Tynetec ZXT475 User manual

Type
User manual
DocNo.FM0599issueDPage1
169MHzTelecareDevices
PIRMovementDetector
__________________________________________________________________________________________________________

CompatiblewithReachathomealarmsand
Adventxtwardencallsystems
Passiveinfrareddetector
WalktestLED(disabledduringnormaloperation)
Alarminterval:1or3minutes
UserreplaceableAALithiumbatteries
Lowbatterywarning
Dimensions:121mmx71mmx55mm(HxWxD)
Weight:135grams
ProductCode:ZXT475


WhatcanthePIRMovementDetectorbeusedfor?
ThePIRdetectorcanbeusedfor2differentapplications;
IntruderMonitoringifmovementisdetectedanalarmisreported
InactivityMonitoringifnomovementisdetectedwithinapresetperiodanalarmisreported
RecommendedLocation
ThePIRshouldbewallmountedathighlevel(2.1m)inthehallwaytomonitormovementbetweenrooms.
IftherearepetsinthehomethePIRshouldbeinvertedandfittedatlowlevel(1m)seePETALLEYmode.
ConditionstoAvoid
AvoidplacingitemsinfrontofthePIRdetectorwhichmayrestrictitsfieldofview
DonotexposethePIRdetectortodirectsunlightorpowerfullights
DonotexposethePIRdetectortorapidvariationintemperature
DonotexposethePIRdetectortowind,airconditioningorheating
DonotdropthePIRdetectororexposetohighvibrationorshock
TypicalToolsRequired
Becarefulwhenusingstepladdersalwaysfacethedirectionyouareworking.
Adrillisnotrequirediftheselfadhesivefixingpadisused.
Alwaysmakesurethecorrectdrillbitsandscrewdriversareused.
InstallationUsingScrewFixings
1. UndoSCREWAfromthebottomofthedetectorandremovethe
completelidassembly.
2. Drilloutthe2mostsuitableFIXINGHOLESBinsidetherearsection.
Usethisasatemplatetomarkthewall.
3. Beforedrillingthewallbesuretherearenoelectricalcables
orplumbingunderthesurface.
4. Usethescrews&plugsprovidedtofixtherearsectiontothewall
notingthecorrectorientation(seenextpageforPETALLEY).
5. Removetheinsulatingtabtoconnectthebatteries,
refitthelidandtightenthescrew. 
InstallationUsingSelfAdhesivePads
UndoSCREWAandremovethelidassembly.
Removetheinsulatingtabtoconnectthebatteries. 
Refitthelidandtightenthescrew.
Selectthebestlocationwherethewallsurfaceisclean,dryandeven.
Sticktheadhesivepadtotherearofthedetector.
Pressthedetectorfirmlyagainstthewallensuringitisstucksecurely.
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:[email protected]Web:www.tynetec.co.uk
NORMAL
ORIENTATION
UP
SCREW“A”
FIXINGHOLES“B”
DocNo.FM0599issueDPage2
PetAlleyModeUP
TopreventpetscausingfalseactivationsthePIRdetector
mustbeinvertedandfittedatlowlevel(1m). PETALLEYORIENTATION
Whenfittedinthismodeanymovementbelow FITATLOWLEVELWITHLEDATTHETOP
the1mlevelwillgoundetected
.
Resultsbasedontestsina4mx4mroom.
WalkTestMode
Toenterthewalktestmode;
1. UndothescrewandremovethePIRlid
2. Waitforabout5seconds
3. Refitthelid
4. ThefrontredLEDwillflashrapidly8times
Younowhave3minutestoperformawalktest.
TheredLEDwillflashoncewhenmovementisdetected.
NOTE:therearenoradiotransmissionsduringawalktest.
AttheendofthewalktestperiodtheredLEDwill
flashrapidly8times.
ThePIRisnowinnormaloperatingmodeand
theLEDwillNOTflashwhenmovementisdetected.
Testing&RegisteringthePIRDetector
WhenthePIRlidisremovedthetamperswitchwilloperateandtransmitanalarmsignal.Thiswillalsocheckthebatterycondition
(andreportanalarmiflow)toassistServiceEngineers.

ThetamperswitchshouldbeactivatedwhenlearningthePIRontotheReachathomealarmorAdventxtwardencallsystem.
Seepages3&4forhowtoputeachoftheseproductsinto“LearnMode”.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment‐alwaystakecareduringinstallationand
performseveraltestcalls.
DILSwitchSettings
The2wayDILswitchinsidethePIRdetectorisusedtosetthesensitivityandalarminterval;
DILSwitchNo.&Function OFF(Default) ON
SW1=PulseCount(Sensitivity) 2pulsestotrigger 3pulsestotrigger
SW2=AlarmIntervalTime 3minutes 1minute
IffalsealarmsareaproblemtrysettingDILswitch1ONtoreducethesensitivity.
AfteranactivationthePIRturnsitselfoffforthealarmintervaltimetoconservebatterypower.
Duringthealarmintervalperiodmovementisnotdetected.
Maintenance
Noroutinemaintenanceisrequired;howeverawalktestshouldbeperformedonceayeartoverifyoperation.
PIR’sarenotassusceptibletodustandcontaminationassomedetectorsbutitisstillrecommendedtocleanthemperiodically.
PIR’scanbedustedorwipedcleanwithadampcloth,neverusedetergentsorpolish.
Decorating
NeverpaintthePIRdetectoritself.
Unlikesomedetectors,PIR’sarenotsusceptibletocontamination
frompaintfumesthereforenospecialprecautionsneedtobetaken.
BatteryLife
ThePIRcontains2longlifeLithiumbatteries. Undernormaloperatingconditions
(40activations/day)thebatteriesshouldlastforupto2years.

Thebatteryconditionischeckedonceaday,ifthevoltagefallsandstaysbelowa
presetlevelfor7consecutivedaysalowbatteryalertisautomaticallytransmitted.
Anotherlowbatterycallwillnotbetransmittedfor7days,thebatteriesshould
bereplacedwithin2weeksofthefirstlowbatterywarning.
Replacementbatteries:2xAAsizeEnergizerLithiumalwaysreplaceinpairs.
Takecaretorefitthebatteriesinthecorrectpolarity.
NORMALDETECTION
PATTERN‐SIDEVIEW
PETALLEYDETECTION
PATTERN‐SIDEVIEW
DETECTIONPATTERN
TOPVIEW
DocNo.FM0599issueDPage3
RegisteringaPIRDetectorontoaReachathomealarmunit
1.PuttheReachunitintoradiodevicelearnmode…




2.ActivatethePIRdetectortamper…




3.Exitradiodevicelearnmode…




4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall.PresstheGREENbuttonontheReachunitanditwill
announceIntruderMode…Ready”.Pressthependantwithin20secondsandtheReachwillannounceEnabled”followedby
BeepBeepfor
thedurationoftheexittime.Lettheexittimeexpirethenopenthedoor,donotdisableintrudermodeonthe
Reachunit,whentheentrytimeexpiresanintruderalarmcallwillbereportedtotheControlCentre.
DeletingaPIRDetectorfromaReachathomealarmunit
Enter1670usingthekeypadontherearoftheReachunitthefrontlightwillFLASHFASTGREENandtheunitwillannounce
ProgramMode‐Ready”.
Enter#041andtheReachwillannounceDeleteRadioDevicefollowedbya
Beep”.
Enterthe8digitPIRID
tobedeleted;aftertheBeeppress#toexit.
PressthekeytoexitProgramMode;theunitwillsounda DoubleBeepandthefrontlightwillreturntoSTEADYGREEN.
The8digitIDcanbefoundonalabelinsidethebackofthePIRdetectoritwillalwaysstartwith50xxxxxx
TheinstructionsgivenaboveforthestandardReachproductalsoappliestotheReachPlus,ReachPlusGSM
andReachUltramodels.Refertotheinstructionbookletsprovidedwiththeseproductsformoreinformation
onprogramming/testingradiodevicesandsetup/operatingintrudermode.

Trigger
Radio
Device
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounceTriggerRadioDevice”.
Younowhave1minutetoactivatethePIRdetector.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
isbackinnormaloperatingmode.
UndothescrewandremovethePIRlidfromitsbasetoactivatethe
tamperswitch.
TheReachwillannounceMovementSensor”.
RefitthePIRlid.
DocNo.FM0599issueDPage4
RegisteringaPIRDetectorontoanAdventxtwardencallsystem
1.PuttheAdventxtsystemintoradiodevicelearnmode…


 

2.ActivatethePIRdetectortamper…




3.ExittheAdventxtsystemradiodevicelearnmode…




4.UsingtheManager’sDECTtelephonesettheflatintointrudermode;presstheLINEkeyandwaitfortheReadyprompt,enter
3007thenentertheflatnumbertohaveintrudermode
enabledfollowedbythekey,thenpresstheLINEkeytoclearthe
connection.Openthedoorandcheckanintruderalarmcallisreportedonthewardencallsystem.Toresetintrudermode;enter
3008thenentertheflatnumbertobedisabledfollowedbythekey,thenpresstheLINEkeytocleartheconnection.
DeletingaPIRDetectorfromanAdventxtwardencallsystem
PresstheLINEkeyandwaitfortheReadyprompt.
Enter5001followedbythekey.
EntertheflatnumberthePIRisbeingdeletedfromfollowedbythekey.
ActivatethetamperswitchonthePIRtobedeleted.
WaitforthePendantDisabledEnterFlatprompt.
Pressthe#keyandwaitfortheReadyprompt,thenpresstheLINEkeytocleartheconnection.
RefertotheAdventxtoperatorsmanual(DocNo.FM0420)providedwiththewardencallsystemformore
informationonprogramming/testingradiodevicesandoperationoftheintrudermode.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservetherighttochangeproductspecificationswithoutnotice.
IfanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactTynetec’scustomersupportdepton01670352371.
UsingtheManager’sDECTtelephone;
PresstheLINEkeyandwaitfortheReadyprompt.
Enter5000followedbythekey.
EntertheflatnumberthePIRisbeinginstalledinfollowedbythekey.
Younowhave1minutetoactivatethePIRdetector.
Ready”
UsingtheManager’sDECTtelephone;
Pressthe#keyandwaitfortheReadyprompt.
PresstheLINEkeytoclearthe connectionandthewardencallsystemis
nowbackinnormaloperatingmode.
UndothescrewandremovethePIRlidfromitsbasetoactivatethe
tamperswitch.
WaitfortheEnterLocationCodepromptthenpress0(nolocation)
followedbythekey.
WaitforthePendantEnabledEnterFlatprompt.
RefitthePIRlid.
Ready”