SystemAir SR80 User manual

Type
User manual

SystemAir SR80 is a versatile air handling unit designed to provide efficient ventilation solutions for various applications. It excels in delivering a comfortable indoor climate by offering features such as:

  • Precise temperature control: SR80 allows for precise adjustment of the air temperature, ensuring a consistent and comfortable environment.

  • Energy-efficient operation: Equipped with energy-saving components, SR80 minimizes energy consumption while maintaining optimal performance.

  • Flexible installation: Its compact design and multiple mounting options make SR80 suitable for a wide range of installation scenarios, including suspended, wall-mounted, or floor-standing configurations.

SystemAir SR80 is a versatile air handling unit designed to provide efficient ventilation solutions for various applications. It excels in delivering a comfortable indoor climate by offering features such as:

  • Precise temperature control: SR80 allows for precise adjustment of the air temperature, ensuring a consistent and comfortable environment.

  • Energy-efficient operation: Equipped with energy-saving components, SR80 minimizes energy consumption while maintaining optimal performance.

  • Flexible installation: Its compact design and multiple mounting options make SR80 suitable for a wide range of installation scenarios, including suspended, wall-mounted, or floor-standing configurations.

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
Document in original language | 277318 · A001
Drain pan
Installation instructions GB
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
277318 | A001
© Copyright Systemair AB
All rights reserved
E&OE
Systemair AB reserves the rights to alter their products without notice.
This also applies to products already ordered, as long as it does not affect the previously agreed specifications.
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
277318 | A001
Contents
1 Introduction ...................................................1
1.1 Product overview ...................................1
1.2 Parts enclosed . ....... ............ ........... ........1
1.3 Intended use .........................................1
2 Installation.....................................................1
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
Introduction | 1
1 Introduction
If the water coil in Topvex SR is used as a cooler (with cold water) a drain pan must be installed.
1.1 Product overview
1.2 Parts enclosed
Drain pan, rivets to attach the drain pan, protective stickers for rivet and grommet holes.
1.3 Intended use
Place the drain pan under the water coil to collect possible condensation water.
2 Installation
Danger
Disconnect the mains power supply to the unit is before performing any maintenance or electrical work.
Warning
Beware of sharp edges. Use gloves and protective clothing.
Be aware of rotating parts even if the mains power supply is disconnected.
For all Topvex SR sizes
Remove the supply air fan for easy access.
1. Disconnect the fast coupling to the electric wire.
2. Disconnect the blue and red tubes from the supply air fan (standard
units with CAV). Blue tube is connected to the cone (1) of the fan, the
red tube is connected to measuring nipple on the wall or on the sheet
metal on the suction side.
3. Loosen the two bolts on the rail to remove the fan.
Pull out the water coil.
277318 | A001
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
2| Installation
SR20, 25, 60, 80, 100 SR35, 70
Use a drill to remove the inner coil plate.
Use a drill to remove the bottom coil bracket. Attach protective stickers over the holes. The upper coil bracket
remains in place.
277318 | A001
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
Installation | 3
SR20, 25, 60, 80, 100 SR35, 70
1
1
Remove the bottom grommet (1) from the water coil and place a protective sticker over the hole. Place the water
coil in the drain pan.
Place the inner coil plate with the coil in the drain pan.
The water coil is placed in the drain pan to ensure the placement with the upper coil bracket. Mark the drill holes
using the drain pan as a template.
277318 | A001
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
4| Installation
SR20, 25, 60, 80, 100 SR35, 70
Remove the drain pan and water coil. Drill 4,2 mm holes.
Place the water coil in the drain pan and push it in to the air handling unit.
277318 | A001
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
Installation | 5
SR20, 25, 60, 80, 100 SR35, 70
Fasten the inner plate with rivets to the upper coil
bracket.
X3
X3
Fasten the drain pan with rivets.
Put the fan in place and connect the electric wire and
tubes.
For connection to drains, follow the local demands.
277318 | A001
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Get In Touch
Call: 0845 6880112
Drain pan · Installation instructions · 277318 · en_GB · 2021-08-31 · A001
Systemair Sverige AB
Industrivägen 3
SE-739 30 Skinnskatteberg, Sweden
Phone +46 222 440 00
www.systemair.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

SystemAir SR80 User manual

Type
User manual

SystemAir SR80 is a versatile air handling unit designed to provide efficient ventilation solutions for various applications. It excels in delivering a comfortable indoor climate by offering features such as:

  • Precise temperature control: SR80 allows for precise adjustment of the air temperature, ensuring a consistent and comfortable environment.

  • Energy-efficient operation: Equipped with energy-saving components, SR80 minimizes energy consumption while maintaining optimal performance.

  • Flexible installation: Its compact design and multiple mounting options make SR80 suitable for a wide range of installation scenarios, including suspended, wall-mounted, or floor-standing configurations.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI