ProFace

ZKTeco ProFace User guide

  • Hello! I am an AI chatbot trained to assist you with the ZKTeco ProFace User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the
actual product and the written information in this manual.
Quick Start Guide
ProFace X (DS)
Version: 1.0
1
1Overview
Speaker
Reset Button
Tamper Switch
Exit
button
Auxiliary
input
AUX
AL+
AL-
NC
COM
NO
BUT
GND
SEN
GND
Alarm
Lock
Sensor
GND
+12V Power
GND
INWD0
INWD1
Wiegand
In
Wiegand
Out
12V
GND
WD0
WD1
Networkinterface
RS232
RS485
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
Power
interface
8-inch Touchscreen
Near-infrared Flash
Camera
Microphone
Under-screen Card
Reading Area
Note: Not all products have the function with , the real product shall prevail.
2
3 Device Installation
①Attach the mounting template sticker to the wall, and drill holes according to the mounting
paper.
Fix the backplate on the wall using wall mounting screws.
Attach the device to the backplate.
④Fasten the device to the backplate with a security screw.
Install on the wall
1 2
4
1.5m
3
Please refer to the following recommendations for installation.
AVOID DIRECT
SUNLIGHT
AND EXPOSURE
AVOID GLASS
REFRACTION
KEEP EFFECTIVE
DISTANCE
0.3-2.5m
KEEP DISTANCE
10ft
6.5ft
window
2 Installation Environment
Install on the barrier gate
1
2
Please thread the wire through the bracket before installation.
①Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut.
Adjust the angle of the device.
3
3 Device Installation
30mm
4
4 Standalone Installation
Alarm Smoke
Detector
Lock TCP/IP
Exit Button
Door Sensor
Reader
PC
5 Door Sensor, Exit Button & Alarm Connection
Door Sensor
Alarm Power
Alarm
Detector Power
SmokeDetector
ExitButton
-
+
-+
-
+
AUX
AL+
AL-
NC
COM
NO
BUT
GND
SEN
GND
GND
NO
COM
5
6 Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally unlocked when power-on) is connected with 'NO' and 'COM' terminals, and
the NC LOCK (normally locked when power-on) is connected with 'NC' and 'COM' terminals.
Take NC Lock as an example below:
1)Device not sharing power with the lock
Normally Closed Lock
DC12V
DC12V
2)Device sharing power with the lock
+12V
GND
FR107
FR107
Normally Closed Lock
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+
DC12V
+12V
GND
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+
7 Wiegand Reader Connection
Access controller
+12V
GND
Wiegand reader
INWD0
INWD1
12V
GND
WD0
WD1
Maximum 30V 3A input.
6
8 Barrier Connection
9 RS485 Connection
Barrier gate
+12V
GND
GND
485+
485-
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
485 reader
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
Note: 485A and 485B can be connected to the Barrier gate or the 485 Reader, separately, but cannot
be connected to the gate and reader at the same time.
11 Ethernet Connection
Connect the device and computer software over an Ethernet cable. An example is shown below:
: 192.168.1.201Default IP address
: 255.255.255.0 Subnet mask
: 192.168.1.130IP address
: 255.255.255.0 Subnet mask
Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment
when connecting to ZKBioSecurity software.
Click on [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK].
10 Power Connection
12V3ADC
Recommended power supply: 12V - 3A
To share the power with other devices, use a power supply with higher current ratings.
7
ZKBioSecurity
12 UserRegistration
8
Method1: Register on the device
User Mgt.
New User
All Users
Display Style
Enroll Face
When there is no super administrator set in the device, click on to enter the menu. After setting the
super administrator, the system will request for the administrators verification before entering the
menu. For the security purpose, it is recommended to register a super administrator at the first time
you use the device.
Clickon> [User Mgt.] > [New User] to register a new user. Settings include entering user ID and
name, face, card, password and profile photo, setting user role and access control role.
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
L
Print
1
New User
User ID
Name
User Role
Face
Password
Profile Photo
Access Control Role
Normal User
Card Number
**********
Mike
Enroll Card Number
Card Number:1311129048
L
Method2: Register on ZKBioSecurity software
Please set the IP address and cloud service server address in the Comm. Menu option on the device.
9
Click [Access] > [Access Device] > [Device] > [Search Device] to search the device on the software.
When an appropriate server address and port is set on the device, the searched devices are displayed
automatically.
1.
Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level
from each dropdowns and click [OK] to add the device.
For more details, please refer to the ZKBioSecurity User Manual.
2.
3.
4.
Refresh New Delete Export Search Device Device Control Set up View and Get Device Info Communication
Search Device
Search No device found? Download Search Tools to Local Disk
Total Progress
IP Address
IP Address
Device Type Serial Number
Searched devices count:2
Number of devices added:1
MAC Address Subnet Mask Gateway Address Serial Number Device Type Set Server Operations
192.168.0.31 255.255.255.0 192.168.0.1 S*********** This device has been added
Add
192.168.10.214 255.255.255.0 192.168.1.1
XXXX000000000
XXXX000000000 ProFace X (DS)
The current systen communication port is 8088, please make sure the device is set correctly.
Step 1
Step 2
Step 3
Add
Clear Data in the Device when Adding
Device Name *
Icon Type*
Area*
Add to Level
192.168.4.18
Door
Area Name
[Clear Data in the Device when Adding] will delete data in the device (except event
record), please use with caution!
OK Cancel
Step 4
Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the
software.
Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices] to synchronize all
the data to the device including the new users.
Position
Dismissed Personnel
Card Management
Personnel ID Name
The current query conditions None
Refresh Delete
Personnel ID First Name Last Name Mobile Phone Status Create Time Operations
Delete1 Mike
1-1 50 rows per page Jump To 1 /0 Page Total of 0 records
Welcome, admin
Method 3: Register on the phone
10
Click [Personnel] > [Parameters], input ‘’http://Server address: Port’ in the QR Code UGL bar. The
software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server
address: Port/app/v1/adreg’ by the mobile phone to register users.
1.
Personnel Registration
Personnel Registration
Personnel ID
First Name
Last Name
Last Name
Mike
1
Position
Dismissed Personnel
Personnel ID Setting
The Maximum Length:
Support Letters:
Personnel ID Auto-increment:
Yes No
Yes No
15
Card Setting
The Maximum Length:
Card Format Display:
Bits(Binary)
Decimal Hexadecimal
32
Yes No
Multiple Cards per Person:
Temporary Personnel Setting
Enable Temporary Personnel Auto-audit: Yes No
Self-service Registration
QR Code URL: http://Server address:Port
Download QR code image
Yes No
Enable the declaration of health information:
Card Management
The users will be displayed in [Personnel] > [Temporary Personnel], click [Review].
2.
192.168.163.150
0.0.0.0
4370
255.255.255.0
192.168.163.1
IP Address
Subnet Mask
Gateway
DNS
TCP COMM. Port
DHCP
Display in Status Bar
Ethernet
ADMS
8081
0.0.0.0
Server mode
Enable Domain Name
Server Address
Server port
Enable Proxy Server
Cloud Server Setting
HT TPS
Clickon > [Comm.] > [Ethernet]to set the network parameters. If the TCP/IP communication of the
device is successful, the icon will be displayed in the upper right corner of the standby interface.
Clickon that is, the IP > [Comm.] > [Cloud Server Setting] to set the server address and server port,
address and port number of the server after the software is installed. If the device communicates with
the server successfully, the icon will be displayed in the upper right corner of the standby interface.
14 Ethernet and Cloud Server Settings
11
13 Access Control Settings
Access Control Options
Time Rule Settings
Holidays
Combined Verification
Anti-passback Setup
Duress Options
Access Control
Clickon > [Access Control]to enter the access control management interface and set relevant
parameters of access control.
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
Print
L
Gate Control Mode
Door Lock Delay (s)
Door Sensor Delay (s)
Door Sensor Type
Verification Mode
Door Available Time Period
Normal Open Time Period
Master Device
Auxiliary Input Configuration
Speaker Alarm
Verify Mode by RS485
Access Control Options
5
10
None
Face+Password
1
None
In
Slave Device Out
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
Print
L
12
15 Detection Management
Clickon > [Detection Management]to enter the setting interface.
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
Print
L
You can enable mask detection function, and enable the Deny Access Without Mask and the
Trigger External Alarm, the device will send an alarm prompt when the user doesn’t wear a mask,
meanwhile the user will be forbidden to access, as shown in the following figure.
1
When the Allow Unregistered People to Access is enabled, you can also set Enable Capture of
Unregistered Person to save the user photo.
Enable Mask Detection
Deny Access Without Mask
Allow Unregistered People to Access
Enable Capture of Unregistered Person
Trigger External Alarm
Clear External Alarm
External Alarm Delay(s)
Detection Management
10
Update Firmware
2
08:50
Failed to verify.
Verify:Face
User ID:1
Without Mask
08:50
Successfully verified.
Name:Mike
User ID:1
Verify:Face
Mask Detected
System
Date Time
Access Logs Settings
Temperature Mgt.
Detection Management
Device Type Settings
Security Settings
Reset
Video Intercom Parameters
Face
L
16 Multi-face Identifying Settings
Clickon > [System]> [Face] > [Face Identifying Settings] > [Identifying Mode] > [Multi-face
Identifying] to enter the setting interface.
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
Print
L
When the Multi-face Identifying is enabled, the device can perform facial recognition of multiple
people at once. For more details, please refer to the User Manual.
Face
Anti-Spoofing Settings
Flash Light Sensitivity
Face Identifying Settings
Face Algorithm
Motion Detection Sensitivity
Camera Exposure Settings
100
4
90
25
70
1:N Threshold Value
1:1 Threshold Value
Face Enrollment Threshold
Face Pitch Angle
Face Rotation Angle
Image Quality
Minimum Face Size
Identifying Mode
Face Comparison Interval(s)
Face Identifying Settings
88
30
80
1
Visible-Infra Light Hybrid Matching Mode
68
40
Multi-face Identifying
Content Mode to Display
Count to Display
Tracking Identification
Identifying Mode
User ID+Timestamp
3
13
System
Date Time
Access Logs Settings
Temperature Mgt.
Detection Management
Device Type Settings
Security Settings
Reset
Video Intercom Parameters
Face L
L
17 Video Door Phone Connection
Visitors click the on the main interface of the device to call and the phone will ring. The user can
select accept or decline the call. After the user accepting, it will enter the video door phone interface.
13
On the device, click on > [System] > [Video Intercom Parameters] > [QR Code Binding].
1.
Download and install the ZSmart APP on the phone, open the APP and add the device by scanning
the QRcode.
2.
System
Date Time
Access Logs Settings
Temperature Mgt.
Detection Management
Device Type Settings
Security Settings
Reset
Video Intercom Parameters
Face
L
18 QR Code as the Mobile Credential
On the server, choose [System] > [Authority Management] > [Client Register] to add a
registered App client.
1.
In [System] > [Basic Management] > [Parameters] of ZKBioSecurity software, set Enable QR Code
to “Yes”, and select the QR code status according to the actual situation.
2.
Open the APP, enter the IP address or domain name of the server, and its port number, scan the
Register QR-code. After the connection is successful, tap on Employee to switch to the Employee
Login screen. Enter the Employee ID and Password (Default: 123456) to login.
Tap [Mobile Credential] on the APP, and a QR code will appear. Place the phone screen right in
front of the device QR code scanner. For details, please refer to the ProFace x (DS) User Manual.
4.
3.
Note:
Place your phone within 15-50cm of the device (distance depends on the size of the phone
screen and the density of the QR code). Do not block the camera and the QR code.
For more details of Dynamic QR Code, please refer the ZKBioSecurity Mobile APP User Manual.
2.
1.
14
ZKTeco Industrial Park, No. 32, Industrial Road,
Tangxia Town, Dongguan, China.
Phone : +86 769 - 82109991
Fax : +86 755 - 89602394
www.zkteco.com
Copyright@2022 ZKTECO CO., LTD. All Rights Reserved.
/