year ago with the simple philosophy of delivering superior
tness products, service, and support. Today, TRUE is the global leader in premium tness equipment for the
commercial and residential markets. Our goal is to be the leader in technology, innovation, performance, safety
and style. TRUE has received many awards for its product over the years and remains the benchmark for the
industry. Fitness facilities and consumers invest in TRUE products for their durable commercial platforms used
in all its products, both commercial and residential alike.
e proud manufacturing tradition of quality and the culture of innovation at TRUE have given rise to a full line
of extraordinary cardio and strength equipment. As a result, people all over the world are beneting from the
TRUE experience. Innovation across the full product line has made TRUE successful and is a trademark of the
TRUE heritage. TRUE’s patented Heart Rate Control technology is just one of the remarkable ways we deliver
simple and superior performance every user can enjoy, and most importantly, use to achieve personal health and
tness goals.
At the heart of our success is the relentless and systematic life testing of both our products and their components.
We have dedicated employees who understand our philosophy is to deliver the best products in the world.
Our goal is to deliver the worlds best premium equipment for our customers’ health and tness solutions.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 4 of 30
Strength
Rep Counter (Palladium Line)
Table of Contents
CHAPTER 1: SAFETY INSTRUCTIONS ..........................................................................................................................5
COMMERICAL MAINTENANCE SCHEDULE ......................................................................9
COMPLIANCES .............................................................................................................................9
CHAPTER 2: ASSEMBLY GUIDE ...................................................................................................................................10
REP COUNTER SENSOR MEASUREMENTS TABLE .......................................................... 10
REP COUNTER ASSEMBLY STEPS .........................................................................................11
CHAPTER 3: CARE & MAINTENANCE .......................................................................................................................22
CARE & MAINTENANCE .........................................................................................................22
DAILY INSPECTION & MAINTENANCE .............................................................................. 22
WEEKLY INSPECTION & MAINTENANCE .........................................................................22
OTHER SCHEDULED PREVENTIVE MAINTENANCE ....................................................23
CLEANING THE EQUIPMENT ...............................................................................................23
CABLE INSPECTION & MAINTENANCE ............................................................................. 24
CHAPTER 4: CUSTOMER SERVICE ..............................................................................................................................26
CONTACTING SERVICE ...........................................................................................................26
CONTACTING SALES ................................................................................................................26
REPORTING FREIGHT OR PARTS DAMAGE ......................................................................27
CHAPTER 5: WARRANTY INFORMATION ...............................................................................................................28
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 5 of 30
Strength
Rep Counter (Palladium Line)
CHAPTER 1: SAFETY INSTRUCTIONS
4
FF
AACCIILLIITTYY
AANNDD
UU
SSEERR
SS
AAFFEETTYY
PP
RREECCAAUUTTIIOONNSS
1. Review and understand all of the warning labels affixed to this machine and on the facility
safety sign.
2. Be certain that the machine operation is understood before it is used. Refer to the
instructional procedure label affixed to the machine.
3. Make sure all users are properly trained on how to use this equipment. If this machine is
being used in a commercial setting, end users may not have access to this owners manual. It is
the responsibility of the facility to instruct users as to the proper usage of the equipment as well
as making them aware of potential hazards. Maximum user weight is 300 lbs (136 kg) unless
otherwise stated in the manual.
4. Use each machine only for the intended exercise. Do not allow anyone to invent exercises not
included on the instructional procedure label or the intended use Label.
5. Do not modify the machine.
6. This equipment meets industry safety standards for stability when used for the intended
exercise. Do not allow straps, resistance bands or other means to be attached to the framework
of this machine to perform stretching or body weight exercises. This can result in machine
instability and lead to serious crushing injuries.
7. Keep children away from this equipment. Adults should closely supervise use by teenagers.
8. It is recommended that users receive a thorough medical exam before commencing an
exercise program. All medical issues should be reviewed to ensure that weight training will not
aggravate pre-existing medical conditions.
9. If the machine appears damaged or inoperable, contact a facility staff member to place an
OUT OF ORDER, DO NOT USE” sign on the machine until it is repaired. Only use TRUE
supplied replacement components to service this machine.
10.
I
nstruct users not to wear loose or dangling clothes or have headphone wires hanging
when using this equipment.
11. Do not attempt to free any jammed assemblies by yourself as this may cause injury.
12. On Plate Loaded and Free Weight machines:
12a. Use of spotter(s). Instruct users to seek the advice of the facility staff as to the
appropriate use of spotters when lifting. More than one spotter may be required
depending upon the amount of weight being lifted.
12b. Instruct users to load weight plates evenly and carefully to avoid tipping equipment
and crushing injuries.
12c. If the machine is equipped with safety stops or catches, inspect them and verify their
proper operation before use and make sure they are securely in place before using or
exiting the machine. Be certain members are instructed on how to operate and adjust
all safety mechanisms.
SAFETY
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 6 of 30
CHAPTER 1: SAFETY INSTRUCTIONS
Strength
Rep Counter (Palladium Line)
5
12d. This equipment is designed for standard olympic size weight plates with a 50mm bore
(1.9”).
12e. Do not exceed the maximum weight capacity of the machine. Maximum plate size is
45 lbs. (25 kg.).
13. On Selectorized and Cable equipped machines:
13a. Do not allow users to perform any exercise by holding the end of the cable and/or the
cable end fitting. Use only appropriate handles or attachments properly connected to
the cable end.
13b. Do not high-pin or double-pin the weight stack. Do not allow the machine to be used if
the top plate or weight stack is pinned in a raised position. Use an assistant and
carefully return the machine to the proper position with the cap plate resting on the top
weight. Inspect the entire length of the cable to ensure that it is properly seated in all
of the pulley grooves.
13c. Do not allow the use of weight plates or dumbbells to be used as a means to add
additional weight to the weight stacks. Use only the TRUE adder weight system
specifically designed for the machine.
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
S
S
A
A
F
F
E
E
T
T
Y
Y
P
P
R
R
E
E
C
C
A
A
U
U
T
T
I
I
O
O
N
N
S
S
1. Read this installation manual entirely before assembling this equipment.
2. Verify that there is adequate space surrounding this piece of equipment for safe access and
operation. Installation must meet ADA requirements for accessibility.
3. Install this piece of equipment on a solid level surface that does not deviate more than 1/8”
over a 10’ distance (or as defined and required by local building and architectural codes.)
4. TRUE strongly recommends that all equipment be anchored to the floor to prevent movement
and increase stability.
Due to the wide variation of flooring on which the unit can be installed, contact a
qualified contractor to determine an appropriate fastening system for your floor.
Use 3/8” diameter hardware (10 mm) to anchor the machine. Anchors should have a
minimum pull out force of 220 lb (110 kg) for each position.
When attaching the machine to the floor, if there is a gap between the machine foot
and the floor, do not use the anchor to remove the gap as this can cause the
machine frame to deform. Instead, place a shim between the bottom of the foot and
the floor, then tighten the anchor.
Anchoring holes are provided on the feet of the frame. All anchoring locations must
be used when anchoring the equipment to the floor.
5. DO NOT install any fitness equipment near a pool, hot tub or other damp locations. Corrosion
caused by installation in these locations can lead to premature failure of components.
6. Be sure all hardware is tight before using this machine.
7. Some assembly materials may come preassembled in the carton. Refer to Chapter 2:
Assembly Guide for instructions on disassembling assembly materials where appropriate
before beginning assembly.
SAFETY
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 7 of 30
CHAPTER 1: SAFETY INSTRUCTIONS
Strength
Rep Counter (Palladium Line)
6
M
M
A
A
I
I
N
N
T
T
E
E
N
N
A
A
N
N
C
C
E
E
S
S
A
A
F
F
E
E
T
T
Y
Y
P
P
R
R
E
E
C
C
A
A
U
U
T
T
I
I
O
O
N
N
S
S
1. Refer to the maintenance schedule table in this manual for when to perform maintenance.
2. Check the function of your machine DAILY by verifying the following:
If equipped with cables, inspect cables and end fittings for any signs of wear.
Replace if worn, frayed, or damaged with TRUE replacement components.
Verify that all adjustments are possible and carried out with ease. Make sure that
each adjustment pin inserts completely into each position without binding.
Verify that safety catches and stops are in proper working order and engaged.
Verify that the exercise is performed smoothly, free of noise, and/or binding.
If equipped with a weight stack, verify that the proper weight selector pin is in place.
3. Check the function of your machine WEEKLY by verifying the following:
Nuts, Bolts, and Fasteners: check tightness weekly. If any hardware has become
loose, retighten it, use Loctite
Threadlocker 242, or both.
Frames and Lifting Arms: Inspect weekly for integrity and function. Replace any
component at first signs of wear. Use only TRUE supplied components.
4. Replace any warning label at the first sign of wear. Labels and the facility safety sign may be
obtained from TRUE.
B
B
O
O
L
L
T
T
L
L
E
E
N
N
G
G
T
T
H
H
M
M
E
E
A
A
S
S
U
U
R
R
I
I
N
N
G
G
G
G
U
U
I
I
D
D
E
E
SAFETY
FLAT HEAD SCREW
BUTTON HEAD SCREW
HEX HEAD SCREW
SOCKET HEAD SCREW
1
23
4
5
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 8 of 30
CHAPTER 1: SAFETY INSTRUCTIONS
Strength
Rep Counter (Palladium Line)
7
IIMMPPOORRTTAANNTT
Preventative maintenance is crucial to maintaining the function and safety of this equipment. Your
facility must establish written guidelines for preventative maintenance and keep written or online
records of the maintenance performed on these products. As a minimum, the items presented in
the SAFETY section of this document and the items that follow here, should be included in your
maintenance program.
1. Cables (If equipped): inspect end fittings daily for wear. Inspect the entire length of the
cable weekly. Replace cables at the first sign of wear and on an annual basis. If the cable
tension has been adjusted, be certain that the cable nut is tight.
2. Nuts, Bolts, and Fasteners: check tightness weekly. If any hardware has become loose,
retighten and/or use Loctite
TM
brand Threadlocker 242. Be sure all hardware is tight before
using the machine.
3. Safety Catches: inspect catches, stop rods and their associated fasteners weekly. Tighten
any loose hardware and replace any components at first signs of wear.
4. Frames: sweat, disinfecting sprays and spills can lead to corrosion which may lead to
premature failure of components. Wipe all machines down with a damp cloth and dry
completely each day. This includes painted parts, chrome parts and upholstered pads.
5. Painted and chrome plated parts: use Simple Green with a dilusion of 32:1 or similar
cleaner for light dirt and grime. Use Turtle Wax Polishing Compound or a good car polish to
remove heavier dirt and grease as well as for polishing. DO NOT use solvents, lacquer
thinner, acetone or finger nail polish remover. For scuffs and marks that are not removed
by the above methods use a soft scrub cleanser. Make sure all parts are dry upon
completion.
6. Weight stack enclosures (shrouds)(If Equipped): wipe down with a damp cloth as needed.
7. Exercise instruction labels: clean with soap and water as needed.
8. Guide rods (If equipped): wipe all dirt and dust from th
e guide rods before applying a light
application of Tri-Flow
TM
or other teflon spray lubricant. Spray the Tri-Flow
TM
on a rag and
then wipe the guide rods with the rag. DO NOT use oil lubricants such as WD-40. Caution: Tri-
Flow
TM
will stain carpet and clothing.
9. Bronze bushings: check monthly for signs of wear and replace as needed.
10. Linear Bearing Shafts: wipe any accumulation of dust or other contaminants from the
shafts on a weekly basis. Apply a thin layer of a Teflon
® (PTFE) grease on a weekly basis.
TRUE recommends Magnalube
® brand.
11. When replacing any component, use only TRUE supplied parts.
12. Be sure all hardware is tight before using the machine.
Retain these instructions for future reference.
If you have any questions, do not hesitate to contact your TRUE dealer or TRUE Fitness Technology
at (800)883-8783 or service@truefitness.com.
GENERAL CARE AND MAINTENANCE
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 9 of 30
CHAPTER 1: SAFETY INSTRUCTIONS
Strength
Rep Counter (Palladium Line)
DAILY WEEKLY MONTHLY 6 MONTHS ANNUALLY
INSPECT: Cables for wear, tension, and
proper connection if equipped.
X
INSPECT: All nuts and bolts and tighten if
needed.
X
INSPECT: All anti-slip surfaces and replace
as needed.
X
INSPECT: All adjustment pins, weight stack
pins, set screws, gas shocks, snap links, and
pulleys if equipped.
X
INSPECT: All accessory bars and handles. X
INSPECT: All safety and instructional
decals.
X
INSPECT: All weight stack shields if
equipped.
X
CLEAN: Guide rods and lubricate with a
teon lubricant if equipped.
X
CLEAN: Upholstery X
LUBRICATE: Pivot bearings and linear
bearings.
X
REPLACE: Cables if equipped. X
COMMERICAL MAINTENANCE SCHEDULE
COMPLIANCES:
is equipment complies with all tness product standards. For a complete list of compliances, please visit www.
TrueFitness.com.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 10 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
SKU # Machine Description
Lower Data Cable Mounting
Bracket to Weight Stack Top Plate
Upper Data Cable Mounting
Bracket to Weight Stack Top Plate
SPL-0100 Leg Extension (mm) 2.5” (in) (mm) 4” (in)
SPL-0200 Seated Leg Curl (mm) 4” (in) (mm) 6” (in)
SPL-0300 Leg Press (mm) 5” (in) (mm) 8” (in)
SPL-0500 Triceps Extension (mm) 4“ (in) (mm) 7” (in)
SPL-0600 Biceps Curl (mm) 1.5” (in) (mm) 3” (in)
SPL-0700
Converging Shoulder
Press
(mm) 4.5” (in) (mm) 6” (in)
SPL-0900
Converging Chest
Press
(mm) 6” (in) (mm) 7.5” (in)
SPL-1000 Pec Fly/Rear Delt (mm) 6.5” (in) (mm) 8” (in)
SPL-1100
Diverging Lat
Pulldown
(mm) 12” (in) (mm) 15” (in)
SPL-1200 Diverging Seated Row (mm) 7” (in) (mm) 9” (in)
SPL-1400 Ab Crunch (mm) 2” (in) (mm) 3” (in)
REP COUNTER SENSOR MEASUREMENTS:
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 11 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 1 (Rear Shroud):
Refer to the Palladium Strength Line manual for steps to remove the Rear Shroud from the machine.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 12 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 2 (Mobile Device Holder):
Remove the Mobile Device Holder from the Upright Assembly.
Note: e hardware used to attach the Mobile Device Holder to the Upright Assembly will be used in Step 3 (Rep
Counter Mounting Bracket).
Note: e SPL-1100 and SPL-1200 are the only two Palladium Strength machines that mount the Mobile Device
Holder on the right side of the Upright Assembly.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 13 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 3A (Rep Counter Mounting Bracket):
Secure the Rep Counter Mounting Bracket to the Upright Assembly using the hardware from Step 2 (Mobile
Device Holder).
Note: For the SPL-0100, SPL-0200, SPL-0300, SPL-0500, SPL-0600, SPL-0700, SPL-0900, and SPL-1000, the Rep
Counter Mounting Bracket will be located on the le side of the Upright Assembly.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 14 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 3B (Data Cable):
Route the Data Cable through the Upright Assembly hole as shown below.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 15 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 4A (Rep Counter Faceplate):
For the SPL-0100, SPL-0200, SPL-0300, SPL-0500, SPL-0600, SPL-0700, SPL-0900, and SPL-1000, the Rep
Counter Faceplate will be oriented for mounting on the le side of the Upright Assembly.
For the SPL-1100 and SPL-1200, the Rep Counter Faceplate will be oriented for mounting on the right side of the
Upright Assembly. Refer to the images below for updating the Rep Counter Faceplate orientation if mounted on
a SPL-1100 or SPL-1200.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 16 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 4B (Rep Counter Wire Connections):
Connect the Two-Pin Female Power cable connector to the Two-Pin Male connector on the Rep counter Display
board.
Connect the Four-Pin Female Data cable connector to the Four-Pin Male connector on the Rep Counter Dispaly
board.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 17 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 5 (Rep Counter):
Secure the Rep Counter to the Mounting Bracket using the identied hardware.
Note: For the SPL-0100, SPL-0200, SPL-0300, SPL-0500, SPL-0600, SPL-0700, SPL-0900, and SPL-1000, the Rep
Counter will be located on the le side of the Upright Assembly as showb below. For the SPL-1100 and SPL-
1200, the Rep Counter will be located on the right side of the Upright Assembly.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 18 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 6 (Data Cable Mounting Brackets):
Secure the Data Cable Mounting brackets to the Data cable using the identied hardware.
Note: e picture below shows the bracket assembly orientation for the SPL-0100, SPL-0200, SPL-0300, SPL-
0500, SPL-0600, SPL-0700, SPL-0900, and SPL-1000. For the SPL-1100 and SPL-1200, the brackets will assemble
to the data cable in the opposite direction due to the Rep Counter mounting on the right side of the Upright
Assembly for those two machines.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 19 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 7A (Data Cable Mounting Brackets):
oroughly clean the area where the Data Cable Mounting Brackets will be mounted with an alcohol-based
cleaning solution.
Remove the protective lm from the adhesive tape located on the Data Cable Mounting Brackets to mount it to
the Upright Assembly as shown below.
Note: Refer to the table on pg. 10 for distance measurements between the Data Cable Mounting Brackets and
Weight Stack Top Plate.
True Fitness Technology • O’Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truetness.com
Page # 20 of 30
CHAPTER 2: ASSEMBLY GUIDE
Strength
Rep Counter (Palladium Line)
ASSEMBLY STEPS:
Step 7B (Rep Counter Sensor):
Remove the protective lm from the adhesive tape located under the Rep Counter Sensor to mount it to the
Weight Stack Top Plate as shown below.
Note: If located on a SPL-0100, SPL-0200, SPL-0300, SPL-0500, SPL-0600, SPL-0700, SPL-0900, or SPL-1000,
then mount the Rep Counter Sensor on the le side of the Weight Stack Top Plate. If located on a SPL-1100 or
SPL-1200, then mount the Rep Counter Sensor on the right side of the Weight Stack Top Plate.
Note: Conrm the Rep Counter Sensor does not touch the Reed Switches on the Data Cable Mounting Brackets
to avoid dislodging either of item. Additionally, conrm the Rep Counter Sensor mounting location enables it to
pass through the center of the magnetic switches on the Data Cable.
Lastly, perform a full rep on the machine to conrm the overall Rep Counter Assembly functions as expected
and the data displays correctly on the LED Readout screen.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30

True Fitness Palladium Strength Rep Counter User manual

Category
Fitness, gymnastics & weight training
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI