Ventamatic CX2001AMBRUPS Operating instructions

Category
Household fans
Type
Operating instructions

This manual is also suitable for

Ventamatic CX2001AMBRUPS is a roof-mounted power vent designed for attics of average size. It operates most efficiently when air intakes are located around the eaves. For larger attics, use two or more units. At least 600 sq. in. of intake is required per unit. The motor operates on 115-V.A.C. 60HZ current. See motor label for amperage. The unit is adjustable. Recommended setting is 90-110 degrees F depending on local temperatures. The fan will run as long as the attic temperature remains above the set temperature.

Ventamatic CX2001AMBRUPS is a roof-mounted power vent designed for attics of average size. It operates most efficiently when air intakes are located around the eaves. For larger attics, use two or more units. At least 600 sq. in. of intake is required per unit. The motor operates on 115-V.A.C. 60HZ current. See motor label for amperage. The unit is adjustable. Recommended setting is 90-110 degrees F depending on local temperatures. The fan will run as long as the attic temperature remains above the set temperature.

Re
a
FAIL
U
1. Do n
2. Use
t
que
s
3. Befo
out t
disc
o
the
s
4. Inst
a
acc
o
5. Whe
n
othe
r
6. The
c
affe
c
guid
e
Prot
e
and
A
1.
Thi
s
acc
e
2.
Mo
u
3.
For
g
exp
l
4.
Car
b
dra
w
is n
o
I
R
Models:
a
d all war
n
U
RE TO FOL
L
ot attempt
t
t
his unit o
n
s
tions, cont
re servicin
g
o
prevent
p
o
nnecting
m
s
ervice pan
e
a
llation wor
k
o
rdance wit
h
n
cutting o
r
r
hidden ut
i
c
ombustio
n
c
ted by this
e
line and s
a
e
ction Ass
o
A
i
r
-conditi
s
unit has
e
ssible to
nt with t
h
g
eneral v
e
l
osive ma
t
b
on mono
x
w
n into th
e
o
t properl
y
I
NSTA
L
R
OOF-
M
VXNRG, CX3
0
n
ings and
L
OW THESE
t
o use this
n
ly in the m
a
act the ma
n
g
or cleani
n
p
ower from
m
eans can
n
e
l.
k
and elect
r
h
all applic
a
r
drilling in
t
i
lities.
n
airflow n
e
unit’s ope
r
a
fety stand
a
o
ciation (N
F
o
ning Engi
n
a
n ungua
r
people o
r
h
e lowest
m
e
ntilating
t
erials an
d
x
ide is an
e
house b
y
y
maintai
n
100 WASHIN
G
PHONE: (80
L
LATI
O
M
OUN
T
0
00, VXSVR, C
X
instructi
o
INSTRUCTI
O
f
an with an
a
nner inten
n
ufacturer.
n
g this unit,
being swit
c
n
ot be lock
e
r
ical wiring
a
ble codes
t
o a wall or
e
eded for s
a
r
ation. Foll
o
a
rds such
a
F
PA), and t
h
n
eers (ASH
R
C
A
r
ded prop
e
r
animals.
m
oving p
a
use only.
d
vapors.
odorless,
y
operati
n
n
ed, or if
y
VEN
T
G
TON STRE
E
0) 433-1626 -
O
N INS
T
FOR
T
ED P
O
X
4000, VXVIP,
o
ns befor
e
O
NS COUL
D
y solid-sta
t
ded by the
switch po
w
c
hed on ac
c
e
d, securel
y
must be p
e
and stand
a
ceiling, do
a
fe operati
o
o
w the hea
t
a
s those p
u
h
e America
n
R
AE), and t
A
UTIO
N
e
ller. Do
n
a
rts at le
a
Do not u
s
colorles
s
n
g this fa
n
y
ou lack
a
T
AMATIC, LT
D
E
T, MINERAL
W
FAX: (940) 32
5
T
RUC
T
O
WER
V
CX2001, VX24
1
e
beginnin
D
RESULT IN
t
e speed c
o
manufactu
w
er off at t
h
c
identally.
y
fasten a
p
e
rformed b
y
a
rds, includ
not damag
o
n of fuel-b
u
t
ing equip
m
u
blished by
n
Society f
o
he local co
N
n
ot use in
a
st 8 feet
a
s
e to exh
a
s
gas that
n
if your f
u
a
dequate
a
D
.
W
ELLS, TX 76
0
5
-9311 - www.
b
T
IONS
V
ENTS
1
4, VX1000, C
X
n
g to inst
a
INJURY O
R
o
ntrol devic
e
rer. If you
h
h
e service
p
When serv
i
p
rominent
w
y
a qualifie
d
ing fire-rat
e
e electrical
u
rning equi
m
ent manuf
the Nation
a
o
r Heating,
de authorit
location
s
a
bove flo
o
a
ust haza
r
can kill.
u
el-burnin
g
a
ttic inta
k
0
68-0728
bvc.com
X
1000
a
ll this fan
R
EVEN DEA
T
e.
h
ave any
p
anel and l
o
i
ce
w
arning tag
d
person in
e
d constru
c
wiring and
pment ma
y
f
acture’s
a
l Fire and
Refrigerati
o
ies.
s
readily
o
r level.
r
dous or
It may be
g
equipm
e
k
e vents.
.
T
H
o
ck
to
c
tion.
y
be
o
n
e
nt
THIS
INTA
NET
LAB
E
Ste
p
Pla
c
cent
posi
t
the
h
Ste
p
Wh
e
cent
insi
d
hole
follo
w
Ste
p
Dra
w
the
r
the
h
in S
t
the
c
ROOF-MOU
N
KES ARE LO
C
FREE AIR IN
T
E
L FOR AMPE
R
p
1
c
e unit on to
p
er of the ro
o
t
ioned so th
e
h
ouse.
p
2
e
n this positi
o
erline direct
d
e the roof,
d
will be use
d
w
ing operat
i
p
3
w
a referenc
r
oof using
h
ole drilled
t
ep 2 as
c
enter.
N
TED UNIT IS
D
C
ATED AROU
N
T
AKE IS REQ
U
R
AGE.
p
of shingle
s
o
f and close
e
unit is onl
y
o
n is establi
ly between
t
d
rill a hole t
h
d
as a refer
e
i
ons.
e square 2
5
INS
T
D
ESIGNED F
O
N
D THE EAVE
U
IRED PER U
N
s
, approxim
a
to the ridge
l
y
visible on
o
shed, locat
e
t
wo rafters
a
h
rough the r
o
e
nce point f
o
5
3/8-in x 25
T
ALLATI
O
O
R ATTICS O
F
S. FOR LAR
G
N
IT. THE MO
T
a
tely in the
l
ine, but
o
ne side of
e
a
a
nd, from
o
of. This
or
the
3/8-in on
O
N INST
R
F
AVERAGE S
G
ER ATTICS,
U
T
OR OPERAT
E
Ste
p
Wit
h
rem
o
dra
w
Ste
p
Ne
x
circl
drill
e
thro
cut
l
Ste
p
Slid
e
(so
m
Pos
Ste
p
R
UCTIO
N
IZE AND OPE
U
SE TWO OR
E
S ON 115-V.
A
p
4
h
in the squa
ove shingle
s
w
n.
p
5
x
t draw a 14
e on the de
c
e
d in Step 2
ugh the de
c
l
ine.
p
6
e
the flange
m
e roofing n
ition the uni
t
p
3) to align
N
S
RATES MOS
T
MORE UNIT
S
A
.C. 60HZ CU
R
re, draw a 1
s
, nails, and
½-in diame
t
c
king. Be s
u
as a cente
r
c
king, using
t
of the unit
u
ails may ne
e
t
on the ref
e
the exhaus
t
T
EFFICIENTL
Y
S
. AT LEAST
6
R
RENT. SEE
M
7-in diamet
e
felt from th
e
t
er circle ins
u
re to use t
h
r
of this circl
e
t
he 14 ½-in
u
p under th
e
e
d to be re
m
e
rence squa
r
t
opening.
Y
WHEN AIR
6
00 SQ. IN. O
F
M
OTOR
e
r circle an
d
e
circle just
ide the 17-i
n
h
e hole
e
. Cut
circle as th
e
e
shingles
m
oved).
r
e (drawn in
n
e
Step 7
When the unit is properly located, apply a generous
amount of roofing compound between the flange
and the shingles (do not hot mop) approximately
1-in inside the perimeter of the flange and begin to
secure with nails.
Suggested nailing pattern:
Step 8
Check the installation for leakage with water from a
garden hose. Do not spay water directly into the
vent opening.
THERMOSTAT INSTALLATION
WARNING
Before wiring the thermostat, turn the power off at the breaker to avoid electrocution.
Be certain to confirm to all Local Electric Codes and Regulations.
Remove the cover from the thermostat box and use screws to attach the mounting plate to a stud.
When installing the thermostat box, use screws to attach it to the stud to prevent damage to the control.
Leave the back side of the control unobstructed to allow free air circulation behind the box.
Wire the unit to the incoming power supply according to the diagram below.
The thermostat is adjustable. Recommended setting is 90-110 degrees F depending on local
temperatures.
The fan will run as long as the attic temperature remains above the set temperature.
VENTAMATIC, LTD.
LIMITED WARRANTY
Ventamatic, Ltd. extends this warranty to the original occupying owner of the home where this product is
installed that this product will be free from defects of material or workmanship for the time period listed by
model number below:
VXNRG, CX3000 LIMITED LIFETIME
VXSVR, CX4000 LIMITED 5-Year
VXVIP, CX2001 LIMITED 2-Year
VX2414 LIMITED 2-Year
VX1000, CX1000 LIMITED 2-Yaer
No subsequent purchaser of this product or of the home in which the product is installed is entitled to the
benefits of the warranty.
Ventamatic, Ltd. will replace the defective part or component only and return the new part to you freight
prepaid. Customer must bear all other expenses incurred, including labor required for field repair or
replacement and cost of return shipping of the defective part or component to Ventamatic. Customer must
also bear the cost of replacement of any part or component and the shipping charges incurred for the
replacement and return of any part or component not covered by this warranty, including parts or components
damaged by customer.
Ventamatic, Ltd. reserves the right to demand and receive written evidence of the date of purchase before
undertaking to perform its obligations under this warranty.
YOU SHOULD, THEREFORE, RETAIN YOUR SALES
SLIP AND ATTACH IT TO YOUR WARRANTY CLAIM.
In order to obtain the replacement of a part or component, you must select one of the following methods:
A. Return to factory.
Return postage prepaid the fan or part you believe to be defective to the address below:
Ventamatic, Ltd.
100 Washington Street
Mineral Wells, TX 76067
Include your name & address and a copy of your proof of purchase or installation.
B. Return to place of purchase.
There is no informal dispute settling mechanism available in the event of a controversy involving this warranty.
Any and all implied warranties shall be limited to the duration of the express warranty set forth above. In some
states, limitations of the duration of implied warranty do not apply.
Ventamatic, Ltd. shall not be liable for incidental or consequential damages, whether direct or indirect based
upon breach of warranty, breach of contract, negligence or tort. If any suit or other action is brought against
Ventamatic by customer, Ventamatic and customer irrevocably waive the right to trial by jury.
Purchase and installation of this product constitutes acceptance of the terms of this warranty by customer.
Rev. 06/12 2012 VENTAMATIC, LTD.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Ventamatic CX2001AMBRUPS Operating instructions

Category
Household fans
Type
Operating instructions
This manual is also suitable for

Ventamatic CX2001AMBRUPS is a roof-mounted power vent designed for attics of average size. It operates most efficiently when air intakes are located around the eaves. For larger attics, use two or more units. At least 600 sq. in. of intake is required per unit. The motor operates on 115-V.A.C. 60HZ current. See motor label for amperage. The unit is adjustable. Recommended setting is 90-110 degrees F depending on local temperatures. The fan will run as long as the attic temperature remains above the set temperature.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI