Ventamatic CX1500UPS Installation guide

Category
Household fans
Type
Installation guide
Re
a
FAIL
U
1. Do n
2. Use
t
que
s
3. Befo
out t
disc
o
the
s
4. Inst
a
acc
o
5. Whe
n
othe
r
6. The
c
affe
c
guid
e
Prot
e
and
A
1.
Thi
s
acc
e
2.
Mo
u
3.
For
g
exp
l
4.
Car
b
dra
w
is n
o
I
G
a
d all war
n
U
RE TO FOL
L
ot attempt
t
t
his unit o
n
s
tions, cont
re servicin
g
o
prevent
p
o
nnecting
m
s
ervice pan
e
a
llation wor
k
o
rdance wit
h
n
cutting o
r
r
hidden ut
i
c
ombustio
n
c
ted by this
e
line and s
a
e
ction Ass
o
A
i
r
-conditi
s
unit has
e
ssible to
nt with t
h
g
eneral v
e
l
osive ma
t
b
on mono
x
w
n into th
e
o
t properl
y
I
NSTA
L
G
ABLE
Models:
V
n
ings and
L
OW THESE
t
o use this
n
ly in the m
a
act the ma
n
g
or cleani
n
p
ower from
m
eans can
n
e
l.
k
and elect
r
h
all applic
a
r
drilling in
t
i
lities.
n
airflow n
e
unit’s ope
r
a
fety stand
a
o
ciation (N
F
o
ning Engi
n
a
n ungua
r
people o
r
h
e lowest
m
e
ntilating
t
erials an
d
x
ide is an
e
house b
y
y
maintai
n
100 WASHIN
G
PHONE: (80
L
LATI
O
MOUN
V
X2500, CX250
0
instructi
o
INSTRUCTI
O
f
an with an
a
nner inten
n
ufacturer.
n
g this unit,
being swit
c
n
ot be lock
e
r
ical wiring
a
ble codes
t
o a wall or
e
eded for s
a
r
ation. Foll
o
a
rds such
a
F
PA), and t
h
n
eers (ASH
R
C
A
r
ded prop
e
r
animals.
m
oving p
a
use only.
d
vapors.
odorless,
y
operati
n
n
ed, or if
y
VEN
T
G
TON STRE
E
0) 433-1626 -
O
N INS
T
FOR
TED V
E
0
, VX2516, CX1
o
ns befor
e
O
NS COUL
D
y solid-sta
t
ded by the
switch po
w
c
hed on ac
c
e
d, securel
y
must be p
e
and stand
a
ceiling, do
a
fe operati
o
o
w the hea
t
a
s those p
u
h
e America
n
R
AE), and t
A
UTIO
N
e
ller. Do
n
a
rts at le
a
Do not u
s
colorles
s
n
g this fa
n
y
ou lack
a
T
AMATIC, LT
D
E
T, MINERAL
W
FAX: (940) 32
5
T
RUC
T
E
NTIL
A
1
600, VX2515,
C
e
beginnin
D
RESULT IN
t
e speed c
o
manufactu
w
er off at t
h
c
identally.
y
fasten a
p
e
rformed b
y
a
rds, includ
not damag
o
n of fuel-b
u
t
ing equip
m
u
blished by
n
Society f
o
he local co
N
n
ot use in
a
st 8 feet
a
s
e to exh
a
s
gas that
n
if your f
u
a
dequate
a
D
.
W
ELLS, TX 76
0
5
-9311 - www.
b
T
IONS
A
TOR
S
C
X1500
n
g to inst
a
INJURY O
R
o
ntrol devic
e
rer. If you
h
h
e service
p
When serv
i
p
rominent
w
y
a qualifie
d
ing fire-rat
e
e electrical
u
rning equi
m
ent manuf
the Nation
a
o
r Heating,
de authorit
location
s
a
bove flo
o
a
ust haza
r
can kill.
u
el-burnin
g
a
ttic inta
k
0
68-0728
bvc.com
S
a
ll this fan
R
EVEN DEA
T
e.
h
ave any
p
anel and l
o
i
ce
w
arning tag
d
person in
e
d constru
c
wiring and
pment ma
y
f
acture’s
a
l Fire and
Refrigerati
o
ies.
s
readily
o
r level.
r
dous or
It may be
g
equipm
e
k
e vents.
.
T
H
o
ck
to
c
tion.
y
be
o
n
e
nt
INSTALLATION INSTRUCTIONS
THIS GABLE-MOUNTED UNIT IS DESIGNED FOR ATTICS OF AVERAGE SIZE AND OPERATES MOST EFFICIENTLY WHEN AIR
INTAKES ARE LOCATED AROUND THE EAVES. ALTERNATIVELY, AIR INTAKE MAY BE FROM OPPOSING GABLE VENTS, BUT
NEVER FROM ROOF OR RIDGE VENTS. AT LEAST 600 SQ. IN OF NET FREE AIR INTAKE IS REQUIRED PER UNIT FOR SAFE
AND EFFICIENT OPERATION. THE MOTOR OPERATES ON 120 V, 60 HZ, A.C. CURRENT. SEE MOTOR LABEL FOR
AMPERAGE.
THIS UNIT MAY BE MOUNTED BEHIND ANY STATIC WALL VENT, OR MODELS VX1818 OR CX2121 AUTOMATIC SHUTTERS.
Step 1 Step 3
For new installation or installation behind
existing louvers, using 2 x 4 studs, frame an
opening at least 18 ¼-in square (depending on
stud spacing) on center, on the attic side of the
gable.
Step 2
Cover the opening with a square piece of
plywood, paneling, or sheetrock, at least
21 ¼-in square (depending on stud spacing).
Cut a 15-in diameter hole in the center of this
panel, to allow the shroud of the fan to enter the
hole.
It is important to block off any remaining open
vent area in the gable.
With the nuts and bolts furnished, secure the 4
mounting brackets to the shroud and then
fasten the unit to the frame.
Mounting the long side of the
L brackets with the long side
to the shroud may better fit
your installation
and also help
reduce vibration.
Also, the use of a
sound-dampening
barrier, such as rubber washers or foam
stripping will help
reduce resonance
in the walls. Seal
off any
gaps
around the
fan, in order
for the fan to
function at
maximum
efficiency
.
TIP:
MUCH OF THE PREPARATION, WIRING OF
THERMOSTAT, TESTING, AND MOUNTING TO THE
FRAME CAN BE DONE BEFORE FINAL INSTALLATION IN
THE ATTIC.
FOR INSTALLATION BEHIND TRIANGULAR GABLE VENTS
For installation on triangular gable vents, refer to steps 1-3 on the opposite page and the following
illustrations for references.
Step 1 Step 2 Step 3
THERMOSTAT INSTALLATION
WARNING
Before wiring the thermostat, turn the power off at the breaker to avoid electrocution.
Be certain to confirm to all Local Electric Codes and Regulations.
Remove the cover from the thermostat box and use screws to attach the mounting plate to a stud.
When installing the thermostat box, use screws to attach it to the stud to prevent damage to the control.
Leave the back side of the control unobstructed to allow free air circulation behind the box.
Wire the unit to the incoming power supply according to the diagram below.
The thermostat is adjustable. Recommended setting is 90-110 degrees F depending on local
temperatures.
The fan will run as long as the attic temperature remains above the set temperature.
VENTAMATIC, LTD.
LIMITED WARRANTY
Ventamatic, Ltd. extends this warranty to the original occupying owner of the home where this product is
installed that this product will be free from defects of material or workmanship for the time period listed by
model number below:
VX2500 LIMITED LIFETIME CX2500 LIMITED LIFETIME
VX2516 LIMITED 2-YEAR CX1600 LIMITED 2-YEAR
VX2515 LIMITED 2-YEAR CX1500 LIMITED 2-YEAR
No subsequent purchaser of this product or of the home in which the product is installed is entitled to the
benefits of the warranty.
Ventamatic, Ltd. will replace the defective part or component only and return the new part to you freight
prepaid. Customer must bear all other expenses incurred, including labor required for field repair or
replacement and cost of return shipping of the defective part or component to Ventamatic. Customer must
also bear the cost of replacement of any part or component and the shipping charges incurred for the
replacement and return of any part or component not covered by this warranty, including parts or components
damaged by customer.
Ventamatic, Ltd. reserves the right to demand and receive written evidence of the date of purchase before
undertaking to perform its obligations under this warranty.
YOU SHOULD, THEREFORE, RETAIN YOUR SALES
SLIP AND ATTACH IT TO YOUR WARRANTY CLAIM.
In order to obtain the replacement of a part or component, you must select one of the following methods:
A. Return to factory.
Return postage prepaid the fan or part you believe to be defective to the address below:
Ventamatic, Ltd.
100 Washington Street
Mineral Wells, TX 76067
Include your name & address and a copy of your proof of purchase or installation.
B. Return to place of purchase.
There is no informal dispute settling mechanism available in the event of a controversy involving this warranty.
Any and all implied warranties shall be limited to the duration of the express warranty set forth above. In some
states, limitations of the duration of implied warranty do not apply.
Ventamatic, Ltd. shall not be liable for incidental or consequential damages, whether direct or indirect based
upon breach of warranty, breach of contract, negligence or tort. If any suit or other action is brought against
Ventamatic by customer, Ventamatic and customer irrevocably waive the right to trial by jury.
Purchase and installation of this product constitutes acceptance of the terms of this warranty by customer.
Rev. 06/12 2012 VENTAMATIC, LTD.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Ventamatic CX1500UPS Installation guide

Category
Household fans
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI